Fiber optic biosensor for transdermal glucose based on the glucose binding protein

被引:30
|
作者
Tiangco, Cristina [1 ,4 ]
Fon, Dieudonne [1 ,2 ]
Sardesai, Neha [1 ,3 ]
Kostov, Yordan [1 ,3 ]
Sevilla, Fortunato, III [4 ]
Rao, Govind [1 ,2 ]
Tolosa, Leah [1 ,2 ]
机构
[1] Univ Maryland Baltimore Cty, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
[2] Univ Maryland Baltimore Cty, Dept Chem Biochem & Environm Engn, Baltimore, MD 21250 USA
[3] Univ Maryland Baltimore Cty, Dept Comp Sci & Elect Engn, Baltimore, MD 21250 USA
[4] Univ Santo Tomas, Grad Sch, Espana Blvd, Manila 1015, Philippines
关键词
Biosensor; Optical fiber; Transdermal glucose; Glucose binding protein; CONTACT-LENS; TEAR GLUCOSE; SENSOR;
D O I
10.1016/j.snb.2016.11.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In previous work, a painless, noninvasive method of collecting transdermal glucose (TG) passively diffusing through the skin was developed. The transdermal glucose collected in this way has concentrations in the mu M range requiring a reliable sensor that can measure glucose at these levels. In this study, a fiber optic biosensor for mu M glucose based on the glucose binding protein (GBP) is described. The GBP was labeled with BADAN in the H152C position and immobilized on Ni-NTA agarose beads via metal-histidine interaction. The portable, low-cost biosensor system consists of an optical fiber with the sensitized beads trapped on one end, and appropriate optics and electronics on the other end. The control software and the visual interface for the optical sensor is designed and implemented in LabVIEW and runs on a tablet computer. Optimization of sensor response was performed by varying the amount of Ni-NTA-GBP sensitized beads and its distance to the optical fiber. The biosensor exhibited a stable response to buffer and in 10.0 mu M glucose even after similar to 16 h of continuous use. Glucose response is reversible when cycled between phosphate-buffered saline solution and various glucose solutions. The response time of the biosensor in 6 mu M glucose was approximately 50 s. A linear relationship (r(2) = 0.990) between sensor response and glucose concentrations from 4.00 to 20.00 mu M was obtained. Measurement of transdermal glucose diffusion was demonstrated with Yucatan minipig skin as surrogate for human skin. The results show the potential of this fiber optic biosensor as a transdermal glucose monitoring system at the point of care. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:569 / 576
页数:8
相关论文
共 50 条
  • [41] Fabrication of polyaniline-HCl cladding modified fiber optic intrinsic biosensor for glucose detection
    Pahurkar, Vikas
    Tamgadge, Yuoraj
    Muley, Gajanan
    INTERNATIONAL CONFERENCE ON CONDENSED MATTER AND APPLIED PHYSICS (ICC 2015), 2016, 1728
  • [42] Localized Surface Plasmon Resonance-Based Fiber Optic U-Shaped Biosensor for the Detection of Blood Glucose
    Srivastava, Sachin K.
    Arora, Vikas
    Sapra, Sameer
    Gupta, Banshi D.
    PLASMONICS, 2012, 7 (02) : 261 - 268
  • [43] Localized Surface Plasmon Resonance-Based Fiber Optic U-Shaped Biosensor for the Detection of Blood Glucose
    Sachin K. Srivastava
    Vikas Arora
    Sameer Sapra
    Banshi D. Gupta
    Plasmonics, 2012, 7 : 261 - 268
  • [44] A Novel Large-Diameter Optical Fiber Glucose Biosensor Based on Glucose Oxidase Graphene OxideGold Nanoparticles
    Xu, Bing
    Xiang, Xiaoying
    Ding, Liyun
    Luo, Zhihui
    Zhao, Jue
    Huang, Jun
    Li, Haijun
    Jiang, Xingdong
    IEEE SENSORS JOURNAL, 2023, 23 (07) : 6832 - 6839
  • [45] S-shaped long period fiber grating glucose concentration biosensor based on immobilized glucose oxidase
    Wu, Chao-Wei
    OPTIK, 2020, 203
  • [46] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14
  • [47] Fiber Optic Sensors: A Review for Glucose Measurement
    Cano Perez, Jose Luis
    Gutierrez-Gutierrez, Jaime
    Perezcampos Mayoral, Christian
    Perez-Campos, Eduardo L.
    Pina Canseco, Maria del Socorro
    Tepech Carrillo, Lorenzo
    Mayoral, Laura Perez-Campos
    Vargas Trevino, Marciano
    Apreza, Edmundo Lopez
    Rojas Laguna, Roberto
    BIOSENSORS-BASEL, 2021, 11 (03):
  • [48] DEVELOPMENT OF A FIBER OPTIC OXYGEN AND GLUCOSE SENSOR
    SHAH, R
    GOLD, M
    SCHAFFER, RM
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 742 - 744
  • [49] Nano-yarn carbon nanotube fiber based enzymatic glucose biosensor
    Zhu, Zhigang
    Song, Wenhui
    Burugapalli, Krishna
    Moussy, Francis
    Li, Ya-Li
    Zhong, Xiao-Hua
    NANOTECHNOLOGY, 2010, 21 (16)
  • [50] A novel flow through optical fiber biosensor for glucose based on luminol electrochemiluminescence
    Zhu, L
    Li, YX
    Zhu, GY
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3) : 209 - 214