Non-contact Laser-based Human Respiration Rate Measurement

被引:7
|
作者
Scalise, L. [1 ]
Marchionni, P. [1 ]
Ercoli, I. [1 ]
机构
[1] Polytech Univ Marche, Dept Mech, I-60131 Ancona, Italy
关键词
Non-contact monitoring; Respiration rate; Laser Doppler Vibrometry;
D O I
10.1063/1.3626924
中图分类号
O59 [应用物理学];
学科分类号
摘要
At present the majority of the instrumentation, used in clinical environments, to measure human respiration rate are based on invasive and contact devices. The gold standard instrument is considered the spirometer which is largely used; it needs a direct contact and requires a collaboration by the patient. Laser Doppler Vibrometer (LDVi) is an optical, non-contact measurement system for the assessment of a surface velocity and displacement. LDVi has already been used for the measurement of the cardiac activity and for the measurement of the chest-wall displacements. The aims of this work are to select the best measurement point on the thoracic surface for LDVi monitoring of the respiration rate (RR) and to compare measured data with the RR valued provided by the spirometer. The measurement system is composed by a LDV system and a data acquisition board installed on a PC. Tests were made on 10 different point of the thorax for each patient. Patients population was composed by 33 subjects (17 male and 16 female). The optimal measurement point was chosen considering the maximum peak-to-peak value of the displacement measured by LDV. Before extracting RR we have used a special wavelet decomposition for better selection of the expiration peaks. A standard spirometer was used for the validation of the data. From tests it results that the optimal measurement point, namely is located on the inferior part of the thoracic region (left, front side). From our tests we have obtained a close correlation between the RR values measured by the spirometer and those measured by the proposed method: a difference of 14 +/- 211 ms on the RR value is reported for the entire population of 33 subjects. Our method allows a no-contact measurement of lungs activity (respiration period), reducing the electric and biological risks. Moreover it allows to measure in critical environment like in RMN or in burned skin where is difficult or impossible to apply electrodes.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [41] Non-contact Measurement Method of Bridge Vibration Based on Laser Strip Tracking
    Tang L.
    Wu T.
    Du P.
    Liu N.
    Zhou Z.
    Qi X.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2022, 54 (06): : 135 - 145
  • [42] Non-contact angle measurement based on parallel multiplex laser feedback interferometry
    Zhang Song
    Tan Yi-Dong
    Zhang Shu-Lian
    CHINESE PHYSICS B, 2014, 23 (11)
  • [43] Non-contact Measurement of Human Heart Rate Using Low Cost Video Camera
    Sharma, Naveen
    Kaman, Surjit
    Mahapatra, Prasant K.
    2019 FIFTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP 2019), 2019, : 58 - 62
  • [44] Non-Contact Measurement of Human Respiration and Heartbeat Using W-band Doppler Radar Sensor
    Kim, Heesoo
    Jeong, Jinho
    SENSORS, 2020, 20 (18)
  • [45] Non-contact detection of human heart rate with Kinect
    Liqian Zhou
    Ming Yin
    Xi Xu
    Xinpan Yuan
    Xiaojun Liu
    Cluster Computing, 2019, 22 : 8199 - 8206
  • [46] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [47] Non-contact detection of human heart rate with Kinect
    Zhou, Liqian
    Yin, Ming
    Xu, Xi
    Yuan, Xinpan
    Liu, Xiaojun
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (Suppl 4): : S8199 - S8206
  • [48] Non-Contact Respiratory Rate Measurement Validation for Hospitalized Patients
    Droitcour, Amy D.
    Seto, Todd B.
    Park, Byung-Kwon
    Yamada, Shuhei
    Vergara, Alex
    El Hourani, Charles
    Shing, Tommy
    Yuen, Andrea
    Lubecke, Victor M.
    Boric-Lubecke, Olga
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4812 - +
  • [49] Development of Non-Contact Measurement System of Human Stepping
    Kurita, Koichi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 1031 - 1034
  • [50] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241