Ratiometric Molecular Sensor for Monitoring Oxygen Levels in Living Cells

被引:195
|
作者
Yoshihara, Toshitada [1 ]
Yamaguchi, Yuji [1 ]
Hosaka, Masahiro [2 ]
Takeuchi, Toshiyuki [3 ]
Tobita, Seiji [1 ]
机构
[1] Gunma Univ, Dept Chem & Biol Chem, Grad Sch Engn, Kiryu, Gunma 3768515, Japan
[2] Akita Prefectural Univ, Dept Biotechnol, Akita 0100195, Japan
[3] Gunma Univ, Maebashi, Gunma 3718510, Japan
基金
日本科学技术振兴机构;
关键词
biosensors; energy transfer; fluorescent probes; iridium; phosphorescence; ELECTRON-TRANSFER; TUMOR HYPOXIA; 2-PHOTON; MICROSCOPY; PROVIDES; DESIGN; ENERGY;
D O I
10.1002/anie.201107557
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A ratiometric oxygen sensor (C343-Pro 4-BTP) that uses coumarin343 (blue in picture) as an oxygen-insensitive fluorophore and an iridium complex (BTP, red in picture) as an oxygen-sensitive phosphor can be used to determine the oxygen concentration in solution and in living cells, which was demonstrated by ratiometric measurements of the blue coumarin343 fluorescence and the red BTP phosphorescence in C343-Pro 4-BTP (see picture). Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:4148 / 4151
页数:4
相关论文
共 50 条
  • [21] Lysosome-targeted ratiometric fluorescent sensor for monitoring pH in living cells based on one-pot-synthesized carbon dots
    Shaomei Xu
    Xu He
    Yibing Huang
    Xin Liu
    Lihe Zhao
    Xinghua Wang
    Ying Sun
    Pinyi Ma
    Daqian Song
    Microchimica Acta, 2020, 187
  • [22] Lysosome-targeted ratiometric fluorescent sensor for monitoring pH in living cells based on one-pot-synthesized carbon dots
    Xu, Shaomei
    He, Xu
    Huang, Yibing
    Liu, Xin
    Zhao, Lihe
    Wang, Xinghua
    Sun, Ying
    Ma, Pinyi
    Song, Daqian
    MICROCHIMICA ACTA, 2020, 187 (08)
  • [23] Ratiometric Fluorescent Probe for Monitoring Endogenous Methylglyoxal in Living Cells and Diabetic Blood Samples
    Wang, Huiling
    Xu, Yulin
    Rao, Li
    Yang, Chuntao
    Yuan, Hong
    Gao, Tingjuan
    Chen, Xin
    Sun, Hongyan
    Xian, Ming
    Liu, Chunrong
    Liu, Changlin
    ANALYTICAL CHEMISTRY, 2019, 91 (09) : 5646 - 5653
  • [24] A highly sensitive and genetically encoded fluorescent reporter for ratiometric monitoring of quinones in living cells
    Ji, Quanjiang
    Zhao, Boxuan Simen
    He, Chuan
    CHEMICAL COMMUNICATIONS, 2013, 49 (73) : 8027 - 8029
  • [25] ICT-based fluorescent ratiometric probe for monitoring mitochondrial peroxynitrite in living cells
    Du, Yuting
    Wang, Hongliang
    Zhang, Ting
    Wei, Wen
    Guo, Minmin
    NEW JOURNAL OF CHEMISTRY, 2021, 45 (29) : 12915 - 12921
  • [26] A FRET assembly of fluorescent gold nanoclusters for ratiometric monitoring peroxynitrite in living cells and zebrafish
    He, Shiyu
    Xiang, Hui
    Zhao, Gan
    Zhang, Mengting
    Lin, Jian
    Yang, Lina
    Liu, Honglin
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 378
  • [27] FRET excited ratiometric oxygen sensing in living tissue
    Ingram, Justin M.
    Zhang, Chunfeng
    Xu, Jian
    Schiff, Steven J.
    JOURNAL OF NEUROSCIENCE METHODS, 2013, 214 (01) : 45 - 51
  • [28] Development of a nanostructured sensor for monitoring oxidative stress in living cells
    Cipollina, Chiara
    Inguanta, Rosalinda
    Patella, Bernardo
    Buscetta, Marco
    Di Vincenzo, Serena
    Ferraro, Maria
    Sunseri, Carmelo
    Pace, Elisabetta
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [29] A ratiometric fluorescent sensor for pH fluctuation and its application in living cells with low dark toxicity
    Shi, Bingjie
    Gao, Yilin
    Liu, Chunxia
    Feng, Wei
    Li, Zhanxian
    Wei, Liuhe
    Yu, Mingming
    DYES AND PIGMENTS, 2017, 136 : 522 - 528
  • [30] Ratiometric Fluorescent Sensor Based on Inhibition of Resonance for Detection of Cadmium in Aqueous Solution and Living Cells
    Xue, Lin
    Li, Guoping
    Liu, Qing
    Wang, Huanhuan
    Liu, Chun
    Ding, Xunlei
    He, Shenggui
    Jiang, Hua
    INORGANIC CHEMISTRY, 2011, 50 (08) : 3680 - 3690