Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192Ir brachytherapy sources

被引:13
|
作者
Kaveckyte, Vaiva [1 ]
Malusek, Alexandr [1 ]
Benmakhlouf, Hamza [2 ]
Carlsson, Gudrun Alm [1 ]
Tedgren, Asa Carlsson [1 ,2 ]
机构
[1] Linkoping Univ, Dept Med & Hlth Sci, Radiat Phys, SE-58185 Linkoping, Sweden
[2] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
关键词
brachytherapy; dosimetry; Iridium-192; microDiamond detector; radiation detectors; CRYSTAL DIAMOND DETECTOR; PHOTON ENERGIES RELEVANT; HDR BRACHYTHERAPY; RATE DEPENDENCE; THERMOLUMINESCENT DOSIMETERS; ELECTRON-BEAMS; RADIATION; MOSFET; PROTOCOL; SPECTRA;
D O I
10.1002/mp.12694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Experimental dosimetry of high-dose-rate (HDR) Ir-192 brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high sensitivity, direct readout, and nearly water-equivalent active volume. The purpose of this study was to evaluate the suitability of microDiamond detectors for the determination of absorbed dose to water around HDR Ir-192 BT sources. Three microDiamond detectors were used, allowing for the comparison of their properties. Methods: In-phantom measurements were performed using microSelectron and VariSource iX HDR Ir-192 BT treatment units. Their treatment planning systems (TPSs), Oncentra (v. 4.3) and BrachyVision (v. 13.6), respectively, were used to create irradiation plans for a cubic PMMA phantom with the microDiamond positioned at one of three source-to-detector distances (SDDs) (1.5, 2.5, and 5.5 cm) at a time. The source was stepped in increments of 0.5 cm over a total length of 6 cm to yield absorbed dose of 2 Gy at the nominal reference-point of the detector. Detectors were calibrated in Co-60 beam in terms of absorbed dose to water, and Monte Carlo (MC) calculated beam quality correction factors were applied to account for absorbed-dose energy dependence. Phantom correction factors were applied to account for differences in dimensions between the measurement phantom and a water phantom used for absorbed dose calculations made with a TPS. The same measurements were made with all three of the detectors. Additionally, dose-rate dependence and stability of the detectors were evaluated in Co-60 beam. Results: The percentage differences between experimentally determined and TPS-calculated absorbed doses to water were from -1.3% to +2.9%. The values agreed to within experimental uncertainties, which were from 1.9% to 4.3% (k = 2) depending on the detector, SDD and treatment delivery unit. No dose-rate or intrinsic energy dependence corrections were applied. All microDiamonds were comparable in terms of preirradiation dose, stability of the readings and energy response, and showed a good agreement. Conclusions: The results indicate that the microDiamond is potentially suitable for the determination of absorbed dose to water around HDR Ir-192 BT sources and may be used for independent verification of TPS's calculations, as well as for QA measurements of HDR Ir-192 BT treatment delivery units at clinical sites. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:429 / 437
页数:9
相关论文
共 50 条
  • [31] Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources
    Farhood B.
    Ghorbani M.
    Radiological Physics and Technology, 2017, 10 (4) : 454 - 463
  • [32] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +
  • [33] Dosimetric comparison of brachytherapy sources for high-dose-rate treatment of endometrial cancer: 192Ir, 60Co and an electronic brachytherapy source
    Mobit, Paul N.
    Nguyen, Alex
    Packianathan, Satyaseelan
    He, Rui
    Yang, Claus C.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1059):
  • [34] A comparison of the biological effective dose of 50-kV electronic brachytherapy with 192Ir high-dose-rate brachytherapy for vaginal cuff irradiation
    Rava, Paul
    Dvorak, Tomas
    Markelewicz, Robert J., Jr.
    Hiatt, Jessica R.
    Sternick, Edward S.
    MacAusland, Stephanie G.
    Huber, Kathryn
    Wazer, David E.
    Hepel, Jaroslaw T.
    BRACHYTHERAPY, 2012, 11 (05) : 402 - 407
  • [35] Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium
    Fonseca, Gabriel Paiva
    Tedgren, Asa Carlsson
    Reniers, Brigitte
    Nilsson, Josef
    Persson, Maria
    Yoriyaz, Helio
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : 4565 - 4579
  • [36] Development of a water calorimetry-based standard for absorbed dose to water in HDR 192Ir brachytherapy
    Sarfehnia, Arman
    Seuntjens, Jan
    MEDICAL PHYSICS, 2010, 37 (04) : 1914 - 1923
  • [37] On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy
    Therriault-Proulx, Francois
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2013, 40 (06)
  • [38] Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source
    Gifford, Kent A.
    Price, Michael J.
    Horton, John L., Jr.
    Wareing, Todd A.
    Mourtada, Firas
    MEDICAL PHYSICS, 2008, 35 (06) : 2279 - 2285
  • [39] Patient effective dose from endovascular brachytherapy with 192Ir sources
    Perna, L
    Bianchi, C
    Nicolini, G
    Novario, R
    Tanzi, F
    Conte, L
    RADIATION PROTECTION DOSIMETRY, 2002, 102 (02) : 121 - 128
  • [40] Dose modification factors for 192Ir high-dose-rate irradiation using Monte Carlo simulations
    Kassas, Bassel
    Mourtada, Firas
    Horton, John L.
    Lane, Richard G.
    Buchholz, Thomas A.
    Strom, Eric A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (03): : 28 - 34