Fiber optic biosensor for transdermal glucose based on the glucose binding protein

被引:30
|
作者
Tiangco, Cristina [1 ,4 ]
Fon, Dieudonne [1 ,2 ]
Sardesai, Neha [1 ,3 ]
Kostov, Yordan [1 ,3 ]
Sevilla, Fortunato, III [4 ]
Rao, Govind [1 ,2 ]
Tolosa, Leah [1 ,2 ]
机构
[1] Univ Maryland Baltimore Cty, Ctr Adv Sensor Technol, Baltimore, MD 21250 USA
[2] Univ Maryland Baltimore Cty, Dept Chem Biochem & Environm Engn, Baltimore, MD 21250 USA
[3] Univ Maryland Baltimore Cty, Dept Comp Sci & Elect Engn, Baltimore, MD 21250 USA
[4] Univ Santo Tomas, Grad Sch, Espana Blvd, Manila 1015, Philippines
关键词
Biosensor; Optical fiber; Transdermal glucose; Glucose binding protein; CONTACT-LENS; TEAR GLUCOSE; SENSOR;
D O I
10.1016/j.snb.2016.11.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In previous work, a painless, noninvasive method of collecting transdermal glucose (TG) passively diffusing through the skin was developed. The transdermal glucose collected in this way has concentrations in the mu M range requiring a reliable sensor that can measure glucose at these levels. In this study, a fiber optic biosensor for mu M glucose based on the glucose binding protein (GBP) is described. The GBP was labeled with BADAN in the H152C position and immobilized on Ni-NTA agarose beads via metal-histidine interaction. The portable, low-cost biosensor system consists of an optical fiber with the sensitized beads trapped on one end, and appropriate optics and electronics on the other end. The control software and the visual interface for the optical sensor is designed and implemented in LabVIEW and runs on a tablet computer. Optimization of sensor response was performed by varying the amount of Ni-NTA-GBP sensitized beads and its distance to the optical fiber. The biosensor exhibited a stable response to buffer and in 10.0 mu M glucose even after similar to 16 h of continuous use. Glucose response is reversible when cycled between phosphate-buffered saline solution and various glucose solutions. The response time of the biosensor in 6 mu M glucose was approximately 50 s. A linear relationship (r(2) = 0.990) between sensor response and glucose concentrations from 4.00 to 20.00 mu M was obtained. Measurement of transdermal glucose diffusion was demonstrated with Yucatan minipig skin as surrogate for human skin. The results show the potential of this fiber optic biosensor as a transdermal glucose monitoring system at the point of care. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:569 / 576
页数:8
相关论文
共 50 条
  • [31] The construction of glucose biosensor based on crystalline iridium(III)-containing coordination polymers with fiber-optic detection
    Ho, Mei-Lin
    Wang, Jing-Chang
    Wang, Ting-Yi
    Lin, Chun-Yen
    Zhu, Jian Fan
    Chen, Yi-An
    Chen, Tsai-Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 479 - 485
  • [32] Evanescent wave absorption based polyaniline cladding modified fiber optic intrinsic biosensor for glucose sensing application
    Pahurkar, V. G.
    Tamgadge, Y. S.
    Gambhire, A. B.
    Muley, G. G.
    MEASUREMENT, 2015, 61 : 9 - 15
  • [33] Multi-day pre-clinical demonstration of glucose/galactose binding protein-based fiber optic sensor
    Weidemaier, Kristin
    Lastovich, Alexander
    Keith, Steven
    Pitner, J. Bruce
    Sistare, Mark
    Jacobson, Ross
    Kurisko, David
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (10): : 4117 - 4123
  • [34] Reusability study of fiber optic based protein C biosensor
    Spiker, JO
    Drohan, WN
    Kang, KA
    OXYGEN TRANSPORT TO TISSUE XXI, 1999, 471 : 731 - 739
  • [35] Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
    Brown, Sheniqua
    Zambrana, Paige N.
    Ge, Xudong
    Bagdure, Dayanand
    Stinchcomb, Audra L.
    Rao, Govind
    Tolosa, Leah
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (27) : 7249 - 7260
  • [36] Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
    Sheniqua Brown
    Paige N. Zambrana
    Xudong Ge
    Dayanand Bagdure
    Audra L. Stinchcomb
    Govind Rao
    Leah Tolosa
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7249 - 7260
  • [37] Glucose determination with fiber optic spectrometers
    Starke, E
    Kemper, U
    Barschdorff, D
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 25 - 32
  • [38] ENZYME-BASED FIBER OPTIC SENSOR FOR GLUCOSE DETERMINATION
    ABDELLATIF, MS
    SULEIMAN, AA
    GUILBAULT, GG
    ANALYTICAL LETTERS, 1988, 21 (06) : 943 - 951
  • [39] Glucose biosensor based on the microcantilever
    Pei, JH
    Tian, F
    Thundat, T
    ANALYTICAL CHEMISTRY, 2004, 76 (02) : 292 - 297
  • [40] Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics
    Chou, Chien
    Hsu, Hsien-Yeh
    Wu, Hsieh-Ting
    Tseng, Kai-Yu
    Chiou, Arthur
    Yu, Chih-Jen
    Lee, Zheng-Yuan
    Chan, Tsu-Shin
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)