Evaluation of X-ray fluorescence spectroscopy as a method for the rapid and direct determination of sodium in cheese

被引:16
|
作者
Stankey, J. A. [1 ]
Akbulut, C. [1 ]
Romero, J. E. [1 ]
Govindasamy-Lucey, S. [1 ]
机构
[1] Univ Wisconsin, Wisconsin Ctr Dairy Res, Madison, WI 53706 USA
关键词
sodium; X-ray fluorescence spectroscopy; cheese; MICROWAVE DIGESTION; MILK-PRODUCTS; FOOD; SPECTROMETRY; VALIDATION; ELEMENTS; SALT; ICP;
D O I
10.3168/jds.2014-9055
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Cheese manufacturers indirectly determine Na in cheese by analysis of Cl using the Volhard method, assuming that all Cl came from NaCl. This method overestimates the actual Na content in cheeses when Na replacers (e.g., KCl) are used. A direct and rapid method for Na detection is needed. X-ray fluorescence spectroscopy (XRF), a mineral analysis technique used in the mining industry, was investigated as an alternative method of Na detection in cheese. An XRF method for the detection of Na in cheese was developed and compared with inductively coupled plasma optical emission spectroscopy (ICP-OES; the reference method for Na in cheese) and Cl analyzer. Sodium quantification was performed by multi-point calibration with cheese standards spiked with NaCl ranging from 0 to 4% Na (wt/wt). The Na concentration of each of the cheese standards (discs: 30 mm x 7 mm) was quantified by the 3 methods. A single laboratory method validation was performed; linearity, precision, limit of detection, and limit of quantification were determined. An additional calibration graph was created using cheese standards made from natural or process cheeses manufactured with different ratios of Na:K. Both Na and K calibration curves were linear for the cheese standards. Sodium was quantified in a variety of commercial cheese samples. The Na data obtained by XRF were in agreement with those from ICP-OES and Cl analyzer for most commercial natural cheeses. The XRF method did not accurately determine Na concentration for several process cheese samples, compared with ICP-OES, likely due to the use of unknown types of Na-based emulsifying salts (ES). When a calibration curve was created for process cheese with the specific types of ES used for this cheese, Na content was successfully predicted in the samples. For natural cheeses, the limit of detection and limit of quantification for Na that can be determined with an acceptable level of repeatability, precision, and trueness was 82 and 246 mg/100 g of cheese, respectively. Calibration graphs should be created with standards that reflect the concentration range, ratio, and salt type present in the cheeses. This XRF method can be successfully used for the rapid and direct measurement of Na content in a wide variety of natural cheeses. Commercial process cheese manufacturers use proprietary blends of ES. We did find that the XRF technique worked for process cheese when the calibration graphs were created with the specific types of ES actually used.
引用
收藏
页码:5040 / 5051
页数:12
相关论文
共 50 条
  • [31] Direct determination of cadmium speciation in municipal solid waste fly ashes by synchrotron radiation induced μ-X-ray fluorescence and μ-X-ray absorption spectroscopy
    Pinzani, MCC
    Somogyi, A
    Simionovici, AS
    Ansell, S
    Steenari, BM
    Lindqvist, O
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (14) : 3165 - 3169
  • [32] A RAPID METHOD FOR THE EVALUATION OF THE GLUCOSINOLATE QUALITY OF EXTRACTED RAPESEED MEAL BY TOTAL SULFUR DETERMINATION VIA X-RAY-FLUORESCENCE SPECTROSCOPY
    SCHNUG, E
    HANEKLAUS, S
    FETT WISSENSCHAFT TECHNOLOGIE-FAT SCIENCE TECHNOLOGY, 1990, 92 (02): : 57 - 61
  • [33] Portable X-Ray Fluorescence Spectroscopy for Rapid and Cost-Effective Determination of Elemental Composition of Ground Forage
    Sapkota, Yadav
    McDonald, Louis M.
    Griggs, Thomas C.
    Basden, Thomas J.
    Drake, Brandon Lee
    FRONTIERS IN PLANT SCIENCE, 2019, 10
  • [34] Rapid Determination of Trace Elements in Water by Total Reflection X-Ray Fluorescence Spectrometry Using Direct Sampling
    Wu Lei
    Li Ling-yun
    Peng Yong-zhen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (03) : 990 - 996
  • [35] Indirect method for the determination of x-ray tube primary spectra: application to x-ray fluorescence analysis
    Delgado, V
    X-RAY SPECTROMETRY, 2002, 31 (05) : 353 - 357
  • [36] RAPID DETERMINATION OF SILVER IN ORES BY X-RAY FLUORESCENCE SPECTROMETRY WITH INTERNAL STANDARD METHOD USING PALLADIUM
    TAKIZAWA, M
    ETO, T
    JAPAN ANALYST, 1970, 19 (10): : 1411 - &
  • [37] A rapid method for the indirect determination of the clay content by X-ray fluorescence spectroscopic analysis of rubidium in soils
    Schnug, E
    Haneklaus, S
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1996, 27 (5-8) : 1707 - 1719
  • [38] Handheld x-ray fluorescence spectroscopy evaluation of leather chromium and cobalt
    Artounian, K.
    Hamann, D.
    OCCUPATIONAL MEDICINE-OXFORD, 2021, 71 (6-7): : 298 - 300
  • [39] Direct determination of mineral nutrients in soybean leaves under vivo conditions by portable X-ray fluorescence spectroscopy
    Costa Junior, Geovani Tadeu
    Nunes, Lidiane Cristina
    Feresin Gomes, Marcos Henrique
    de Almeida, Eduardo
    Pereira de Carvalho, Hudson Wallace
    X-RAY SPECTROMETRY, 2020, 49 (02) : 274 - 283
  • [40] Particle dynamics by a new method of x-ray fluorescence correlation spectroscopy
    Sood, AK
    Wang, J
    Satyam, PV
    Feng, YP
    Wu, XZ
    Cai, ZH
    Yun, WB
    Sinha, SK
    STRUCTURE AND DYNAMICS OF MATERIALS IN THE MESOSCOPIC DOMAIN, 1999, : 26 - 36