Optical Performance of a Trifocal IOL and a Novel Extended Depth of Focus IOL Combined With Different Corneal Profiles

被引:17
|
作者
Ruiz-Alcocer, Javier [1 ]
Lorente-Velazquez, Amalia [1 ]
Luis Hernandez-Verdejo, Jose [1 ]
De Gracia, Pablo [2 ]
Madrid-Costa, David [1 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Madrid 28037, Spain
[2] Midwestern Univ, Chicago Coll Optometry, Downers Grove, IL 60515 USA
关键词
MODULATION TRANSFER-FUNCTION; MULTIFOCAL INTRAOCULAR LENSES; BENCH PERFORMANCE; VISUAL FUNCTION; PUPIL SIZE; QUALITY; ABERRATIONS; SURGERY;
D O I
10.3928/1081597X-20200519-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the effect of prior myopic ablations on the optical. performance of a trifocal diffractive intraocular tens (IOL) and a novel extended depth of focus (EDOF) diffractive design. METHODS: The novel XACT Mono-EDOF ME4 diffractive IOL (Santen Pharmaceutical) and the trifocal diffractive FineVision IOL (PhysIOL) were analyzed standing atone and combined with a simulated myopic corneal ablation. The optical quality of the IOLs in both situations was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves and the MTF at three different focal points (+0.50, 0.00, and -0.50 diopters [D]) were recorded. RESULTS: The through-focus MTF curves showed three differentiated peaks for the trifocal IOL and two overlapped peaks for the EDOF IOL. The presence of simulated myopic corneal ablations induces a -0.50 D shift on the overall through-focus curves and softens the multifocal properties of both tenses by decreasing the variations through focus of the MTF. For the analysis of the tenses standing atone, the highest MTF values were obtained for an object vergence of 0.00 D. For a simulated myopic corneal ablation, both IOLs showed better optical quality results at -0.50 D. CONCLUSIONS: The trifocal IOL provides better optical quality at far and near distances when analyzed atone. The EDOF IOL optical properties are more stable when a myopic ablation is introduced. Preoperative calculations of both lenses should consider that prior myopic corneal ablations induce a -0.50 D shift on their far peak quality.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [41] Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
    Richard N. McNeely
    Salissou Moutari
    Stephen Stewart
    Jonathan E. Moore
    International Ophthalmology, 2021, 41 : 3985 - 3998
  • [42] Prospective Evaluation of Clinical and Patient-Reported Outcomes Following Contralateral Implantation of an Extended Depth of Focus (EDOF) and Hybrid EDOF-Multifocal IOL
    Waring, George O.
    van den Berg, Arthur B.
    van den Berg, Roberta M.
    Rocha, Karolinne M.
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (10) : e699 - e705
  • [43] Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
    McNeely, Richard N.
    Moutari, Salissou
    Stewart, Stephen
    Moore, Jonathan E.
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (12) : 3985 - 3998
  • [44] The Vivity Extended Range of Vision IOL vs the PanOptix Trifocal, ReStor 2.5 Active Focus and ReStor 3.0 Multifocal Lenses: A Comparison of Patient Satisfaction, Visual Disturbances, and Spectacle Independence
    Hovanesian, John A.
    Jones, Michael
    Allen, Quentin
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 145 - 152
  • [45] The PanOptix Trifocal IOL vs the ReSTOR 2.5 Active Focus and ReSTOR 3.0-Add Multifocal Lenses: A Study of Patient Satisfaction, Visual Disturbances, and Uncorrected Visual Performance
    Hovanesian, John A.
    Jones, Michael
    Allen, Quentin
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 983 - 990
  • [46] Depth of Focus Through Different Intraocular Lenses in Patients With Different Corneal Profiles Using Adaptive Optics Visual Simulation
    Ruiz-Alcocer, Javier
    Perez-Vives, Cari
    Madrid-Costa, David
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (06) : 406 - U42
  • [47] Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens
    Alarcon, Aixa
    Carrasco, Antonio del Aguila
    Gounou, Franck
    Weeber, Henk
    Canovas, Carmen
    Piers, Patricia
    EYE, 2024, 38 (SUPPL 1) : 4 - 8
  • [48] Visual performance with an extended depth of focus contact lens for myopia control and corneal topography in assessing lens centration
    Rizzo, G. C.
    Borghesi, A.
    Di Vizio, A.
    Zeri, F.
    Ponzini, E.
    Tavazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2023, 46 (05):
  • [49] Short-Term Visual Performance of Novel Extended Depth-of-Focus Contact Lenses
    Tilia, Daniel
    Bakaraju, Ravi C.
    Chung, Jiyoon
    Sha, Jennifer
    Delaney, Shona
    Munro, Anna
    Thomas, Varghese
    Ehrmann, Klaus
    Holden, Brien A.
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (04) : 435 - 444
  • [50] Clinical outcomes and optical performance of a new segmental refractive extended depth-of-focus intraocular lens
    Amaro, David Rua
    Bertelmann, Eckart
    von Sonnleithner, Christoph
    BMC OPHTHALMOLOGY, 2024, 24 (01)