Cell constant studies of bipolar and tetrapolar electrode systems for impedance measurement

被引:19
|
作者
Ma, Hanbin [1 ]
Su, Yang [1 ]
Nathan, Arokia [1 ]
机构
[1] Univ Cambridge, Div Elect, Dept Engn, 9 JJ Thomson Ave, Cambridge CB3 0FA, England
来源
关键词
Bipolar and tetrapolar electrodes; Impedance sensor; Planar thin-film electrodes; Cell constant; Electrode polarisation; LABEL-FREE; MICROELECTRODE; HYBRIDIZATION; POLARIZATION; OPTIMIZATION; BIOSENSORS; SENSORS;
D O I
10.1016/j.snb.2015.07.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In comparison to the bipolar or two-electrode system, the tetrapolar or four-electrode arrangement is a well-known technique to reduce electrode polarisation just as effectively. However, recent studies have showed that phenomena such as negative sensitivity and multiple current paths can compromise the advantages of the tetrapolar electrode arrangement, thereby potentially limiting its applications. This paper reveals a novel method to evaluate the performance of the different electrode systems in which the concept of cell constant is extended to an impedance measurement system. We employ it as a standardised parameter to quantitatively analyse planar electrode systems in bipolar and tetrapolar measurement modes. Indeed, the cell constant is a key parameter in conductivity sensors to evaluate electrodes designs since it is independent of any readout electronics. A comparison of measurement modes using finite element methods (FEM) simulations and measurements for sodium chloride solutions is presented. While the cell constant of the bipolar electrode system is one order of magnitude greater than that of the tetrapolar arrangement, it shows large discrepancy over the measured frequency range. In contrast, despite the existence of measurement errors, the tetrapolar arrangement yields a uniform cell constant and good agreement with the simulations. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 50 条
  • [1] NEW ELECTRODE HARNESS FOR BASIC AND PULSATILE IMPEDANCE STUDIES OF HEAD BY TETRAPOLAR SYSTEMS
    NYBOER, J
    GUARNERI, D
    PHYSIOLOGIA BOHEMOSLOVACA, 1971, 20 (04): : 396 - &
  • [2] Application of Tetrapolar Electrode Systems in Electrical Impedance Measurements
    A. V. Kobelev
    S. I. Shchukin
    S. Leonhardt
    Biomedical Engineering, 2019, 52 : 383 - 386
  • [3] Application of Tetrapolar Electrode Systems in Electrical Impedance Measurements
    Kobelev, A., V
    Shchukin, S., I
    Leonhardt, S.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2019, 52 (06): : 383 - 386
  • [4] Optimization of Bipolar and Tetrapolar Impedance Biosensors
    Kassanos, Panagiotis
    Demosthenous, Andreas
    Bayford, Richard H.
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 1512 - 1515
  • [5] CELL CONSTANT OF THE TETRAPOLAR CONDUCTIVITY CELL
    LITTWITZ, C
    RAGHEB, T
    GEDDES, LA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (06) : 587 - 590
  • [6] TETRAPOLAR ELECTRODE SYSTEM FOR MEASURING PHYSIOLOGICAL EVENTS BY IMPEDANCE
    RAGHEB, AO
    GEDDES, LA
    BOURLAND, JD
    TACKER, WA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (01) : 115 - 117
  • [7] Bipolar and tetrapolar transfer impedance measurements from volume conductor
    Brown, BH
    Wilson, AJ
    Bertemes, P
    ELECTRONICS LETTERS, 2000, 36 (25) : 2060 - 2062
  • [8] Comparison of bipolar and tetrapolar impedance techniques for assessing fat mass
    Dittmar, M
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2004, 16 (05) : 593 - 597
  • [9] ELECTRODE SYSTEM FOR TETRAPOLAR ELECTRICAL-IMPEDANCE PLETHYSMOGRAPHY OF FINGER
    MONTGOMERY, LD
    MOODY, DL
    WILLIAMS, BA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1977, 24 (04) : 385 - 386
  • [10] Measurement and modelling the sensitivity of tetrapolar transfer impedance measurements
    Naydenova, E.
    Cavendish, S.
    Wilson, A. J.
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (10) : 1090 - 1099