A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations

被引:15
|
作者
Fernandez, Monica A. [1 ]
de Mendoza, Carmen Y. Paez [2 ]
Platt, Jeffrey A. [3 ]
Levon, John A. [4 ]
Hovijitra, Suteera T. [2 ]
Nimmo, Arthur [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Restorat Dent Sci, Div Prosthodont, Gainesville, FL 32610 USA
[2] Indiana Univ, Sch Dent, Dept Restorat Dent, Indianapolis, IN USA
[3] Indiana Univ, Sch Dent, Indianapolis, IN USA
[4] Indiana Univ, Sch Dent, Adv Educ Program Prosthodont, Indianapolis, IN USA
关键词
Implant; impressions; jig; gap; screw test; prosthetic framework; misfit; FIXED PARTIAL DENTURES; MASTER CAST ACCURACY; OSSEOINTEGRATED IMPLANTS; GYPSUM CASTS; PROSTHODONTICS; REPLACEMENT; STONE; DIES;
D O I
10.1111/jopr.12015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A precise transfer of the position and orientation of the antirotational mechanism of an implant to the working cast is particularly important to achieve optimal fit of the final restoration. This study evaluated and compared the accuracy of metal and plastic impression copings for use in a full-arch mandibular edentulous simulation with four implants. Materials and Methods Metal and plastic impression transfer copings for two implant systems, Nobel Biocare Replace and Straumann SynOcta (R), were assessed on a laboratory model to simulate clinical practice. The accuracy of producing stone casts using these plastic and metal impression transfer copings was measured against a standard prosthetic framework consisting of a cast gold bar. A total of 20 casts from the four combinations were obtained. The fit of the framework on the cast was tested by a noncontact surface profilometer, the Proscan 3D 2000 A, using the one-screw test. The effects of implant/system and impression/coping material on gap measurements were analyzed using repeated measures ANOVA. Results The findings of this in vitro study were as follows: plastic copings demonstrated significantly larger average gaps than metal for Straumann (p = 0.001). Plastic and metal copings were not significantly different for Nobel (p = 0.302). Nobel had significantly larger average gaps than Straumann for metal copings (p = 0.003). Nobel had marginally smaller average gaps than Straumann (p = 0.096) for plastic copings. The system-by-screw location interaction was significant as well (p < 0.001), indicating significant differences among the four screw locations, but the location differences were not the same for the two systems. A rank transformation of the data was necessary due to the nonnormal distribution of the gap measurements. No adjustments were made for multiple comparisons. Conclusions The metal impression copings were more accurate than plastic copings when using the Straumann system, and there was no difference between metal and plastic copings for the Nobel Replace system. The system-by-screw location was not conclusive, showing no correlation within each system
引用
收藏
页码:367 / 376
页数:10
相关论文
共 50 条
  • [21] MAKING AN IMPLANT-LEVEL IMPRESSION USING SOLID PLASTIC, PRESS-FIT, CLOSED-TRAY IMPRESSION COPINGS: A CLINICAL REPORT
    Selecman, Audrey M.
    Wicks, Russell A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (03): : 158 - 159
  • [22] Accuracy of a proposed implant impression technique using abutments and metal framework
    Lee, Hyeok-Jae .
    Lim, Young-Jun
    Kim, Chang-Whe
    Choi, Jung-Han
    Kim, Myung-Joo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (01): : 25 - 31
  • [23] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [24] Accuracy of Interchangeable Implant Impression Systems: An In Vitro Pilot Study
    Aldosari, Abdullah M. AlFarraj
    AlBaker, Abdulaziz M.
    AlShihri, Abdulmonem A.
    AlJadeed, Majid I.
    AlBwardi, Loay A.
    Anil, Sukumaran
    IMPLANT DENTISTRY, 2015, 24 (03) : 317 - 322
  • [25] Comparative Evaluation of the Rigidity and Accuracy of Different Elastomeric Impression Materials with Open Tray Implant Level Impression Technique-An In vitro Study
    Aidasani, Ashwin N.
    Jain, Shailesh
    Hassan, Sahba
    Sharma, Anu
    Shanthi, C.
    Fere, Sandeep
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1262 - S1265
  • [26] Comparative Study of the Polyvinyl Siloxane Technique With Resin-Splinted Transfer Copings Used for Multiple Implant Abutment Impressions
    Ferreira, Vinicius F.
    Barboza, Eliane P.
    Gouvea, Cresus Vinicius D.
    Bianchini, Guilherme M.
    Mussallem, Flavio
    Carvalho, Waldimir R.
    IMPLANT DENTISTRY, 2012, 21 (01) : 72 - 76
  • [27] TRANSFER IMPRESSION FOR ACCURATE ADJUSTMENT OF A METAL COPING INSERT FOR THE SUBMERGED IMPLANT
    BURNS, DR
    CRABTREE, DG
    BELL, DH
    JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (04): : 484 - 487
  • [28] A Method for Obtaining Peri-Implant Soft-Tissue Contours by Using Screw-Retained Provisional Restorations as Impression Copings: A Clinical Report
    Tsai, Bi-Yuan
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (05) : 605 - 609
  • [29] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [30] Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy
    Akalin, Zerrin Fidan
    Ozkan, Yasemin Kulak
    Ekerim, Ahmet
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 149 - 157