Human response to five designs of personalized ventilation

被引:75
|
作者
Kaczmarczyk, J [1 ]
Melikov, A
Bolashikov, Z
Nikolaev, L
Fanger, PO
机构
[1] Tech Univ Denmark, Dept Mech, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
[2] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, Gliwice, Poland
来源
HVAC&R RESEARCH | 2006年 / 12卷 / 02期
关键词
D O I
10.1080/10789669.2006.10391184
中图分类号
O414.1 [热力学];
学科分类号
摘要
Human response to five different air terminal devices (ATDs) for a personalized ventilation system (PVS) was studied in an experimental office under well-defined conditions. A group of 30 human subjects assessed air quality and rated their thermal comfort and perception of draft. Two temperature levels, 23 degrees C and 26 degrees C, and two background levels of air quality in the office, high and low, were studied during the experiments. Under all conditions the personalized ventilation system provided outdoor air at a temperature of 20 degrees C. All PVSs allowed for individual control of the airflow rate as well as for adjustments of the supply air direction. Results showed that all ATDs studied significantly improved perceived air quality at the workstation. The greatest improvement was obtained when the pollution level and the temperature in the office were high. The thermal environment created with all systems was assessed as acceptable. Subjects were able to improve thermal comfort with all ATDs studied. The subjects identified which of the tested ATDs they preferred.
引用
收藏
页码:367 / 384
页数:18
相关论文
共 50 条
  • [31] A simplified combined displacement and personalized ventilation model
    Alain, Makhoul
    Kamel, Ghali
    Nesreen, Ghaddar
    HVAC&R RESEARCH, 2012, 18 (04): : 737 - 749
  • [32] Insights on critical parameters and conditions for personalized ventilation
    Zhai, Zhiqiang
    Metzger, Ian Dominic
    SUSTAINABLE CITIES AND SOCIETY, 2019, 48
  • [33] Operation Testing of an Advanced Personalized Ventilation System
    Csaky, Imre
    Kalmar, Tunde
    Kalmar, Ferend
    ENERGIES, 2019, 12 (09)
  • [34] Assessment of Thermal Comfort Using Personalized Ventilation
    Bogdan, Anna
    Chludzinska, Marta
    HVAC&R RESEARCH, 2010, 16 (04): : 529 - 542
  • [35] Five Economies of Weltliteratur Designs for Circulation
    Hites, Sandor
    JOURNAL OF WORLD LITERATURE, 2022, 7 (02) : 202 - 233
  • [36] On directed designs with block size five
    Bowler A.
    Grannell M.
    Griggs T.S.
    Quinn K.A.S.
    Journal of Geometry, 2000, 67 (1-2) : 50 - 60
  • [37] Five designs for Hudson Park revealed
    McKeough, Tim
    ARCHITECTURAL RECORD, 2008, 196 (11) : 42 - 42
  • [38] Individual control of a personalized ventilation system integrated with an ambient mixing ventilation system
    Chen, Yixing
    Raphael, Benny
    Sekhar, S. C.
    HVAC&R RESEARCH, 2012, 18 (06): : 1136 - 1152
  • [39] Performance of intermittent personalized ventilation assisting Mixing ventilation in the presence of indoor disturbance
    Al-Assad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2019, 2019,
  • [40] Performance of "ductless" personalized ventilation in conjunction with displacement ventilation: Impact of intake height
    Halvonova, Barbora
    Melikov, Arsen K.
    BUILDING AND ENVIRONMENT, 2010, 45 (04) : 996 - 1005