Tumor Control and Normal Tissue Complications in High-dose-rate Brachytherapy for Cervical Cancer Patients Using Ir-192 Radioactive Source

被引:0
|
作者
Kaur, Gurpreet [1 ]
Garg, Pardeep [1 ]
Dangwal, Vinod Kumar [3 ]
Singh, Baltej [2 ]
Gaur, Garima [1 ]
Grover, Romikant [1 ]
Singh, Simrandeep [1 ]
Sharma, Rachana [4 ]
机构
[1] Guru Gobind Singh Med Coll & Hosp, Dept Radiat Oncol, Faridkot, India
[2] Guru Gobind Singh Med Coll & Hosp, Dept Community Med, Faridkot, India
[3] Govt Med Coll, Dept Radiat Oncol, Patiala, Punjab, India
[4] Guru Nanak Dev Univ, Dept Sociol, Amritsar, Punjab, India
关键词
Brachytherapy; carcinoma uterine cervix; normal tissue complication probability; radiotherapy; tumor control probability; SOCIETY CONSENSUS GUIDELINES; LOCALLY ADVANCED-CARCINOMA; AMERICAN BRACHYTHERAPY; RECOMMENDATIONS; RADIATION; EMPHASIS;
D O I
10.4103/jmp.jmp_86_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The purpose of the study was to calculate, tumor control probability (TCP) and normal tissue complication probability (NTCP) in cervical cancer patients and to clinically correlate the outcomes with a follow-up period of 24 months. Materials and Methods: One hundred and fifty patients were included in the present study who received 46 Gy/23 fractions/4 1/2 weeks of external beam radiotherapy with concurrent cisplatin chemotherapy, followed by intracavitary brachytherapy of 3 different fractionations regimens, i.e., 9.5 Gy per fraction of two fractions (50 patients in Arm1), 7.5 Gy per fraction of three fractions (50 patients in Arm2), and 6.0 Gy per fraction of four fractions (50 patients in Arm3). Results: The median TCP value for Arm1, Arm2, and Arm3 was 99.6%, 94%, and 98.1%, respectively, (P < 0.01). The median NTCP value for bladder in Arm1, Arm2, and Arm3 was 0.17%, 0.04%, and 0.07%, respectively, (P = 0.05). The median NTCP value for rectum in Arm1, Arm2, and Arm3 was 4.73%, 4.35%, and 3.17%, respectively, (P = 0.052). The overall survival (OS) of 90%, 86%, and 84% was found for Arm1, Arm2, and Arm3, respectively, at 24 months of follow-up. Conclusion: TCP, NTCP, and OS rates were found higher in Arm1 as compared to the other two arms. The complications found in all arms were less, low grade, and manageable. Hence, Arm1, i.e., 9.5 Gy per fraction of two fractions can be concluded as the optimum fractionation regime in terms of radiobiological parameters as well as overall patient comfort.
引用
收藏
页码:363 / 369
页数:7
相关论文
共 50 条
  • [1] Imaging of Ir-192 source using a high energy gamma camera for high-dose-rate brachytherapy
    Yamamoto, Seiichi
    Yogo, Katsunori
    Noguchi, Yumiko
    Nakaya, Takayoshi
    Okudaira, Kuniyasu
    RADIATION MEASUREMENTS, 2019, 126
  • [2] Impact of different Ir-192 source models on dose calculations in high-dose-rate brachytherapy
    Otani, Yuki
    Shimamoto, Shigetoshi
    Sumida, Iori
    Takahashi, Yutaka
    Tani, Shoji
    Oshima, Tetsuya
    Onosaka, Satoshi
    Isohashi, Fumiaki
    Tamari, Keisuke
    Ogawa, Kazuhiko
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 7 : 23 - 26
  • [3] Trials of transmission imaging using clinically used Ir-192 source for high-dose-rate brachytherapy
    Nagata, J.
    Yamamoto, S.
    Nakanishi, K.
    Noguchi, Y.
    Okudaira, K.
    Kataoka, J.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (06)
  • [4] Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source
    Sharma, SD
    Bianchi, C
    Conte, L
    Novario, R
    Bhatt, BC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17): : 4065 - 4072
  • [5] Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization
    Gay, H. A.
    Allison, R. R.
    Downie, G. H.
    Mota, H. C.
    Austerlitz, C.
    Jenkins, T.
    Sibata, C. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 2987 - 2999
  • [6] Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    Wong, TPY
    Fernando, W
    Johnston, PN
    Bubb, IF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 323 - 331
  • [7] Lack of the Dose-Rate Effect of 192Ir Source Activity on Pelvic Control and Late Complications After High-Dose-Rate Brachytherapy for Cervical Cancer
    Chen, Shang-Wen
    Liang, Ji-An
    Shiau, An-Chang
    Yu, Chun-Yen
    Hung, Yao-Ching
    Yeh, Lian-Shung
    Chang, Wei-Chun
    Lin, Wu-Chou
    Yang, Shih-Neng
    Lin, Fang-Jen
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 173 - 179
  • [8] ANISOTROPY MEASUREMENTS OF A HIGH-DOSE-RATE IR-192 SOURCE IN AIR AND IN POLYSTYRENE
    MULLERRUNKEL, R
    CHO, SH
    MEDICAL PHYSICS, 1994, 21 (07) : 1131 - 1134
  • [9] INTERSTITIAL HIGH-DOSE-RATE BRACHYTHERAPY WITH IR-192 IN PATIENTS WITH ORAL SQUAMOUS-CELL CARCINOMA
    FRIEDRICH, RE
    KRULL, A
    HELLNER, D
    SCHWARZ, R
    HEYER, D
    PLAMBECK, K
    SCHMELZLE, R
    JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (04): : 238 - 242
  • [10] Calibration of Ir-192 high dose rate brachytherapy source using different calibration procedures
    Bondel, Shwetha
    Ravikumar, Manickham
    Supe, Sanjay Sudhakar
    Reddy, Buchuppudi Rekha
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (03) : 151 - 156