Simultaneous absorbance, fluorescence and refractive index (SAFRIN) detection for Micro LC

被引:7
|
作者
Abbas, AA
Shelly, DC [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
[2] Microfusilon, Lubbock, TX 79423 USA
关键词
absorbance; fluorescence; refractive index; Micro LC;
D O I
10.1016/S0003-2670(99)00404-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Absorbance, fluorescence and refractive index detection are simultaneously accomplished in a Micro LC system. A unique double eccentric-bend fused silica capillary is employed with axial illumination to achieve a long path length, multisensing flow cell. Two different optical sources, one that excites fluorescence through absorption and one that is not absorbed by eluting analytes, are imaged into the bends with optical fibers, placed within the capillary lumen in separate legs of the device. Axially-propagating light exits at each bend where photodetectors simultaneously collect attenuated light, one signal based on absorption and the other signal based on refractive index. A nearby cylindrical lens, optical filter and photomultiplier tube collect fluorescence in the 'absorption' leg of the capillary. Thus, trifunctional detection is achieved in microscale liquid chromatography. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 205
页数:15
相关论文
共 50 条
  • [41] Simultaneous Determination of Safingol and d-erythro-Sphinganine in Human Plasma by LC with Fluorescence Detection
    Lee, Joo-Sang
    Singh, Hardeep
    Maurer, Barry J.
    Reynolds, C. Patrick
    Kang, Min H.
    CHROMATOGRAPHIA, 2010, 71 (11-12) : 1087 - 1091
  • [42] Simultaneous determination of eprinomectin, moxidectin, abamectin, doramectin, and ivermectin in beef liver by LC with fluorescence detection
    Ali, MS
    Sun, T
    McLeroy, GE
    Phillippo, ET
    JOURNAL OF AOAC INTERNATIONAL, 2000, 83 (01) : 31 - 38
  • [43] Simultaneous Determination of Safingol and d-erythro-Sphinganine in Human Plasma by LC with Fluorescence Detection
    Joo-Sang Lee
    Hardeep Singh
    Barry J. Maurer
    C. Patrick Reynolds
    Min H. Kang
    Chromatographia, 2010, 71 : 1087 - 1091
  • [44] The true refractive index correction to the fluorescence intensity in the commercial fluorescence spectrophotometer
    Kotelevskiy, SI
    JOURNAL OF LUMINESCENCE, 1998, 79 (03) : 211 - 214
  • [45] Simultaneous Quantification of Aliskiren, Valsartan and Sitagliptin by LC with Fluorescence Detection: Evidence of Pharmacokinetic Interaction in Rats
    Vishal Goyani
    Rajeshwari Rathod
    Ranjeet Prasad Dash
    Manish Nivsarkar
    Chromatographia, 2013, 76 : 515 - 521
  • [46] Simultaneous Detection of Refractive Index and Temperature in Terahertz Band Based on Electromagnetic Induced Transparency Effect
    Ma, Yi
    Huang, Lihao
    Wang, Xiugui
    Chen, Lin
    IEEE SENSORS JOURNAL, 2023, 23 (19) : 22476 - 22485
  • [47] AXIAL ILLUMINATION OF FUSED-SILICA CAPILLARIES - INVESTIGATION OF FLUORESCENCE AND REFRACTIVE-INDEX DETECTION
    ABBAS, AA
    SHELLY, DC
    JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2): : 133 - 144
  • [48] Tolerance analysis of a micro-optical detection unit for fluorescence and absorbance measurements in lab-on-a-chip micro-channels for chromatographic applications
    Van Overmeire, Sara
    Ottevaere, Heidi
    Desmet, Gert
    Thienpont, Hugo
    BIOSENSING, 2008, 7035
  • [49] Miniaturized detection system for fluorescence and absorbance measurements in chromatographic applications
    Van Overmeire, Sara
    Ottevaere, Heidi
    Desmet, Gert
    Thienpont, Hugo
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2008, 14 (01) : 140 - 150
  • [50] Simultaneous measurement of refractive index and thickness with a convergent beam
    King Ung Hii
    Kuan Hiang Kwek
    Optical Review, 2014, 21 : 705 - 708