Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [31] MEASUREMENT OF SKELETAL-MUSCLE BLOOD-FLOW IN BULLET WOUNDING WITH A NEW LASER-DOPPLER FLOWMETER
    OBERG, PA
    NILSSON, GE
    TENLAND, T
    HOLMSTROM, A
    LEWIS, DH
    MICROVASCULAR RESEARCH, 1979, 18 (02) : 298 - 298
  • [32] TRANSCUTANEOUS DOPPLER MEASUREMENT OF BLOOD PRESSURE
    KIRBY, RR
    KEMMERER, WT
    MORGAN, JL
    ANESTHESIOLOGY, 1969, 31 (01) : 86 - &
  • [33] STUDIES ON THE EFFECTS OF CO2-BATHS - MEASUREMENTS ON THE MICROCIRCULATION OF SKIN BY MEANS OF A LASER DOPPLER FLOWMETER
    ERDL, R
    SCHNIZER, W
    SCHOPS, P
    HERZ KREISLAUF, 1986, 18 (08): : 387 - 391
  • [34] LASER DOPPLER TECHNIQUE FOR THE MEASUREMENT OF DIGITAL AND SEGMENTAL SYSTOLIC BLOOD-PRESSURE
    BEINDER, E
    HOFFMANN, U
    FRANZECK, UK
    HUCH, A
    HUCH, R
    BOLLINGER, A
    VASA-JOURNAL OF VASCULAR DISEASES, 1992, 21 (01): : 15 - 21
  • [35] LASER SPECKLE MEASUREMENT OF BLOOD VELOCITY IN IRIS MICROCIRCULATION
    TAGAWA, H
    FURUKAWA, H
    FUJII, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 808 - 808
  • [36] Laser Doppler flux measurement for the assessment of cutaneous microcirculation - critical remarks
    Jung, F.
    Leithaeuser, B.
    Landgraf, H.
    Juenger, M.
    Franzeck, U.
    Pries, A.
    Sternitzky, R.
    Franke, R. P.
    Forconi, S.
    Ehrly, A. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2013, 55 (04) : 411 - 416
  • [37] LASER DOPPLER MICROSCOPE FOR HIGH ACCURATE VELOCITY-MEASUREMENT OF MICROCIRCULATION
    OKADA, E
    MINAMITANI, H
    FUKUOKA, Y
    OHSHIO, C
    SUEMATSU, M
    SUZUKI, M
    TSUCHIYA, M
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1321 - 1323
  • [38] EVALUATION OF THE MICROCIRCULATION IN A SHEEP ISLAND PEDICLE FLAP WITH LASER DOPPLER FLOWMETER AND TC-99M-LABELED RED-BLOOD-CELLS
    BANIC, A
    KOURIS, K
    LEWIS, DH
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1990, 6 (04) : 345 - 351
  • [39] Verification and Calibration of Laser Doppler Flowmetry (LDF) Prototype for Measurement of Microcirculation
    Li, Yung-Hui
    Hu, Chia-Ming
    Tsai, Ming-Lun
    AOPC 2017: LASER COMPONENTS, SYSTEMS, AND APPLICATIONS, 2017, 10457
  • [40] Endoscopic measurement of bronchial and pulmonary microcirculation with laser Doppler perfusion meter
    Taivans, I
    Lejnieks, J
    Strazda, G
    Jurka, N
    1ST MEDITERRANEAN CONGRESS ON INTERVENTIONAL DIAGNOSIS FOR THORAX DISEASES, 1996, : 665 - 668