Non-contact Laser-based Human Respiration Rate Measurement

被引:7
|
作者
Scalise, L. [1 ]
Marchionni, P. [1 ]
Ercoli, I. [1 ]
机构
[1] Polytech Univ Marche, Dept Mech, I-60131 Ancona, Italy
关键词
Non-contact monitoring; Respiration rate; Laser Doppler Vibrometry;
D O I
10.1063/1.3626924
中图分类号
O59 [应用物理学];
学科分类号
摘要
At present the majority of the instrumentation, used in clinical environments, to measure human respiration rate are based on invasive and contact devices. The gold standard instrument is considered the spirometer which is largely used; it needs a direct contact and requires a collaboration by the patient. Laser Doppler Vibrometer (LDVi) is an optical, non-contact measurement system for the assessment of a surface velocity and displacement. LDVi has already been used for the measurement of the cardiac activity and for the measurement of the chest-wall displacements. The aims of this work are to select the best measurement point on the thoracic surface for LDVi monitoring of the respiration rate (RR) and to compare measured data with the RR valued provided by the spirometer. The measurement system is composed by a LDV system and a data acquisition board installed on a PC. Tests were made on 10 different point of the thorax for each patient. Patients population was composed by 33 subjects (17 male and 16 female). The optimal measurement point was chosen considering the maximum peak-to-peak value of the displacement measured by LDV. Before extracting RR we have used a special wavelet decomposition for better selection of the expiration peaks. A standard spirometer was used for the validation of the data. From tests it results that the optimal measurement point, namely is located on the inferior part of the thoracic region (left, front side). From our tests we have obtained a close correlation between the RR values measured by the spirometer and those measured by the proposed method: a difference of 14 +/- 211 ms on the RR value is reported for the entire population of 33 subjects. Our method allows a no-contact measurement of lungs activity (respiration period), reducing the electric and biological risks. Moreover it allows to measure in critical environment like in RMN or in burned skin where is difficult or impossible to apply electrodes.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] A NEW PRECISION NON-CONTACT LASER-BASED HYBRID MEASUREMENT METHODOLOGY
    Shetty, Devdas
    Ghosh, Suhash
    Campana, Claudio
    Atalay, Mustafa
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 7, PTS A AND B, 2012, : 1085 - 1094
  • [2] Non-contact, laser-based monitoring of physiological activity
    Scalise, L.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 85 (03) : 312 - 312
  • [3] Non-contact respiration rate measurement using a single thermal camera
    Hwang, Hyeonsang
    Lee, Eui Chul
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 8 - 8
  • [4] Toward a laser-based, non-contact acoustic landmine imager
    DiMarzio, CA
    Li, W
    Berg, LJ
    Sabatier, J
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS V, PTS 1 AND 2, 2000, 4038 : 740 - 747
  • [5] Non-contact, laser-based confocal microscope for corneal imaging
    Pascolini, Michele
    Carraro, Federico
    Codogno, Nicola
    Minozzi, Mattia
    Pajaro, Ronnye
    Tiso, Christian
    Menin, Giulia
    Pajaro, Simone
    Tanassi, Cesare
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)
  • [6] Non-Contact Heart Rate Measurement Based on Adaptive Notch Filter and Elimination of Respiration Harmonics
    Tazen, Moushumi
    Sasaoka, Naoto
    Okamoto, Yoshiharu
    IEEE ACCESS, 2023, 11 : 46107 - 46119
  • [7] Medical Radar Signal Dataset for Non-Contact Respiration and Heart Rate Measurement
    Edanami, Keisuke
    Sun, Guanghao
    DATA IN BRIEF, 2022, 40
  • [8] A non-contact laser-based sensor for surface analysis of a rotating shaft
    Deo, Ib Singh
    Nath, G.
    LASER PHYSICS, 2019, 29 (11)
  • [9] Non-contact laser-based method for measuring underground pipeline diameter
    Bao, Xiaohua
    Wang, Mingliang
    Zhou, Hu
    Guo, Shuai
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2024, 45 (10): : 200 - 208
  • [10] Non-contact vibration analysis using innovative laser-based methodology
    Noriega, Santiago
    Shetty, Devdas
    Eppes, Tom A.
    Kondo, Jun
    OPTOMECHATRONIC SENSORS, INSTRUMENTATION, AND COMPUTER-VISION SYSTEMS, 2006, 6375