Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192Ir brachytherapy sources

被引:13
|
作者
Kaveckyte, Vaiva [1 ]
Malusek, Alexandr [1 ]
Benmakhlouf, Hamza [2 ]
Carlsson, Gudrun Alm [1 ]
Tedgren, Asa Carlsson [1 ,2 ]
机构
[1] Linkoping Univ, Dept Med & Hlth Sci, Radiat Phys, SE-58185 Linkoping, Sweden
[2] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
关键词
brachytherapy; dosimetry; Iridium-192; microDiamond detector; radiation detectors; CRYSTAL DIAMOND DETECTOR; PHOTON ENERGIES RELEVANT; HDR BRACHYTHERAPY; RATE DEPENDENCE; THERMOLUMINESCENT DOSIMETERS; ELECTRON-BEAMS; RADIATION; MOSFET; PROTOCOL; SPECTRA;
D O I
10.1002/mp.12694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Experimental dosimetry of high-dose-rate (HDR) Ir-192 brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high sensitivity, direct readout, and nearly water-equivalent active volume. The purpose of this study was to evaluate the suitability of microDiamond detectors for the determination of absorbed dose to water around HDR Ir-192 BT sources. Three microDiamond detectors were used, allowing for the comparison of their properties. Methods: In-phantom measurements were performed using microSelectron and VariSource iX HDR Ir-192 BT treatment units. Their treatment planning systems (TPSs), Oncentra (v. 4.3) and BrachyVision (v. 13.6), respectively, were used to create irradiation plans for a cubic PMMA phantom with the microDiamond positioned at one of three source-to-detector distances (SDDs) (1.5, 2.5, and 5.5 cm) at a time. The source was stepped in increments of 0.5 cm over a total length of 6 cm to yield absorbed dose of 2 Gy at the nominal reference-point of the detector. Detectors were calibrated in Co-60 beam in terms of absorbed dose to water, and Monte Carlo (MC) calculated beam quality correction factors were applied to account for absorbed-dose energy dependence. Phantom correction factors were applied to account for differences in dimensions between the measurement phantom and a water phantom used for absorbed dose calculations made with a TPS. The same measurements were made with all three of the detectors. Additionally, dose-rate dependence and stability of the detectors were evaluated in Co-60 beam. Results: The percentage differences between experimentally determined and TPS-calculated absorbed doses to water were from -1.3% to +2.9%. The values agreed to within experimental uncertainties, which were from 1.9% to 4.3% (k = 2) depending on the detector, SDD and treatment delivery unit. No dose-rate or intrinsic energy dependence corrections were applied. All microDiamonds were comparable in terms of preirradiation dose, stability of the readings and energy response, and showed a good agreement. Conclusions: The results indicate that the microDiamond is potentially suitable for the determination of absorbed dose to water around HDR Ir-192 BT sources and may be used for independent verification of TPS's calculations, as well as for QA measurements of HDR Ir-192 BT treatment delivery units at clinical sites. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:429 / 437
页数:9
相关论文
共 50 条
  • [41] Using LiF:Mg, Cu, P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source
    Lucas, P. Aviles
    Aubineau-Laniece, I.
    Lourenco, V.
    Vermesse, D.
    Cutarella, D.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [42] An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry:: Numerical and experimental proof-of-principle
    Sarfehnia, Arman
    Stewart, Kristin
    Seuntjensb, Jan
    MEDICAL PHYSICS, 2007, 34 (12) : 4957 - 4961
  • [43] A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources
    deAlmeida, Carlos Eduardo
    Ochoa, Ricardo
    de Lima, Marilene Coelho
    David, Mariano Gazineu
    Pires, Evandro Jesus
    Peixoto, Jose Guilherme
    Salata, Camila
    Bernal, Mario Antonio
    PLOS ONE, 2014, 9 (12):
  • [44] Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer
    Wen, Aiping
    Wang, Xianliang
    Wang, Bingjie
    Yan, Chuanjun
    Luo, Jingyue
    Wang, Pei
    Li, Jie
    CANCERS, 2022, 14 (19)
  • [45] A practical implementation of the 2010 IPEM high dose rate brachytherapy code of practice for the calibration of 192Ir sources
    Awunor, O. A.
    Lecomber, A. R.
    Richmond, N.
    Walker, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5397 - 5410
  • [46] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 413 - 422
  • [47] Dosimetric study of Varian Universal Multi-Channel Cylinder System for High-Dose-Rate 192Ir Brachytherapy
    Tien, Christopher J.
    Damast, Shari
    Chen, Zhe
    BRACHYTHERAPY, 2022, 21 (02) : 244 - 254
  • [48] Determination of Dose at the Reference Point for 192Ir HDR Brachytherapy Sources Using Fricke Dosimetry
    Austerlitz, Carlos
    Benhabib, Sidi
    Zhu, Dengsong
    Mota, Helvecio
    Campos, Diana
    Allison, Ron
    Sibina, Claudio
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (06): : 617 - 617
  • [49] Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors
    Zilio, Valery Olivier
    Joneja, Om Parkash
    Popowski, Youri
    Rosenfeld, Anatoly
    Chawla, Rakesh
    MEDICAL PHYSICS, 2006, 33 (06) : 1532 - 1539
  • [50] Small dimension plastic dosimeter in High Dose Rate Brachytherapy with 192Ir source
    Rego, Florbela
    Ribeiro, Tiago Ramos
    Peralta, Luis
    Jesus, Carlos
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 249 - 252