Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [1] BLOOD PRESSURE MEASUREMENT WITH DOPPLER ULTRASONIC FLOWMETER
    KAZAMIAS, TM
    GANDER, MP
    FRANKLIN, DL
    ROSS, J
    JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (04) : 585 - &
  • [2] Portable laser Doppler flowmeter for microcirculation detection
    Hu C.-L.
    Lin Z.-S.
    Chen Y.-Y.
    Lin Y.-H.
    Li M.-L.
    Biomedical Engineering Letters, 2013, 3 (2) : 109 - 114
  • [3] LASER DOPPLER MEASUREMENT OF BLOOD-FLOW IN MICROCIRCULATION
    POWERS, EW
    FRAYER, WW
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 61 (02) : 250 - 255
  • [4] Assessing microcirculation in familial dysautonomia by laser Doppler flowmeter
    Michael Weiser
    Max J. Hilz
    Ludmila Bronfin
    Felicia B. Axelrod
    Clinical Autonomic Research, 1998, 8 : 13 - 23
  • [5] EVALUATION OF GINGIVAL MICROCIRCULATION BY A LASER-DOPPLER FLOWMETER
    BOUTAULT, F
    CADENAT, H
    HIBERT, PJ
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1989, 17 (03): : 105 - 109
  • [6] Quantitative measurement of gastric mucosal microcirculation using a combined laser Doppler flowmeter and spectrophotometer
    Bludau, M.
    Vallboehmer, D.
    Gutschow, C.
    Hoelscher, A. H.
    Schroeder, W.
    DISEASES OF THE ESOPHAGUS, 2008, 21 (07) : 668 - 672
  • [7] Assessing microcirculation in familial dysautonomia by laser Doppler flowmeter
    Weiser, M
    Hilz, MJ
    Bronfin, L
    Axelrod, FB
    CLINICAL AUTONOMIC RESEARCH, 1998, 8 (01) : 13 - 23
  • [8] EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW
    NILSSON, GE
    TENLAND, T
    OBERG, PA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) : 597 - 604
  • [9] STUDIES OF MICROCIRCULATION IN HUMAN NASAL-MUCOSA WITH A LASER DOPPLER FLOWMETER
    OLSSON, P
    BENDE, M
    BISGAARD, H
    OHLIN, P
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (01): : 71 - 72
  • [10] THE LASER DOPPLER FLOWMETER FOR MEASURING MICROCIRCULATION IN HUMAN NASAL-MUCOSA
    OLSSON, P
    BENDE, M
    OHLIN, P
    ACTA OTO-LARYNGOLOGICA, 1985, 99 (1-2) : 133 - 139