Human response to personalized ventilation and mixing ventilation

被引:151
|
作者
Kaczmarczyk, J [1 ]
Melikov, A [1 ]
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Lyngby, Denmark
关键词
individual control; personalized ventilation; office; perceived air quality; SBS symptoms; thermal comfort;
D O I
10.1111/j.1600-0668.2004.00300.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The response of 60 human subjects to a personalized ventilation system (PVS), providing control of positioning of the air terminal device and the airflow rate, was compared with the response to mixing ventilation (MV). Perceived air quality, thermal comfort, intensity of Sick Building Syndrome symptoms and performance of subjects were studied during 3 h 45 min exposures. In case of MV alone the room air temperature was 23degreesC and 26degreesC. The PVS supplied outdoor air at 23degreesC or 20degreesC or recirculated room air at 23degreesC when the room temperature was 23degreesC, and outdoor air at 20degreesC when the room temperature was 26degreesC. The PVS providing outdoor air improved perceived air quality and decreased SBS symptoms compared to MV alone and when the room air was re-circulated through the PVS. The percentage dissatisfied with air quality, 3 min after initial occupancy, decreased from 22% with MV to 7% with PVS; and from 49% to 20%, at room temperatures 23degreesC and 26degreesC, respectively. Over time, these differences in percentage dissatisfied decreased markedly. Headache and decreased ability to think clearly were reported as least intense when the PVS supplied outdoor air at 20degreesC, while the most intense symptoms occurred with MV. PVS increased self-estimated performance.
引用
收藏
页码:17 / 29
页数:13
相关论文
共 50 条
  • [41] A comparative experimental study on the performance of mixing ventilation and stratum ventilation for space heating
    Kong, Xiangfei
    Xi, Chang
    Li, Han
    Lin, Zhang
    BUILDING AND ENVIRONMENT, 2019, 157 : 34 - 46
  • [42] Ventilation and energy performance of partitioned indoor spaces under mixing and displacement ventilation
    Ahn, Hyeunguk
    Rim, Donghyun
    Lo, L. James
    BUILDING SIMULATION, 2018, 11 (03) : 561 - 574
  • [43] GAS MIXING VERSUS UNEVEN VENTILATION
    TROQUET, J
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1974, 82 (02): : 245 - 250
  • [44] CFD study on micro-environment around human body and personalized ventilation
    Gao, NP
    Niu, JL
    BUILDING AND ENVIRONMENT, 2004, 39 (07) : 795 - 805
  • [45] A simplified combined displacement and personalized ventilation model
    Alain, Makhoul
    Kamel, Ghali
    Nesreen, Ghaddar
    HVAC&R RESEARCH, 2012, 18 (04): : 737 - 749
  • [46] Insights on critical parameters and conditions for personalized ventilation
    Zhai, Zhiqiang
    Metzger, Ian Dominic
    SUSTAINABLE CITIES AND SOCIETY, 2019, 48
  • [47] Operation Testing of an Advanced Personalized Ventilation System
    Csaky, Imre
    Kalmar, Tunde
    Kalmar, Ferend
    ENERGIES, 2019, 12 (09)
  • [48] Assessment of Thermal Comfort Using Personalized Ventilation
    Bogdan, Anna
    Chludzinska, Marta
    HVAC&R RESEARCH, 2010, 16 (04): : 529 - 542
  • [49] Ventilation shutdown Response
    Baysinger, Angela
    Senn, Michael
    Gebhardt, Jordan
    Rademacher, Christopher
    Pairis-Garcia, Monique
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2021, 259 (10): : 1103 - 1104
  • [50] Innovative High-Induction Air Diffuser for Enhanced Air Mixing in Vehicles and Personalized Ventilation Applications
    Bode, Florin Ioan
    Joldos, Titus Otniel
    Sirbu, Gabriel Mihai
    Danca, Paul
    Cosoiu, Costin
    Nastase, Ilinca
    ENERGIES, 2024, 17 (12)