Fast and accurate measurement of spectral emissivity with a portable field infrared spectrometer: ancillary equipment and methods

被引:7
|
作者
Zhang, YuZe [1 ,2 ]
Ni, Li [3 ]
Wu, Hua [4 ,5 ]
Jiang, XiaoGuang [5 ,6 ]
Han, Ying [7 ]
机构
[1] China Transport Telecommun & Informat Ctr, Dept Space Informat, Beijing, Peoples R China
[2] Natl Engn Lab Transportat Safety & Emergency Info, Beijing, Peoples R China
[3] Chinese Acad Sci, Key Lab Digital Earth Sci, Inst Remote Sensing & Digital Earth, Beijing, Peoples R China
[4] Chinese Acad Sci, State Key Lab Resources & Environm Informat Syst, Inst Geog Sci & Nat Resources Res, Beijing, Peoples R China
[5] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing, Peoples R China
[6] Chinese Acad Sci, Key Lab Quantitat Remote Sensing Informat Technol, Acad Optoelect, Beijing, Peoples R China
[7] Twenty First Century Aerosp Technol Co Ltd, Prod Dept, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
LAND-SURFACE-TEMPERATURE; RETRIEVAL;
D O I
10.1080/01431161.2018.1505062
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Validation of land surface emissivity (LSE) is very important for assessing the accuracy of remote sensing products and understanding the potential and limitations of retrieval methods. Currently, a commonly used method for obtaining in situ spectral emissivity at ground level is to use a portable Fourier Transform Infrared (FTIR) spectrometer, such as the Model 102F Portable Field Spectrometer. However, since complicated procedures are necessary to ensure the accuracy of measured spectral emissivity, the traditional measuring methods for the 102F FTIR, are usually time-consuming. Additionally, a time-consuming process also means the thermal environment can change, which can further decrease the accuracy of the measurement. A prior knowledge of the sample emissivity in certain wavelength intervals is also necessary for the calculations in the current software package for the 102F FTIR, which makes the performance of the estimated LSEs highly dependent on the accuracy of this prior knowledge. To overcome the limitations in measuring LSE with the 102F FTIR, this paper presents a new solution using well-designed ancillary equipment and an optimized temperature and emissivity separation algorithm. The ancillary equipment consists of 4 major parts and is mainly designed for rapidly switching the sample and the diffuse gold-plate using a remote control. As no extra manual adjustments are necessary in our method, it will obviously decrease the risk of thermal infrared environmental change during measurements. In addition, by using our ancillary equipment, the reflected environmental radiance over the height surface is now measurable instead of using the approximations at the ground. By using a Wavelet-Transformed Temperature and Emissivity Separation (WTTES) algorithm, the surface temperature and the spectral emissivity are now simultaneously obtained without any prior knowledge, thus making the retrievals more reasonable. According to the experiments, our method is more efficient and accurate for measuring the spectral emissivity through the 102F FTIR spectrometer.
引用
收藏
页码:1736 / 1749
页数:14
相关论文
共 50 条
  • [41] Fast detection of the tenderness of mulberry leaves by a portable near-infrared spectrometer with variable selection
    Zhao, Ziniu
    Liu, Yihan
    Yang, Shuo
    Li, Yurong
    Zhang, Yeshun
    Yan, Hui
    INFRARED PHYSICS & TECHNOLOGY, 2023, 133
  • [42] Concerning equipment and methods for accurate measurement of magnetic characteristics of metals and alloys
    Gray, JG
    Ross, AD
    ANNALEN DER PHYSIK, 1910, 33 (16) : 1413 - 1426
  • [43] A Fast Method to Measure TAN and TBN of Used Lubricant Oil Based on Portable Infrared Spectrometer
    Yang Kun
    Wu Tong
    Zou Mao
    Shi Li-jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (02) : 452 - 455
  • [44] Accurate and Portable Plastic Sorting using Diffuse Reflection and Transmission MEMS Spectrometer in the Mid-infrared
    Elsaeidy, Mohamed
    Anwar, Momen
    Samir, Islam
    Al Haron, Mohamed H.
    Mortada, Bassem
    Labib, Shady R.
    AboZyd, Samir
    Erfan, Mazen
    Sabry, Yasser
    Saadany, Bassam
    MOEMS AND MINIATURIZED SYSTEMS XXIII, 2024, 12899
  • [45] Measurement Methods for Fast and Accurate Blackhole Identification with Binary Tomography
    Cunha, Italo
    Teixeira, Renata
    Feamster, Nick
    Diot, Christophe
    IMC'09: PROCEEDINGS OF THE 2009 ACM SIGCOMM INTERNET MEASUREMENT CONFERENCE, 2009, : 254 - 266
  • [46] GONIOMETRIC SPECTROMETER FOR THE MEASUREMENT OF DIFFUSE REFLECTANCE AND TRANSMITTANCE OF SKIN IN THE INFRARED SPECTRAL REGION
    CLARK, C
    VINEGAR, R
    HARDY, JD
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (11) : 993 - 998
  • [47] Measurement of the Water Content and the Moisture Vaporization Enthalpy in Rice Cracker with Portable Near Infrared Spectrometer
    Takeyama, Maiko
    Takahashi, Tomoya
    Kikuchi, Ryoei
    Kumagai, Masanori
    Amano, Toshio
    Fujiwara, Kazuhiko
    Ogawa, Nobuaki
    BUNSEKI KAGAKU, 2011, 60 (01) : 33 - 38
  • [48] Accurate and fast identification of transgenic soybean plants by boosting methods with a handheld miniature spectrometer
    Zhang, Yancong
    Miao, Long
    Rao, Yuan
    Wang, Xiaobo
    Li, Jiajia
    Zhang, Xiaodan
    Deng, Youhui
    Tu, Lijing
    Jin, Xiu
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 137
  • [49] Exploring the added value of portable devices such as near infrared spectrometer in the field of illicit drugs analyses
    Wermelinger, Marc
    Coppey, Florentin
    Gaste, Laetitia
    Esseiva, Pierre
    FORENSIC SCIENCE INTERNATIONAL, 2023, 348
  • [50] Spectral emissivity and transmissivity measurement for zinc sulphide infrared window based on integrating-sphere reflectometry
    Zhang, Yu-Feng
    Dai, Jing-Min
    Zhang, Lei
    Pan, Wei-Dong
    OPTICAL ENGINEERING, 2013, 52 (08)