Non-contact Laser-based Human Respiration Rate Measurement

被引:7
|
作者
Scalise, L. [1 ]
Marchionni, P. [1 ]
Ercoli, I. [1 ]
机构
[1] Polytech Univ Marche, Dept Mech, I-60131 Ancona, Italy
关键词
Non-contact monitoring; Respiration rate; Laser Doppler Vibrometry;
D O I
10.1063/1.3626924
中图分类号
O59 [应用物理学];
学科分类号
摘要
At present the majority of the instrumentation, used in clinical environments, to measure human respiration rate are based on invasive and contact devices. The gold standard instrument is considered the spirometer which is largely used; it needs a direct contact and requires a collaboration by the patient. Laser Doppler Vibrometer (LDVi) is an optical, non-contact measurement system for the assessment of a surface velocity and displacement. LDVi has already been used for the measurement of the cardiac activity and for the measurement of the chest-wall displacements. The aims of this work are to select the best measurement point on the thoracic surface for LDVi monitoring of the respiration rate (RR) and to compare measured data with the RR valued provided by the spirometer. The measurement system is composed by a LDV system and a data acquisition board installed on a PC. Tests were made on 10 different point of the thorax for each patient. Patients population was composed by 33 subjects (17 male and 16 female). The optimal measurement point was chosen considering the maximum peak-to-peak value of the displacement measured by LDV. Before extracting RR we have used a special wavelet decomposition for better selection of the expiration peaks. A standard spirometer was used for the validation of the data. From tests it results that the optimal measurement point, namely is located on the inferior part of the thoracic region (left, front side). From our tests we have obtained a close correlation between the RR values measured by the spirometer and those measured by the proposed method: a difference of 14 +/- 211 ms on the RR value is reported for the entire population of 33 subjects. Our method allows a no-contact measurement of lungs activity (respiration period), reducing the electric and biological risks. Moreover it allows to measure in critical environment like in RMN or in burned skin where is difficult or impossible to apply electrodes.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [21] A non-contact laser probe in industrial measurement
    Li, Y
    Zhang, LX
    Zhang, SL
    Han, YM
    1999 INTERNATIONAL CONFERENCE ON INDUSTRIAL LASERS (IL'99), 1999, 3862 : 306 - 310
  • [22] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [23] A non-contact laser-based alignment system (LBAS) for nuclear-physics experiments
    Rogers, A. M.
    Lee, J.
    Nett, B. E.
    Wallace, M. S.
    Lynch, W. G.
    Cheung, H. K.
    El-Mogaber, L.
    Fontus, R.
    Ghosh, T. K.
    Henzl, V.
    Henzlova, D.
    Kilburn, M.
    Oostdyk, D. J.
    Sanderson, D.
    Sun, Z. Y.
    Tsang, M. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 707 : 64 - 68
  • [24] Non-mydriatic panoramic fundus imaging using a non-contact scanning laser-based system
    Friberg, TR
    Pandya, A
    Eller, AW
    OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (06): : 488 - 497
  • [25] Non-contact optical measurement of material surfaces with a laser based sensor
    Satapathy, Priyanka
    Nath, Ganeswar
    Mishra, Punyatoya
    LASER PHYSICS, 2021, 31 (03)
  • [26] Non-contact measurement of the heart rate and the heart rate variability
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Drnovsek, Janko
    ELEKTROTEHNISKI VESTNIK, 2013, 80 (03): : 135 - 140
  • [27] Non-contact measurement of human respiration using an infrared thermal camera and the deep learning method
    Shu, Shuangbao
    Liang, Huajun
    Zhang, Yu
    Zhang, Yuzhong
    Yang, Ziqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (07)
  • [28] Blister-based-laser-induced-forward-transfer: a non-contact, dry laser-based transfer method for nanomaterials
    Goodfriend, N. T.
    Heng, S. Y.
    Nerushev, O. A.
    Gromov, A., V
    Bulgakov, A., V
    Okada, M.
    Xu, W.
    Kitaura, R.
    Warner, J.
    Shinohara, H.
    Campbell, E. E. B.
    NANOTECHNOLOGY, 2018, 29 (38)
  • [29] Non-contact Measurement of the Heart Rate by a Image Sensor
    Bernacchia, Natascia
    Marchionni, Paolo
    Ercoli, Ilaria
    Scalise, Lorenzo
    SENSORS, 2015, 319 : 371 - 375
  • [30] DEVELOPMENT OF A LASER-BASED OPTICAL ELECTRODE FOR REAL TIME NON-CONTACT MONITORING OF NERVE ACTIVITY
    Islam, M. Shahidul
    Haque, M. Rezuanul
    Oh, Christian
    Wang, Yan
    Park, B. Hyle