Human response to five designs of personalized ventilation

被引:75
|
作者
Kaczmarczyk, J [1 ]
Melikov, A
Bolashikov, Z
Nikolaev, L
Fanger, PO
机构
[1] Tech Univ Denmark, Dept Mech, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
[2] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, Gliwice, Poland
来源
HVAC&R RESEARCH | 2006年 / 12卷 / 02期
关键词
D O I
10.1080/10789669.2006.10391184
中图分类号
O414.1 [热力学];
学科分类号
摘要
Human response to five different air terminal devices (ATDs) for a personalized ventilation system (PVS) was studied in an experimental office under well-defined conditions. A group of 30 human subjects assessed air quality and rated their thermal comfort and perception of draft. Two temperature levels, 23 degrees C and 26 degrees C, and two background levels of air quality in the office, high and low, were studied during the experiments. Under all conditions the personalized ventilation system provided outdoor air at a temperature of 20 degrees C. All PVSs allowed for individual control of the airflow rate as well as for adjustments of the supply air direction. Results showed that all ATDs studied significantly improved perceived air quality at the workstation. The greatest improvement was obtained when the pollution level and the temperature in the office were high. The thermal environment created with all systems was assessed as acceptable. Subjects were able to improve thermal comfort with all ATDs studied. The subjects identified which of the tested ATDs they preferred.
引用
收藏
页码:367 / 384
页数:18
相关论文
共 50 条
  • [41] Molecular Response of the Human Diaphragm on Different Modes of Mechanical Ventilation
    Dermitzaki, Despina
    Tzortzaki, Eleni
    Soulitzis, Nikolaos
    Neofytou, Eirini
    Prinianakis, Georgios
    Matalliotakis, Ioannis
    Askitopoulou, Helen
    Siafakas, Nikolaos M.
    RESPIRATION, 2013, 85 (03) : 228 - 235
  • [42] CFD optimization of jet fan ventilation in a car park by fractional factorial designs and response surface methodology
    Eero Immonen
    Building Simulation, 2016, 9 : 53 - 61
  • [43] CFD optimization of jet fan ventilation in a car park by fractional factorial designs and response surface methodology
    Immonen, Eero
    BUILDING SIMULATION, 2016, 9 (01) : 53 - 61
  • [44] Generating personalized business card designs from imagess
    Antunes, Nuno
    Ferreira, Joao Carlos
    Cardoso, Elsa
    MULTIMEDIA TOOLS AND APPLICATIONS, 2022, 81 (18) : 25051 - 25073
  • [45] Generating personalized business card designs from images
    Nuno Antunes
    João Carlos Ferreira
    Elsa Cardoso
    Multimedia Tools and Applications, 2022, 81 : 25051 - 25073
  • [46] Compound Optimum Designs for Clinical Trials in Personalized Medicine
    Duarte, Belmiro P. M.
    Atkinson, Anthony C.
    Pedrosa, David
    van Munster, Marlena
    MATHEMATICS, 2024, 12 (19)
  • [47] Modeling the performance of personalized ventilation under different conditions of room air and personalized air
    Gao, NP
    Niu, JL
    HVAC&R RESEARCH, 2005, 11 (04): : 587 - 602
  • [48] Chasing Mendel: five questions for personalized medicine
    Joyner, Michael J.
    Prendergast, Franklyn G.
    JOURNAL OF PHYSIOLOGY-LONDON, 2014, 592 (11): : 2381 - 2388
  • [49] VENTILATION HETEROGENEITY IN RESPONSE TO MECHANICAL VENTILATION
    Preissner, M.
    Yen, S.
    Bennett, E.
    Fouras, A.
    Dargaville, P.
    Zosky, G.
    Dubsky, S.
    RESPIROLOGY, 2021, 26 : 30 - 30
  • [50] Personalized response prediction
    Thoma, Clemens
    NATURE REVIEWS GASTROENTEROLOGY & HEPATOLOGY, 2018, 15 (11) : 657 - 657