Optical Performance of a Trifocal IOL and a Novel Extended Depth of Focus IOL Combined With Different Corneal Profiles

被引:17
|
作者
Ruiz-Alcocer, Javier [1 ]
Lorente-Velazquez, Amalia [1 ]
Luis Hernandez-Verdejo, Jose [1 ]
De Gracia, Pablo [2 ]
Madrid-Costa, David [1 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Madrid 28037, Spain
[2] Midwestern Univ, Chicago Coll Optometry, Downers Grove, IL 60515 USA
关键词
MODULATION TRANSFER-FUNCTION; MULTIFOCAL INTRAOCULAR LENSES; BENCH PERFORMANCE; VISUAL FUNCTION; PUPIL SIZE; QUALITY; ABERRATIONS; SURGERY;
D O I
10.3928/1081597X-20200519-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the effect of prior myopic ablations on the optical. performance of a trifocal diffractive intraocular tens (IOL) and a novel extended depth of focus (EDOF) diffractive design. METHODS: The novel XACT Mono-EDOF ME4 diffractive IOL (Santen Pharmaceutical) and the trifocal diffractive FineVision IOL (PhysIOL) were analyzed standing atone and combined with a simulated myopic corneal ablation. The optical quality of the IOLs in both situations was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves and the MTF at three different focal points (+0.50, 0.00, and -0.50 diopters [D]) were recorded. RESULTS: The through-focus MTF curves showed three differentiated peaks for the trifocal IOL and two overlapped peaks for the EDOF IOL. The presence of simulated myopic corneal ablations induces a -0.50 D shift on the overall through-focus curves and softens the multifocal properties of both tenses by decreasing the variations through focus of the MTF. For the analysis of the tenses standing atone, the highest MTF values were obtained for an object vergence of 0.00 D. For a simulated myopic corneal ablation, both IOLs showed better optical quality results at -0.50 D. CONCLUSIONS: The trifocal IOL provides better optical quality at far and near distances when analyzed atone. The EDOF IOL optical properties are more stable when a myopic ablation is introduced. Preoperative calculations of both lenses should consider that prior myopic corneal ablations induce a -0.50 D shift on their far peak quality.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [21] The accuracy of the trifocal IOL calculation using equivalent K-readings and total corneal power in different zones
    Sergey Viktorovich Shukhaev
    Evgenii Pustozerov
    Ernest Vitalievich Boiko
    Olga Valerievna Kirillova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 495 - 504
  • [22] Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles
    Juan J. Miret
    Vicente J. Camps
    Celia García
    Maria T. Caballero
    Juan M. Gonzalez-Leal
    Scientific Reports, 12
  • [23] Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles
    Miret, Juan J.
    Camps, Vicente J.
    Garcia, Celia
    Caballero, Maria T.
    Gonzalez-Leal, Juan M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [24] The accuracy of the trifocal IOL calculation using equivalent K-readings and total corneal power in different zones
    Shukhaev, Sergey Viktorovich
    Pustozerov, Evgenii
    Boiko, Ernest Vitalievich
    Kirillova, Olga Valerievna
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (02) : 495 - 504
  • [25] Clinical outcomes of a randomized controlled trial comparing two presbyopia correcting IOL designs: Symfony extended depth of focus IOL vs AT LISA tri(focal) 839MP IOL
    Saelens, I. E. Y.
    Webers, V.
    Bauer, N. J. C.
    Creten, O. J. M.
    Nuijts, R. M. M. A.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 35 - 35
  • [26] New set of complementary extended-depth-of-focus IOL: comparison with the state-of-the-art
    Castignoles, Fannie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [27] Prediction accuracy of IOL calculation formulas using the ASCRS online calculator for a diffractive extended depth-of-focus IOL after myopic laser in situ keratomileusis
    Lwowski, Christoph
    Pawlowicz, Katarzyna
    Hinzelmann, Lisa
    Adas, Mahmoud
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (09): : 1240 - 1246
  • [28] Clinical Outcomes of a Non-Diffractive Extended Depth-of-Focus IOL in Eyes with Mild Glaucoma
    Ferguson, Tanner J.
    Wilson, Caroline W.
    Shafer, Brian M.
    Berdahl, John P.
    Terveen, Daniel C.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 861 - 868
  • [29] Clinical Evaluation of Violet Light Filtration and High-Resolution Lathing on a Diffractive Extended Depth of Focus IOL
    Chang, Daniel H.
    Kao, Andrew A.
    Huggins, Laura K.
    Albert, Jacqueline N.
    Whinery, Jacqueline N.
    Camirand, Brittany M.
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (12) : 3135 - 3147
  • [30] Clinical evaluation of tolerance to residual refractive errors following implantation with a refractive extended depth of focus (EDF) IOL
    Vilupuru, Srividhya
    Alarcon, Aixa
    Tsai, Linda
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)