Ratiometric Fluorescent Sensor Based on Inhibition of Resonance for Detection of Cadmium in Aqueous Solution and Living Cells

被引:128
|
作者
Xue, Lin [1 ]
Li, Guoping [1 ,3 ]
Liu, Qing [1 ,3 ]
Wang, Huanhuan [1 ,3 ]
Liu, Chun [2 ]
Ding, Xunlei [1 ]
He, Shenggui [1 ]
Jiang, Hua [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
[2] Dalian Univ Technol, Dept Chem Engn, State Key Lab Fine Chem, Dalian 116012, Peoples R China
[3] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
ZINC IONS; BIOLOGICAL-SYSTEMS; MOLECULAR SENSOR; SPECIAL EMPHASIS; CD2+; CHEMOSENSOR; GENERATION; CARCINOGENESIS; METALS; PHOTOLUMINESCENCE;
D O I
10.1021/ic200032e
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Although cadmium has been recognized as a highly toxic heavy metal and poses many detrimental effects on human health, the Cd2+-uptake and nosogenesis mechanisms are still insufficiently understood, mainly because of the lack of facile analytical methods for monitoring changes in the environmental and intracellular Cd2+ concentrations with high spatial and temporal reliability. To this end, we present the design, synthesis, and photophysical properties of a cadmium sensor, DQCd1 based on the fluorophore 4-isobutoxy-6-(dimethylamino)-8-methoxyquinaldine (model compound 1). Preliminary investigations indicate that 1 could be protonated under neutral media and yield a resonance process over the quinoline fluorophore. Upon excitation at 405 nm, 1 shows a strong fluorescence emission at 554 nm with a quantum yield of 0.17. Similarly, DQCd1 bears properties comparable to its precursor. It exhibits fluorescence emission at 558 nm (Phi(f) = 0.15) originating from the monocationic species under physiological conditions. Coordination with Cd2+ causes quenching of the emission at 558 nm and simultaneously yields a significant hypsochromic shift of the emission maximum to 495 nm (Phi(f) = 0.11) due to inhibition of the resonance process. Thus, a single-excitation, dual-emission ratiometric measurement with a large blue shift in emission (Delta lambda = 63 nm) and remarkable changes in the ratio (F-495 nm/F-558 nm) of the emission intensity (R/R-0 up to 15-fold) is established. Moreover, the sensor DQCd1 exhibits very high sensitivity for Cd2+ (K-d = 41 pM) and excellent selectivity response for Cd2+ over other heavy- and transition-metal ions and Na+, K+, Mg2+ and Ca2+ at the millimolar level. Therefore, DQCd1 can act as a ratiometric fluorescent sensor for Cd2+ through inhibition of the resonance process. Confocal microscopy and cytotoxicity experiments indicate that DQCd1 is cell-permeable and noncytotoxic under our experimental conditions. It can indeed visualize the changes of intracellular Cd2+ in living cells using dual-emission ratiometry.
引用
收藏
页码:3680 / 3690
页数:11
相关论文
共 50 条
  • [1] Quinoline-based ratiometric fluorescent probe for detection of physiological pH changes in aqueous solution and living cells
    Liu, Zhen
    Li, Guoping
    Wang, Yana
    Li, Jiulong
    Mi, Yang
    Zou, Dapeng
    Li, Tiesheng
    Wu, Yangjie
    TALANTA, 2019, 192 : 6 - 13
  • [2] Diketopyrrolopyrrole-based novel ratiometric fluorescent chemodosimeter for Hg2+ detection in aqueous solution and in living cells
    Bi, Shiming
    Zhang, Guanjun
    Wu, Yue
    Wu, Shengying
    Wang, Limin
    DYES AND PIGMENTS, 2016, 134 : 586 - 592
  • [3] Colorimetric and ratiometric fluorescent detection of carbon monoxide in air, aqueous solution, and living cells by a naphthalimide-based probe
    Feng, Weiyong
    Hong, Jiaxin
    Feng, Guoqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 389 - 395
  • [4] A highly sensitive ratiometric fluorescent probe for Cd2+ detection in aqueous solution and living cells
    Liu, Zhipeng
    Zhang, Changli
    He, Weijiang
    Yang, Zhenghao
    Gao, Xiang
    Guo, Zijian
    CHEMICAL COMMUNICATIONS, 2010, 46 (33) : 6138 - 6140
  • [5] Ratiometric fluorescent and colorimetric BODIPY-based sensor for zinc ions in solution and living cells
    Xia, Shuai
    Shen, Jinjin
    Wang, Jianbo
    Wang, Hailong
    Fang, Mingxi
    Zhou, Hongwei
    Tanasova, Marina
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 258 : 1279 - 1286
  • [6] A charge transfer based ratiometric fluorescent probe for detection of hydrazine in aqueous medium and living cells
    Reja, Shahi Imam
    Gupta, Neha
    Bhalla, Vandana
    Kaur, Davinder
    Arora, Saroj
    Kumar, Manoj
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 923 - 929
  • [7] A pyrene-based fluorescent sensor for ratiometric detection of heparin and its complex with heparin for reversed ratiometric detection of protamine in aqueous solution
    Gong, Weiwei
    Wang, Shihuai
    Wei, Yuting
    Ding, Liping
    Fang, Yu
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 170 : 198 - 205
  • [8] A rhodamine-based fluorescent sensor for the highly selective and sensitive detection of mercury in aqueous solution and living cells
    Liu, Daying
    Qi, Jing
    Liu, Xiaoyan
    Cui, Zhigang
    Chang, Hexi
    Chen, Jiatong
    He, Huarui
    Yang, Guangming
    ANALYTICAL METHODS, 2014, 6 (11) : 3578 - 3581
  • [9] A highly selective fluorescent sensor for ratiometric detection of cyanide in aqueous solution and solid states
    Wang, Taisheng
    Shen, Lei
    Wang, Haoxiang
    Zhang, Na
    JOURNAL OF MOLECULAR STRUCTURE, 2021, 1231 (1231)
  • [10] A sensitive colorimetric and ratiometric fluorescent probe for mercury species in aqueous solution and living cells
    Jiang, Jie
    Liu, Wei
    Cheng, Ju
    Yang, Lizi
    Jiang, Huie
    Bai, Decheng
    Liu, Weisheng
    CHEMICAL COMMUNICATIONS, 2012, 48 (67) : 8371 - 8373