A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations

被引:15
|
作者
Fernandez, Monica A. [1 ]
de Mendoza, Carmen Y. Paez [2 ]
Platt, Jeffrey A. [3 ]
Levon, John A. [4 ]
Hovijitra, Suteera T. [2 ]
Nimmo, Arthur [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Restorat Dent Sci, Div Prosthodont, Gainesville, FL 32610 USA
[2] Indiana Univ, Sch Dent, Dept Restorat Dent, Indianapolis, IN USA
[3] Indiana Univ, Sch Dent, Indianapolis, IN USA
[4] Indiana Univ, Sch Dent, Adv Educ Program Prosthodont, Indianapolis, IN USA
关键词
Implant; impressions; jig; gap; screw test; prosthetic framework; misfit; FIXED PARTIAL DENTURES; MASTER CAST ACCURACY; OSSEOINTEGRATED IMPLANTS; GYPSUM CASTS; PROSTHODONTICS; REPLACEMENT; STONE; DIES;
D O I
10.1111/jopr.12015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A precise transfer of the position and orientation of the antirotational mechanism of an implant to the working cast is particularly important to achieve optimal fit of the final restoration. This study evaluated and compared the accuracy of metal and plastic impression copings for use in a full-arch mandibular edentulous simulation with four implants. Materials and Methods Metal and plastic impression transfer copings for two implant systems, Nobel Biocare Replace and Straumann SynOcta (R), were assessed on a laboratory model to simulate clinical practice. The accuracy of producing stone casts using these plastic and metal impression transfer copings was measured against a standard prosthetic framework consisting of a cast gold bar. A total of 20 casts from the four combinations were obtained. The fit of the framework on the cast was tested by a noncontact surface profilometer, the Proscan 3D 2000 A, using the one-screw test. The effects of implant/system and impression/coping material on gap measurements were analyzed using repeated measures ANOVA. Results The findings of this in vitro study were as follows: plastic copings demonstrated significantly larger average gaps than metal for Straumann (p = 0.001). Plastic and metal copings were not significantly different for Nobel (p = 0.302). Nobel had significantly larger average gaps than Straumann for metal copings (p = 0.003). Nobel had marginally smaller average gaps than Straumann (p = 0.096) for plastic copings. The system-by-screw location interaction was significant as well (p < 0.001), indicating significant differences among the four screw locations, but the location differences were not the same for the two systems. A rank transformation of the data was necessary due to the nonnormal distribution of the gap measurements. No adjustments were made for multiple comparisons. Conclusions The metal impression copings were more accurate than plastic copings when using the Straumann system, and there was no difference between metal and plastic copings for the Nobel Replace system. The system-by-screw location was not conclusive, showing no correlation within each system
引用
收藏
页码:367 / 376
页数:10
相关论文
共 50 条
  • [1] Three-Dimensional Accuracy of Plastic Transfer Impression Copings for Three Implant Systems
    Teo, Juin Wei
    Tan, Keson B.
    Nicholls, Jack I.
    Wong, Keng Mun
    Uy, Joanne
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 577 - 584
  • [2] Use of provisional restorations as implant impression copings
    Tsai, Bi-Yuan
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 395 - 396
  • [3] Effect of Multiple Use of Impression Copings on the Accuracy of Implant Transfer
    Alikhasi, Marzieh
    Bassir, Seyed Hossein
    Naini, Roshanak Baghai
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 408 - 414
  • [4] Three-dimensional accuracy of innovative implant-level impression techniques with plastic snap-on impression copings
    Asli, Hamid Neshandar
    Hemmati, Yasamin Babaee
    Falahchai, Mehran
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 351 - 357
  • [5] Effect of Multiple Use of Impression Copings and Scanbodies on Implant Cast Accuracy
    Sawyers, Jordan
    Baig, Mirza Rustum
    ElMasoud, Bilal
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 891 - 898
  • [6] A STUDY ON THE ACCURACY OF MASTER CASTS BY THE TYPES OF IMPRESSION COPINGS
    KIM, YJ
    CHO, LH
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 996 - 996
  • [7] ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS
    Kwon, Joo-Hyun
    Son, Yong-Ha
    Han, Chong-Hyun
    Kim, Sunjai
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (06): : 367 - 373
  • [8] The Influence of Impression Material on the Accuracy of the Master Cast in Implant Restorations
    Stefos, Spyridon
    Kourtis, Stefanos
    Sarafianou, Aspasia
    Zoidis, Panagiotis
    OPEN DENTISTRY JOURNAL, 2018, 12 : 1123 - 1136
  • [9] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [10] In vitro comparative study between complete arch conventional implant impressions and digital implant scans with scannable pick-up impression copings
    Conejo, Julian
    Yoo, Thomas H.
    Atria, Pablo J.
    Fraiman, Howard
    Blatz, Markus B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 475e1 - 475e7