Non-contact Laser-based Human Respiration Rate Measurement

被引:7
|
作者
Scalise, L. [1 ]
Marchionni, P. [1 ]
Ercoli, I. [1 ]
机构
[1] Polytech Univ Marche, Dept Mech, I-60131 Ancona, Italy
关键词
Non-contact monitoring; Respiration rate; Laser Doppler Vibrometry;
D O I
10.1063/1.3626924
中图分类号
O59 [应用物理学];
学科分类号
摘要
At present the majority of the instrumentation, used in clinical environments, to measure human respiration rate are based on invasive and contact devices. The gold standard instrument is considered the spirometer which is largely used; it needs a direct contact and requires a collaboration by the patient. Laser Doppler Vibrometer (LDVi) is an optical, non-contact measurement system for the assessment of a surface velocity and displacement. LDVi has already been used for the measurement of the cardiac activity and for the measurement of the chest-wall displacements. The aims of this work are to select the best measurement point on the thoracic surface for LDVi monitoring of the respiration rate (RR) and to compare measured data with the RR valued provided by the spirometer. The measurement system is composed by a LDV system and a data acquisition board installed on a PC. Tests were made on 10 different point of the thorax for each patient. Patients population was composed by 33 subjects (17 male and 16 female). The optimal measurement point was chosen considering the maximum peak-to-peak value of the displacement measured by LDV. Before extracting RR we have used a special wavelet decomposition for better selection of the expiration peaks. A standard spirometer was used for the validation of the data. From tests it results that the optimal measurement point, namely is located on the inferior part of the thoracic region (left, front side). From our tests we have obtained a close correlation between the RR values measured by the spirometer and those measured by the proposed method: a difference of 14 +/- 211 ms on the RR value is reported for the entire population of 33 subjects. Our method allows a no-contact measurement of lungs activity (respiration period), reducing the electric and biological risks. Moreover it allows to measure in critical environment like in RMN or in burned skin where is difficult or impossible to apply electrodes.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [31] Non-contact Methods for Heart Rate Measurement: A Review
    Kaur, Gaganjot
    Kilby, Jeff
    2021 INTERNATIONAL CONFERENCE ON COMPUTING SCIENCES (ICCS 2021), 2021, : 289 - 294
  • [32] Full non-contact laser-based Lamb waves phased array inspection of aluminum plate
    Zenghua Liu
    Honglei Chen
    Kunming Sun
    Cunfu He
    Bin Wu
    Journal of Visualization, 2018, 21 : 751 - 761
  • [33] Full non-contact laser-based Lamb waves phased array inspection of aluminum plate
    Liu, Zenghua
    Chen, Honglei
    Sun, Kunming
    He, Cunfu
    Wu, Bin
    JOURNAL OF VISUALIZATION, 2018, 21 (05) : 751 - 761
  • [34] New laser vibrometer for non-contact vibration measurement
    不详
    ZKG INTERNATIONAL, 2014, 67 (1-2): : 20 - 20
  • [35] Non-contact Respiration Measurement by Using RGB-D Camera
    Aoki, Hirooki
    Fujita, Noriaki
    2022 JOINT 12TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS AND 23RD INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (SCIS&ISIS), 2022,
  • [36] The Design and Implementation of a Non-contact Laser Measurement System
    ZHANG Ni ZHANG Yunwen LIU Weijun PU Xiongying China Agricultural University BeijingShenyang Institute of Automation Chinese Academy of SciencesShenyangChina
    微计算机信息, 2008, (22) : 7 - 9+162
  • [37] Research on non-contact respiratory rate measurement method based on video information
    Li S.
    Wang H.
    Liu Y.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (06): : 1173 - 1180
  • [38] Non-contact angle measurement based on parallel multiplex laser feedback interferometry
    张松
    谈宜东
    张书练
    Chinese Physics B, 2014, (11) : 324 - 328
  • [39] A non-contact method for rod straightness measurement based on quadrant laser sensor
    Rana, N. K.
    Sawant, R. R.
    Moon, A. H.
    2006 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-6, 2006, : 2645 - +
  • [40] Non-contact Surface Roughness Measurement Based on Laser Technology and Neural Network
    Xu, Xiaomei
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 4474 - 4478