Human response to five designs of personalized ventilation

被引:75
|
作者
Kaczmarczyk, J [1 ]
Melikov, A
Bolashikov, Z
Nikolaev, L
Fanger, PO
机构
[1] Tech Univ Denmark, Dept Mech, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
[2] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, Gliwice, Poland
来源
HVAC&R RESEARCH | 2006年 / 12卷 / 02期
关键词
D O I
10.1080/10789669.2006.10391184
中图分类号
O414.1 [热力学];
学科分类号
摘要
Human response to five different air terminal devices (ATDs) for a personalized ventilation system (PVS) was studied in an experimental office under well-defined conditions. A group of 30 human subjects assessed air quality and rated their thermal comfort and perception of draft. Two temperature levels, 23 degrees C and 26 degrees C, and two background levels of air quality in the office, high and low, were studied during the experiments. Under all conditions the personalized ventilation system provided outdoor air at a temperature of 20 degrees C. All PVSs allowed for individual control of the airflow rate as well as for adjustments of the supply air direction. Results showed that all ATDs studied significantly improved perceived air quality at the workstation. The greatest improvement was obtained when the pollution level and the temperature in the office were high. The thermal environment created with all systems was assessed as acceptable. Subjects were able to improve thermal comfort with all ATDs studied. The subjects identified which of the tested ATDs they preferred.
引用
收藏
页码:367 / 384
页数:18
相关论文
共 50 条
  • [1] Human response to personalized ventilation and mixing ventilation
    Kaczmarczyk, J
    Melikov, A
    Fanger, PO
    INDOOR AIR, 2004, 14 : 17 - 29
  • [2] Performance of ductless personalized ventilation in conjunction with displacement ventilation: Physical environment and human response
    Dalewski, Mariusz
    Melikov, Arsen K.
    Vesely, Michal
    BUILDING AND ENVIRONMENT, 2014, 81 : 354 - 364
  • [3] Influence of sinusoidal airflow and airflow distance on human thermal response to a personalized ventilation system
    Xie, Yongxin
    Fu, Sauchung
    Wu, Chili
    Chao, Christopher Y. H.
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (03) : 317 - 330
  • [4] The effect of human breathing on the effectiveness of intermittent personalized ventilation coupled with mixing ventilation
    Katramiz, Elvire
    Al Assaad, Douaa
    Ghaddar, Nesreen
    Ghali, Kamel
    BUILDING AND ENVIRONMENT, 2020, 174 (174)
  • [5] Personalized ventilation
    Melikov, AK
    INDOOR AIR, 2004, 14 : 157 - 167
  • [6] Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation?
    Alsaad, Hayder
    Voelker, Conrad
    INDOOR AIR, 2021, 31 (01) : 99 - 111
  • [7] Alternative personalized ventilation
    Kalmar, Ferenc
    Kalmar, Tuende
    ENERGY AND BUILDINGS, 2013, 65 : 37 - 44
  • [8] Coupling CFD and human body thermoregulation model for the assessment of personalized ventilation
    Gao, NP
    Niu, JL
    Zhang, H
    HVAC&R RESEARCH, 2006, 12 (03): : 497 - 518
  • [9] Performance of personalized ventilation in conjunction with mixing and displacement ventilation
    Cermak, R
    Melikov, AK
    Forejt, L
    Kovar, O
    HVAC&R RESEARCH, 2006, 12 (02): : 295 - 311
  • [10] CFD study on micro-environment around human body and personalized ventilation
    Gao, NP
    Niu, JL
    BUILDING AND ENVIRONMENT, 2004, 39 (07) : 795 - 805