Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [41] REGIONAL BLOOD-FLOW MEASUREMENT WITH PULSED DOPPLER FLOWMETER IN CONSCIOUS RAT
    HAYWOOD, JR
    SHAFFER, RA
    FASTENOW, C
    FINK, GD
    BRODY, MJ
    AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02): : H273 - H278
  • [42] CONTINUOUS MEASUREMENT OF RAT GASTRIC BLOOD-FLOW USING DOPPLER FLOWMETER
    KOERFER, J
    BAUERFEIND, P
    ARMSTRONG, D
    BLUM, AL
    AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (04): : G686 - G692
  • [43] OBSERVATIONS OF COCHLEAR BLOOD-FLOW DYNAMICS USING THE LASER DOPPLER FLOWMETER
    KAWAKAMI, M
    MAKIMOTO, K
    NAKAJIMA, T
    TAKAHASHI, H
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1989, 246 (03): : 147 - 150
  • [44] ENDOSCOPIC MEASUREMENT OF GASTRIC-MUCOSAL BLOOD-FLOW BY LASER DOPPLER FLOWMETER IN PATIENTS WITH LIVER-CIRRHOSIS
    NISHIWAKI, H
    ASAI, T
    SATAKE, K
    SOWA, M
    UMEYAMA, K
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1989, 4 : 83 - 84
  • [45] Choroidal blood flow measured with a new confocal compact laser Doppler flowmeter
    Geiser, MH
    Riva, CE
    Diermann, U
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 214 (05) : 285 - 287
  • [46] A NEW LASER DOPPLER FLOWMETER PROTOTYPE FOR MICROCIRCULATION SKIN DEPTH MONITORING In Vitro Validation and In Vivo Preliminar Results
    Figueiras, Edite
    Campos, Rita
    Oliveira, Ricardo
    Requicha Ferreira, Luis F.
    Humeau-Heurtier, Anne
    BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, : 154 - 159
  • [47] INDIRECT BLOOD PRESSURE MEASUREMENT BY DOPPLER IN NEWBORNS
    RASHMI, A
    GUHA, DK
    JAIN, KK
    KISHORE, P
    INDIAN PEDIATRICS, 1974, 11 (11): : 729 - 733
  • [48] Laser Doppler measurement of blood velocity in microvessels
    Cochrane, T.
    Earnshaw, J.C.
    Lover, A.H.G.
    Medical and Biological Engineering and Computing, 1981, 19 (05): : 589 - 596
  • [49] The usefulness of a laser Doppler in the measurement of the blood pressures
    de Graaff, JC
    Ubbink, DT
    Legemate, DA
    de Haan, RJ
    Jacobs, MJHM
    JOURNAL OF VASCULAR SURGERY, 2000, 32 (06) : 1172 - 1179
  • [50] COLOSTOMY BLOOD FOR MEASUREMENT BY LASER DOPPLER VELOCIMETRY
    BILLINGS, PJ
    ANGIOLOGY, 1985, 36 (08) : 583 - 583