Fast and accurate measurement of spectral emissivity with a portable field infrared spectrometer: ancillary equipment and methods

被引:7
|
作者
Zhang, YuZe [1 ,2 ]
Ni, Li [3 ]
Wu, Hua [4 ,5 ]
Jiang, XiaoGuang [5 ,6 ]
Han, Ying [7 ]
机构
[1] China Transport Telecommun & Informat Ctr, Dept Space Informat, Beijing, Peoples R China
[2] Natl Engn Lab Transportat Safety & Emergency Info, Beijing, Peoples R China
[3] Chinese Acad Sci, Key Lab Digital Earth Sci, Inst Remote Sensing & Digital Earth, Beijing, Peoples R China
[4] Chinese Acad Sci, State Key Lab Resources & Environm Informat Syst, Inst Geog Sci & Nat Resources Res, Beijing, Peoples R China
[5] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing, Peoples R China
[6] Chinese Acad Sci, Key Lab Quantitat Remote Sensing Informat Technol, Acad Optoelect, Beijing, Peoples R China
[7] Twenty First Century Aerosp Technol Co Ltd, Prod Dept, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
LAND-SURFACE-TEMPERATURE; RETRIEVAL;
D O I
10.1080/01431161.2018.1505062
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Validation of land surface emissivity (LSE) is very important for assessing the accuracy of remote sensing products and understanding the potential and limitations of retrieval methods. Currently, a commonly used method for obtaining in situ spectral emissivity at ground level is to use a portable Fourier Transform Infrared (FTIR) spectrometer, such as the Model 102F Portable Field Spectrometer. However, since complicated procedures are necessary to ensure the accuracy of measured spectral emissivity, the traditional measuring methods for the 102F FTIR, are usually time-consuming. Additionally, a time-consuming process also means the thermal environment can change, which can further decrease the accuracy of the measurement. A prior knowledge of the sample emissivity in certain wavelength intervals is also necessary for the calculations in the current software package for the 102F FTIR, which makes the performance of the estimated LSEs highly dependent on the accuracy of this prior knowledge. To overcome the limitations in measuring LSE with the 102F FTIR, this paper presents a new solution using well-designed ancillary equipment and an optimized temperature and emissivity separation algorithm. The ancillary equipment consists of 4 major parts and is mainly designed for rapidly switching the sample and the diffuse gold-plate using a remote control. As no extra manual adjustments are necessary in our method, it will obviously decrease the risk of thermal infrared environmental change during measurements. In addition, by using our ancillary equipment, the reflected environmental radiance over the height surface is now measurable instead of using the approximations at the ground. By using a Wavelet-Transformed Temperature and Emissivity Separation (WTTES) algorithm, the surface temperature and the spectral emissivity are now simultaneously obtained without any prior knowledge, thus making the retrievals more reasonable. According to the experiments, our method is more efficient and accurate for measuring the spectral emissivity through the 102F FTIR spectrometer.
引用
收藏
页码:1736 / 1749
页数:14
相关论文
共 50 条
  • [31] LAPTOP CHEMISTRY - A FIBEROPTIC, FIELD-PORTABLE, NEAR-INFRARED SPECTROMETER
    LYSAGHT, MJ
    VANZEE, JA
    CALLIS, JB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (02): : 507 - 515
  • [32] Portable infrared spectral radiance measurement apparatus based on PbSe detectors
    张磊
    戴景民
    尹哲
    Chinese Optics Letters, 2015, 13 (06) : 87 - 90
  • [33] Portable infrared spectral radiance measurement apparatus based on PbSe detectors
    Zhang, Lei
    Dai, Jingmin
    Yin, Zhe
    CHINESE OPTICS LETTERS, 2015, 13 (06)
  • [34] FAST AND ACCURATE MODEL REDUCTION FOR SPECTRAL METHODS IN UNCERTAINTY QUANTIFICATION
    Freitas, Francisco Damasceno
    Pulch, Roland
    Rommes, Joost
    INTERNATIONAL JOURNAL FOR UNCERTAINTY QUANTIFICATION, 2016, 6 (03) : 271 - 286
  • [35] Portable equipment for field measurement of the hand's absorption of vibration energy
    Burstrom, L
    Lundstrom, R
    SAFETY SCIENCE, 1998, 28 (01) : 15 - 20
  • [36] A fast incremental approach for accurate measurement of the displacement field
    Beghdadi, A
    Mesbah, M
    Monteil, J
    IMAGE AND VISION COMPUTING, 2003, 21 (04) : 383 - 399
  • [37] A fast portable emanometer for field measurement of radon and thoron flux
    Zahorowski, W
    Whittlestone, S
    RADIATION PROTECTION DOSIMETRY, 1996, 67 (02) : 109 - 120
  • [38] Correction Method for Infrared Spectral Emissivity Measurement System Based on Integrating Sphere Reflectometer
    Zhang Yu-feng
    Dai Jing-min
    Zhang Yu
    Pan Wei-dong
    Zhang Lei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (08) : 2267 - 2271
  • [39] Measurement and calculation of infrared emissivity of target with non-full field of view
    Zhang, Tong
    Dai, Xiaodong
    Chen, Chunsheng
    Chen, Liang
    Dai, Mengyan
    Liu, Haifeng
    Ren, Lina
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (01): : 1 - 5
  • [40] Fast discrimination of hydroxypropyl methyl cellulose using portable Raman spectrometer and multivariate methods
    Song, Biao
    Lu, Dan
    Peng, Ming
    Li, Xia
    Zou, Ye
    Huang, Meizhen
    Lu, Feng
    LASER PHYSICS, 2017, 27 (02)