A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations

被引:15
|
作者
Fernandez, Monica A. [1 ]
de Mendoza, Carmen Y. Paez [2 ]
Platt, Jeffrey A. [3 ]
Levon, John A. [4 ]
Hovijitra, Suteera T. [2 ]
Nimmo, Arthur [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Restorat Dent Sci, Div Prosthodont, Gainesville, FL 32610 USA
[2] Indiana Univ, Sch Dent, Dept Restorat Dent, Indianapolis, IN USA
[3] Indiana Univ, Sch Dent, Indianapolis, IN USA
[4] Indiana Univ, Sch Dent, Adv Educ Program Prosthodont, Indianapolis, IN USA
关键词
Implant; impressions; jig; gap; screw test; prosthetic framework; misfit; FIXED PARTIAL DENTURES; MASTER CAST ACCURACY; OSSEOINTEGRATED IMPLANTS; GYPSUM CASTS; PROSTHODONTICS; REPLACEMENT; STONE; DIES;
D O I
10.1111/jopr.12015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A precise transfer of the position and orientation of the antirotational mechanism of an implant to the working cast is particularly important to achieve optimal fit of the final restoration. This study evaluated and compared the accuracy of metal and plastic impression copings for use in a full-arch mandibular edentulous simulation with four implants. Materials and Methods Metal and plastic impression transfer copings for two implant systems, Nobel Biocare Replace and Straumann SynOcta (R), were assessed on a laboratory model to simulate clinical practice. The accuracy of producing stone casts using these plastic and metal impression transfer copings was measured against a standard prosthetic framework consisting of a cast gold bar. A total of 20 casts from the four combinations were obtained. The fit of the framework on the cast was tested by a noncontact surface profilometer, the Proscan 3D 2000 A, using the one-screw test. The effects of implant/system and impression/coping material on gap measurements were analyzed using repeated measures ANOVA. Results The findings of this in vitro study were as follows: plastic copings demonstrated significantly larger average gaps than metal for Straumann (p = 0.001). Plastic and metal copings were not significantly different for Nobel (p = 0.302). Nobel had significantly larger average gaps than Straumann for metal copings (p = 0.003). Nobel had marginally smaller average gaps than Straumann (p = 0.096) for plastic copings. The system-by-screw location interaction was significant as well (p < 0.001), indicating significant differences among the four screw locations, but the location differences were not the same for the two systems. A rank transformation of the data was necessary due to the nonnormal distribution of the gap measurements. No adjustments were made for multiple comparisons. Conclusions The metal impression copings were more accurate than plastic copings when using the Straumann system, and there was no difference between metal and plastic copings for the Nobel Replace system. The system-by-screw location was not conclusive, showing no correlation within each system
引用
收藏
页码:367 / 376
页数:10
相关论文
共 50 条
  • [31] Comparison of the Accuracy of Plastic and Metal Stock Trays for Implant Impressions
    Del'Acqua, Marcelo Antonialli
    de Avila, Erica Dorigatti
    Chagas Amaral, Angela Libia
    Pereira Pinelli, Ligia Antunes
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 544 - 550
  • [32] Effects of Implant Angulation, Material Selection, and Impression Technique on Impression Accuracy: A Preliminary Laboratory Study
    Rutkunas, Vygandas
    Sveikata, Kestutis
    Savickas, Raimondas
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (05) : 512 - 515
  • [33] A COMPARATIVE-ANALYSIS OF THE ACCURACY OF IMPLANT TRANSFER TECHNIQUES
    HSU, CC
    MILLSTEIN, PL
    STEIN, RS
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06): : 588 - 593
  • [34] A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques (vol 28, pg 410, 2020)
    Alikhasi, Marzieh
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (03): : 277 - 277
  • [35] Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
    Papaspyridakos, Panos
    Lal, Kunal
    White, George Shelby
    Weber, Hans-Peter
    Gallucci, German O.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1267 - 1272
  • [36] Comparative analysis of different implant impression techniques: An In vitro study
    Agnihotri, Radhika R.
    Naik, Saloni
    Vaishnav, Kalpesh
    Shah, Dipti S.
    Joshi, Ravi
    Bhatt, Miloni
    ADVANCES IN HUMAN BIOLOGY, 2023, 13 (05) : 44 - 51
  • [37] Cast metal sprue as an alternative to dental floss for splinting open tray impression copings for complete-arch implant impressions
    Gaikwad, Amit M.
    Joshi, Amruta A.
    Nadgere, Jyoti B.
    Kokuyo, Camlin
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 816 - 818
  • [38] A comparative study of marginal fit of copings prepared with various techniques on different implant abutments
    Koc, Esra
    Ongul, Deger
    Sermet, Bulent
    DENTAL MATERIALS JOURNAL, 2016, 35 (03) : 447 - 453
  • [39] A COMPARATIVE-ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN-GAUGE
    HAN, ET
    KIM, YS
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 995 - 995
  • [40] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 149 - 158