Human response to personalized ventilation and mixing ventilation

被引:151
|
作者
Kaczmarczyk, J [1 ]
Melikov, A [1 ]
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Lyngby, Denmark
关键词
individual control; personalized ventilation; office; perceived air quality; SBS symptoms; thermal comfort;
D O I
10.1111/j.1600-0668.2004.00300.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The response of 60 human subjects to a personalized ventilation system (PVS), providing control of positioning of the air terminal device and the airflow rate, was compared with the response to mixing ventilation (MV). Perceived air quality, thermal comfort, intensity of Sick Building Syndrome symptoms and performance of subjects were studied during 3 h 45 min exposures. In case of MV alone the room air temperature was 23degreesC and 26degreesC. The PVS supplied outdoor air at 23degreesC or 20degreesC or recirculated room air at 23degreesC when the room temperature was 23degreesC, and outdoor air at 20degreesC when the room temperature was 26degreesC. The PVS providing outdoor air improved perceived air quality and decreased SBS symptoms compared to MV alone and when the room air was re-circulated through the PVS. The percentage dissatisfied with air quality, 3 min after initial occupancy, decreased from 22% with MV to 7% with PVS; and from 49% to 20%, at room temperatures 23degreesC and 26degreesC, respectively. Over time, these differences in percentage dissatisfied decreased markedly. Headache and decreased ability to think clearly were reported as least intense when the PVS supplied outdoor air at 20degreesC, while the most intense symptoms occurred with MV. PVS increased self-estimated performance.
引用
收藏
页码:17 / 29
页数:13
相关论文
共 50 条
  • [1] The effect of human breathing on the effectiveness of intermittent personalized ventilation coupled with mixing ventilation
    Katramiz, Elvire
    Al Assaad, Douaa
    Ghaddar, Nesreen
    Ghali, Kamel
    BUILDING AND ENVIRONMENT, 2020, 174 (174)
  • [2] Performance of personalized ventilation in conjunction with mixing and displacement ventilation
    Cermak, R
    Melikov, AK
    Forejt, L
    Kovar, O
    HVAC&R RESEARCH, 2006, 12 (02): : 295 - 311
  • [3] Human response to five designs of personalized ventilation
    Kaczmarczyk, J
    Melikov, A
    Bolashikov, Z
    Nikolaev, L
    Fanger, PO
    HVAC&R RESEARCH, 2006, 12 (02): : 367 - 384
  • [4] Performance of ductless personalized ventilation in conjunction with displacement ventilation: Physical environment and human response
    Dalewski, Mariusz
    Melikov, Arsen K.
    Vesely, Michal
    BUILDING AND ENVIRONMENT, 2014, 81 : 354 - 364
  • [5] Individual control of a personalized ventilation system integrated with an ambient mixing ventilation system
    Chen, Yixing
    Raphael, Benny
    Sekhar, S. C.
    HVAC&R RESEARCH, 2012, 18 (06): : 1136 - 1152
  • [6] Performance of intermittent personalized ventilation assisting Mixing ventilation in the presence of indoor disturbance
    Al-Assad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2019, 2019,
  • [7] Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation
    Al Assaad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    BUILDING AND ENVIRONMENT, 2019, 160
  • [8] Personalized ventilation
    Melikov, AK
    INDOOR AIR, 2004, 14 : 157 - 167
  • [9] Low-mixing coaxial nozzle for effective personalized ventilation
    Makhoul, Alain
    Ghali, Kamel
    Ghaddar, Nesreen
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (02) : 225 - 243
  • [10] Mixing ventilation coupled with personalized sinusoidal ventilation: Optimal frequency and flow rate for acceptable air quality
    Al Assaad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    Habchi, Carine
    ENERGY AND BUILDINGS, 2017, 154 : 569 - 580