Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [21] Laser reflectance oximetry and Doppler flowmetry in assessment of complex physiological parameters of cutaneous blood microcirculation
    Dunaev, Andrey V.
    Sidorov, Victor V.
    Stewart, Neil A.
    Sokolovski, Sergei G.
    Rafailov, Edik U.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [22] MEASUREMENT OF VELOCITY PROFILES OF RED BLOOD-CELLS IN MICROCIRCULATION BY LASER DOPPLER ANEMOMETRY (LDA)
    EINAV, S
    BERMAN, HJ
    FUHRO, RL
    DIGIOVANNI, PR
    FINE, S
    FRIDMAN, JD
    BIORHEOLOGY, 1975, 12 (3-4) : 207 - 210
  • [23] APPLICATION AND IN-SITU CALIBRATION OF A PULSED-DOPPLER FLOWMETER FOR BLOOD-FLOW MEASUREMENT IN CRUSTACEANS
    AIRRIESS, CN
    MCMAHON, BR
    MCGAW, IJ
    BOURNE, GB
    JOURNAL OF THE MARINE BIOLOGICAL ASSOCIATION OF THE UNITED KINGDOM, 1994, 74 (02) : 455 - 458
  • [24] MEASUREMENT OF FEMORAL-HEAD MICROCIRCULATION BY LASER DOPPLER FLOWMETRY
    BASSETT, GS
    APEL, DM
    WINTERSTEEN, VG
    TOLO, VT
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (03) : 307 - 313
  • [25] APPLICATION OF DOPPLER ULTRASOUND TO BLOOD-PRESSURE MEASUREMENT IN SMALL INFANTS
    BLACK, IFS
    MASSIE, H
    KOTRAPU, N
    JOURNAL OF PEDIATRICS, 1972, 81 (05): : 932 - +
  • [26] Laser Doppler method for investigation of blood microcirculation in mucous membrane
    Sedykh, AV
    Kharish, NA
    Lepilin, AV
    Ulyanov, SS
    SARTOV FALL MEETING '99: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE, 2000, 4001 : 190 - 195
  • [27] Integrated laser Doppler blood flowmeter combining optical contact force
    Nogami, Hirofumi
    Komatsutani, Kosuke
    Hirata, Tomoki
    Sawada, Renshi
    2019 INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING (ICEP 2019), 2019, : 287 - 290
  • [28] EARLY DETECTION OF LUNG REJECTION BY MEASUREMENT OF BRONCHIAL MUCOSAL BLOOD-FLOW USING LASER DOPPLER FLOWMETER
    TANABE, H
    YADA, I
    NAMIKAWA, S
    KUSAGAWA, M
    TRANSPLANTATION PROCEEDINGS, 1989, 21 (01) : 2590 - 2591
  • [29] Laser Doppler flowmeter measurement of relative gingival and forehead skin blood flow in light and regular smokers.
    Meekin, TN
    Wilson, RF
    Scott, DA
    Palmer, RM
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1067 - 1067
  • [30] PARTITIONAL MEASUREMENT OF CAPILLARY AND ARTERIOVENOUS ANASTOMOTIC BLOOD-FLOW IN THE HUMAN FINGER BY LASER-DOPPLER-FLOWMETER
    HIRATA, K
    NAGASAKA, T
    NODA, Y
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1988, 57 (05) : 616 - 621