Ratiometric Molecular Sensor for Monitoring Oxygen Levels in Living Cells

被引:195
|
作者
Yoshihara, Toshitada [1 ]
Yamaguchi, Yuji [1 ]
Hosaka, Masahiro [2 ]
Takeuchi, Toshiyuki [3 ]
Tobita, Seiji [1 ]
机构
[1] Gunma Univ, Dept Chem & Biol Chem, Grad Sch Engn, Kiryu, Gunma 3768515, Japan
[2] Akita Prefectural Univ, Dept Biotechnol, Akita 0100195, Japan
[3] Gunma Univ, Maebashi, Gunma 3718510, Japan
基金
日本科学技术振兴机构;
关键词
biosensors; energy transfer; fluorescent probes; iridium; phosphorescence; ELECTRON-TRANSFER; TUMOR HYPOXIA; 2-PHOTON; MICROSCOPY; PROVIDES; DESIGN; ENERGY;
D O I
10.1002/anie.201107557
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A ratiometric oxygen sensor (C343-Pro 4-BTP) that uses coumarin343 (blue in picture) as an oxygen-insensitive fluorophore and an iridium complex (BTP, red in picture) as an oxygen-sensitive phosphor can be used to determine the oxygen concentration in solution and in living cells, which was demonstrated by ratiometric measurements of the blue coumarin343 fluorescence and the red BTP phosphorescence in C343-Pro 4-BTP (see picture). Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:4148 / 4151
页数:4
相关论文
共 50 条
  • [41] Mitochondria -targeted reversible ratiometric fluorescent probe for monitoring S02/HCHO in living cells
    Zhang, Tao
    Yin, Caixia
    Zhang, Yongbin
    Chao, Jianbin
    Wen, Guangming
    Huo, Fangjun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 234
  • [42] Construction of a dual-excitation ratiometric fluorescent probe for determining peroxynitrite levels in living cells and zebrafish
    Chen, Xi
    Wang, Yuan
    Zhao, Xiao-Lei
    Fan, Yun-Chang
    Bie, Hong-Yan
    Wu, Wei-Na
    Xu, Zhi-Hong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 313
  • [43] A molecular rotor based dual ratiometric sensor for heparinase
    Mudliar, Niyati H.
    Dongre, Prabhakar M.
    Singh, Prabhat K.
    DYES AND PIGMENTS, 2020, 181
  • [44] Monitoring of Peri-cellular Oxygen Levels in Tumor Cell Cultures by Amperometric Oxygen Sensor Array
    Kieninger, Jochen
    Aravindalochanan, Kuppusamy
    Urban, Gerald A.
    Sandvik, Joe A.
    Pettersen, Erik O.
    Jobst, Gerhard
    2010 IEEE SENSORS, 2010, : 1234 - 1237
  • [45] Ratiometric fluorescent biosensor for microRNAs imaging in living cells
    Zhou, Dongsheng
    Liu, Xueting
    Liu, Xiaotao
    Xu, Yuanteng
    Chen, Ruiqing
    Lin, Chang
    Guo, Liangqia
    Fu, Fengfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 322 (322):
  • [46] Ratiometric Fluorescent Probe for Imaging of Pantetheinase in Living Cells
    Hu, Yiming
    Li, Hongyu
    Shi, Wen
    Ma, Huimin
    ANALYTICAL CHEMISTRY, 2017, 89 (20) : 11107 - 11112
  • [47] Ratiometric fluorescence imaging for sodium selenite in living cells
    Tian, Yong
    Xin, Fangyun
    Jing, Jing
    Zhang, Xiaoling
    DYES AND PIGMENTS, 2019, 164 : 133 - 138
  • [48] Ratiometric Fluorescent Probe for the Detection of Glutathione in Living Cells
    Yang Runjie
    Tang Yao
    Zhu Weiping
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2016, 37 (04): : 643 - 647
  • [49] A molecular sensor detects signal transduction from caveolae in living cells
    Isshiki, M
    Ying, YS
    Fujita, T
    Anderson, RGW
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2002, 277 (45) : 43389 - 43398
  • [50] A Novel Ratiometric Oxygen Sensor Based On a Sextuple Hydrogen-Bonding Self-Assembly Molecular Heterodimer
    Zeng, Hui
    Zhang, Cheng
    Huang, Yan
    Lu, Zhiyun
    CHINESE JOURNAL OF CHEMISTRY, 2016, 34 (09) : 873 - 877