Fiber optic biosensor for transdermal glucose based on the glucose binding protein

被引:30
|
作者
Tiangco, Cristina [1 ,4 ]
Fon, Dieudonne [1 ,2 ]
Sardesai, Neha [1 ,3 ]
Kostov, Yordan [1 ,3 ]
Sevilla, Fortunato, III [4 ]
Rao, Govind [1 ,2 ]
Tolosa, Leah [1 ,2 ]
机构
[1] Univ Maryland Baltimore Cty, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
[2] Univ Maryland Baltimore Cty, Dept Chem Biochem & Environm Engn, Baltimore, MD 21250 USA
[3] Univ Maryland Baltimore Cty, Dept Comp Sci & Elect Engn, Baltimore, MD 21250 USA
[4] Univ Santo Tomas, Grad Sch, Espana Blvd, Manila 1015, Philippines
关键词
Biosensor; Optical fiber; Transdermal glucose; Glucose binding protein; CONTACT-LENS; TEAR GLUCOSE; SENSOR;
D O I
10.1016/j.snb.2016.11.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In previous work, a painless, noninvasive method of collecting transdermal glucose (TG) passively diffusing through the skin was developed. The transdermal glucose collected in this way has concentrations in the mu M range requiring a reliable sensor that can measure glucose at these levels. In this study, a fiber optic biosensor for mu M glucose based on the glucose binding protein (GBP) is described. The GBP was labeled with BADAN in the H152C position and immobilized on Ni-NTA agarose beads via metal-histidine interaction. The portable, low-cost biosensor system consists of an optical fiber with the sensitized beads trapped on one end, and appropriate optics and electronics on the other end. The control software and the visual interface for the optical sensor is designed and implemented in LabVIEW and runs on a tablet computer. Optimization of sensor response was performed by varying the amount of Ni-NTA-GBP sensitized beads and its distance to the optical fiber. The biosensor exhibited a stable response to buffer and in 10.0 mu M glucose even after similar to 16 h of continuous use. Glucose response is reversible when cycled between phosphate-buffered saline solution and various glucose solutions. The response time of the biosensor in 6 mu M glucose was approximately 50 s. A linear relationship (r(2) = 0.990) between sensor response and glucose concentrations from 4.00 to 20.00 mu M was obtained. Measurement of transdermal glucose diffusion was demonstrated with Yucatan minipig skin as surrogate for human skin. The results show the potential of this fiber optic biosensor as a transdermal glucose monitoring system at the point of care. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:569 / 576
页数:8
相关论文
共 50 条
  • [21] Performance of Cladding Modified PANI-ZnO Nanocomposite Glucose Oxidase Immobilized Fiber Optic Intrinsic Glucose Biosensor
    Pahurkar, Vikas
    Harde, Gajanan
    Nagale, Vinod
    Muley, Gajanan
    MACROMOLECULAR SYMPOSIA, 2016, 362 (01) : 101 - 104
  • [22] Cladding Modified with PANI-Oxalic Acid Composite Glucose Oxidase Immobilized Fiber Optic Intrinsic Glucose Biosensor
    Pahurkar, Vikas
    Dagdale, Shivaji
    Tamgadge, Yuoraj
    Nagale, Vinod
    Muley, Gajanan
    MACROMOLECULAR SYMPOSIA, 2016, 362 (01) : 149 - 151
  • [23] A fluorescence lifetime-based fibre-optic glucose sensor using glucose/galactose-binding protein
    Saxl, Tania
    Khan, Faaizah
    Ferla, Matteo
    Birch, David
    Pickup, John
    ANALYST, 2011, 136 (05) : 968 - 972
  • [24] Fibre optic biosensor for the determination of D-glucose based on absorption changes of immobilized glucose oxidase
    Chudobova, I
    Vrbova, E
    Kodicek, M
    Janovcova, J
    Kas, J
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 103 - 110
  • [25] Macroscopic Carbon Nanotube Fiber Film Based Glucose Biosensor
    Feng, Yan
    Feng, Ningning
    Bai, Yu
    Wang, Xiang
    Zhou, Xiaopu
    Zhang, Yuliang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 10100 - 10111
  • [26] FULLY REVERSIBLE FIBRE-OPTIC GLUCOSE BIOSENSOR BASED ON THE INTRINSIC FLUORESCENCE OF GLUCOSE-OXIDASE
    TRETTNAK, W
    WOLFBEIS, OS
    ANALYTICA CHIMICA ACTA, 1989, 221 (02) : 195 - 203
  • [28] OPTICAL SENSORS .34. FIBER OPTIC GLUCOSE BIOSENSOR WITH AN OXYGEN OPTRODE AS THE TRANSDUCER
    TRETTNAK, W
    LEINER, MJP
    WOLFBEIS, OS
    ANALYST, 1988, 113 (10) : 1519 - 1523
  • [29] Engineering and rapid selection of a low-affinity glucose/galactose-binding protein for a glucose biosensor
    Amiss, Terry J.
    Sherman, Douglas B.
    Nycz, Colleen M.
    Andaluz, Sandra A.
    Pitner, J. Bruce
    PROTEIN SCIENCE, 2007, 16 (11) : 2350 - 2359
  • [30] The trehalose/maltose-binding protein as the sensitive element of a glucose biosensor
    Fonin, A. V.
    Povarova, O. I.
    Staiano, M.
    D'Auria, S.
    Turoverov, K. K.
    Kuznetsova, I. M.
    OPTICAL MATERIALS, 2014, 36 (10) : 1676 - 1679