Measurement and calculation of infrared emissivity of target with non-full field of view

被引:0
|
作者
Zhang, Tong [1 ]
Dai, Xiaodong [1 ]
Chen, Chunsheng [1 ]
Chen, Liang [1 ]
Dai, Mengyan [1 ]
Liu, Haifeng [1 ]
Ren, Lina [1 ]
机构
[1] State Key Laboratory of NBC Protection for Civilian, Beijing,102205, China
关键词
Yarn - Aluminum alloys - Aluminum coatings - Electromagnetic wave emission - Infrared radiation;
D O I
暂无
中图分类号
学科分类号
摘要
Background disturbance is the main factor affecting the testing results of infrared radiation characteristics with non-full field of view (FOV). In this paper, according to Planck's radiation law, the methods of measuring and calculating radiation characteristics of targets with non-full FOV were established with formula derivation and disturbance offset. On this basis, the infrared emissivities of aluminum plate and carbon nanotubes(MWCNTs)composite coatings were tested comparatively by using a SR-5000N spectroradiometer with both full FOV and non-full FOV. The results show that with non-full FOV, the infrared emissivities obtained by this method are in accord with the results measured with full FOV and can reflect the true spectral characteristics of the samples. This progress can effectively solve the FOV limitations to the radiation characteristics test of the target and greatly expand its application field. ©, 2015, Chinese Society of Astronautics. All right reserved.
引用
收藏
页码:1 / 5
相关论文
共 50 条
  • [1] Infrared emissivity measurement methods considering target reflective characteristics
    Liu, Yin
    Li, Yiwen
    Ma, Simin
    Zhang, Puyousen
    Li, Yao
    Fan, Xiumei
    Li, Weiqin
    APPLIED OPTICS, 2024, 63 (31) : 8180 - 8188
  • [2] A field measurement method of spectral emissivity and research on the feature of soil thermal infrared emissivity
    Xiao, Q
    Liu, QH
    Li, XW
    Chen, LF
    Liu, Q
    Xin, XZ
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2003, 22 (05) : 373 - 378
  • [3] Calculation of background radiation and temperature field of infrared target
    Wei, XZ
    Li, X
    Zhang, ZW
    Fu, YW
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 19 (02) : 139 - 141
  • [5] Volume flow rate calculation model of non-full pipe multiphase flow based on ultrasonic sensors
    Liang, Haibo
    Song, Chuanhao
    Li, Zhongbin
    Yang, Hai
    PHYSICS OF FLUIDS, 2023, 35 (03)
  • [6] Field of view measurement and correction term calculation for small-field radiometer
    Yang, Zhen-Ling
    Fang, Wei
    Wang, Kai
    Jiang, Ming
    Song, Bao-Qi
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2013, 21 (04): : 870 - 875
  • [7] The study on the measurement accuracy of non-steady state temperature field under different emissivity using infrared thermal image
    Shen, Jiuli
    Zhang, Yucun
    Xing, Tingting
    INFRARED PHYSICS & TECHNOLOGY, 2018, 94 : 207 - 213
  • [8] Full-field surface heat flux measurement using non-intrusive infrared thermography
    Rippe, Christian M.
    Lattimer, Brian Y.
    FIRE SAFETY JOURNAL, 2015, 78 : 238 - 250
  • [9] Infrared emissivity measurement based on polarized reflection characteristics of non-transmissive insulators
    Ogasawara, Nagahisa
    Saito, Junya
    Yamada, Hiroyuki
    MECHANICAL ENGINEERING JOURNAL, 2024, 11 (06):
  • [10] Measurement of infrared emissivity of surfaces with non-uniform millimeter-scale roughness
    Liu, Hua
    Ai, Qing
    Xia, Xin-Lin
    Wang, Zheng-Yu
    Zhang, Li-Na
    Yu, Ming-Xing
    Ai, Q. (hitaiqing@hit.edu.cn), 2013, Science Press (34): : 317 - 319