Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields

被引:27
|
作者
Kirov, AS
Williamson, JF
Meigooni, AS
Zhu, Y
机构
[1] Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St. Louis
关键词
heterogeneity corrections; Ir-192; HDR; TLD; Monte Carlo; detector artifacts;
D O I
10.1118/1.597733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Shields made of high atomic number material are commonly used in vaginal applicators with high dose-rate (HDR) (192)IR remotely afterloaded brachytherapy sources. However little data is available for the dose distribution around such shields. Heterogeneity correction factors (HCFs) are defined as the ratio of the dose to a point with the heterogeneity (shield) in place, divided by the dose to the same point with no heterogeneity. Using thermoluminescent dosimeters (TLDs) in solid water phantom we have measured the HCFs behind 6 and 20 mm diam tungsten alloy disks, 4 and 2 mm thick and a 4 mm thick steel disk, positioned 15 mm from the source. For each measurement point, the heterogeneity correction factors were also inferred from Monte Carlo simulations, which accurately modeled the experimental geometry. The agreement between measured and calculated HCFs on the average was within 6%. Tungsten alloy disks resulted in about two times greater dose reduction in water (HCF approximate to 0.4, for 20X4 mm disk) than for a steel disk with the same dimensions (HCF approximate to 0.85). Reducing the disk diameter to 6 mm increased the dose transmission up to about 25%. Increasing the source-to-detector distance from 4 to 7 cm caused a change in HCF from 2% to more than 20%, depending on disk material and diameter. The detector artifact effects arising from the finite size and different composition of the TLD chips were determined. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 50 条
  • [41] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [42] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [43] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [44] Verification of high dose rate 192Ir source position during brachytherapy treatment
    Batic, M.
    Burger, J.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Mikuz, M.
    Studen, A.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 206 - 208
  • [45] Small dimension plastic dosimeter in High Dose Rate Brachytherapy with 192Ir source
    Rego, Florbela
    Ribeiro, Tiago Ramos
    Peralta, Luis
    Jesus, Carlos
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 249 - 252
  • [46] Lack of the Dose-Rate Effect of 192Ir Source Activity on Pelvic Control and Late Complications After High-Dose-Rate Brachytherapy for Cervical Cancer
    Chen, Shang-Wen
    Liang, Ji-An
    Shiau, An-Chang
    Yu, Chun-Yen
    Hung, Yao-Ching
    Yeh, Lian-Shung
    Chang, Wei-Chun
    Lin, Wu-Chou
    Yang, Shih-Neng
    Lin, Fang-Jen
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 173 - 179
  • [47] Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source
    Harpool, K.
    Herman, T. De la Fuente
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3468 - 3468
  • [48] Tumor Control and Normal Tissue Complications in High-dose-rate Brachytherapy for Cervical Cancer Patients Using Ir-192 Radioactive Source
    Kaur, Gurpreet
    Garg, Pardeep
    Dangwal, Vinod Kumar
    Singh, Baltej
    Gaur, Garima
    Grover, Romikant
    Singh, Simrandeep
    Sharma, Rachana
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 363 - 369
  • [49] Optimization of the energy window setting in Ir-192 source imaging for high-dose-rate brachytherapy using a YAP(Ce) gamma camera
    Nagata, Jura
    Nakanishi, Kohei
    Yamamoto, Seiichi
    Yabe, Takuya
    Yogo, Katsunori
    Noguchi, Yumiko
    Okudaira, Kuniyasu
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 103 : 66 - 73
  • [50] Measurement and calculation of the dose at large distances from brachytherapy sources: Cs-137, Ir-192, and Co-60
    Venselaar, JLM
    vanderGiessen, PH
    Dries, WJF
    MEDICAL PHYSICS, 1996, 23 (04) : 537 - 543