Bioimpedance Measurement of Knee Injuries Using Bipolar Electrode Configuration

被引:6
|
作者
Ye, Xuanjie [1 ]
Wu, Lexi [2 ]
Mao, Kaining [1 ]
Feng, Yiwei [1 ]
Li, Jiajun [1 ]
Ning, Lei [3 ]
Chen, Jie [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[2] Zhejiang Univ, Sch Med, Hangzhou 310030, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Orthopaed Surg, Med Coll, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Bioimpedance; Electrodes; Injuries; Knee; Current measurement; Biomedical measurement; Impedance; bipolar electrode configuration; knee injuries; machine learning; portable device; BIOELECTRICAL-IMPEDANCE; ELECTRICAL BIOIMPEDANCE; DRY ELECTRODES; EDEMA; BODY; INFLAMMATION; LYMPHEDEMA; MANAGEMENT; DIAGNOSIS; SEVERITY;
D O I
10.1109/TBCAS.2022.3200355
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p approximate to 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.
引用
收藏
页码:962 / 971
页数:10
相关论文
共 50 条
  • [41] CONTINUOUS VOLTAGE PULSING USING A ROTATING BIPOLAR ELECTRODE
    NADEBAUM, PR
    FAHIDY, TZ
    NATURE-PHYSICAL SCIENCE, 1973, 241 (106): : 45 - 46
  • [42] Regenerable bipolar electrochemiluminescence device using glassy carbon bipolar electrode, stainless steel driving electrode and cold patch
    Yuan, Fan
    Qi, Liming
    Fereja, Tadesse Haile
    Snizhko, Dmytro V.
    Liu, Zhongyuan
    Zhang, Wei
    Xu, Guobao
    ELECTROCHIMICA ACTA, 2018, 262 : 182 - 186
  • [43] Effective measurement of knee alignment using AP knee radiographs
    Colebatch, Alexandra N.
    Hart, Deborah J.
    Zhai, Guangju
    Williams, F. M.
    Spector, Tim D.
    Arden, Nigel K.
    KNEE, 2009, 16 (01): : 42 - 45
  • [44] Current-voltage characteristics of bipolar corona discharge in multi-needle electrode configuration
    Chen, Hai-Feng
    Zhu, Yi-Min
    Su, Peng-Hao
    Yang, Jia-Yuan
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (10): : 92 - 95
  • [45] Editorial Commentary: The Measurement of Knee Laxity: Instrumented Measurement and Stress Radiography for Anterior Cruciate Ligament Injuries
    Kircher, Jorn
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (06): : 1733 - 1735
  • [46] Performance evaluation of the electrode configuration in bioelectrical impedance analysis for visceral fat measurement
    Kim, Kwangsoo
    Lee, Mi-hee
    Kim, Jungchae
    Jung, Seok Myung
    Jee, Sun Ha
    Yoo, Sun K.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 892 - +
  • [47] Bipolar measurement matrix using chaotic sequence
    Gan, Hongping
    Xiao, Song
    Zhang, Tao
    Liu, Feng
    COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2019, 72 : 139 - 151
  • [48] Monitoring Fluid Shifts During Haemodialysis Using Local Tissue Bioimpedance Measurement
    Al-Surkhi, Omar I.
    Riu, P. J.
    Vazquez, F.
    Ibeas, J.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1334 - 1338
  • [49] Concentric Bipolar Active Electrode for Noninvasive Biopotential Measurement in Autonomic Nervous System
    Hasegawa, S.
    Aoki, Y.
    Wada, S.
    Ueno, A.
    Fukuoka, Y.
    Cauwenberghs, G.
    Shimizu, Y.
    Nishimura, N.
    Iwase, S.
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [50] Automated Detection and Evaluation of Swallowing Using a Combined EMG/Bioimpedance Measurement System
    Schultheiss, Corinna
    Schauer, Thomas
    Nahrstaedt, Holger
    Seidl, Rainer O.
    SCIENTIFIC WORLD JOURNAL, 2014,