Optical Performance of a Trifocal IOL and a Novel Extended Depth of Focus IOL Combined With Different Corneal Profiles

被引:17
|
作者
Ruiz-Alcocer, Javier [1 ]
Lorente-Velazquez, Amalia [1 ]
Luis Hernandez-Verdejo, Jose [1 ]
De Gracia, Pablo [2 ]
Madrid-Costa, David [1 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Madrid 28037, Spain
[2] Midwestern Univ, Chicago Coll Optometry, Downers Grove, IL 60515 USA
关键词
MODULATION TRANSFER-FUNCTION; MULTIFOCAL INTRAOCULAR LENSES; BENCH PERFORMANCE; VISUAL FUNCTION; PUPIL SIZE; QUALITY; ABERRATIONS; SURGERY;
D O I
10.3928/1081597X-20200519-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the effect of prior myopic ablations on the optical. performance of a trifocal diffractive intraocular tens (IOL) and a novel extended depth of focus (EDOF) diffractive design. METHODS: The novel XACT Mono-EDOF ME4 diffractive IOL (Santen Pharmaceutical) and the trifocal diffractive FineVision IOL (PhysIOL) were analyzed standing atone and combined with a simulated myopic corneal ablation. The optical quality of the IOLs in both situations was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves and the MTF at three different focal points (+0.50, 0.00, and -0.50 diopters [D]) were recorded. RESULTS: The through-focus MTF curves showed three differentiated peaks for the trifocal IOL and two overlapped peaks for the EDOF IOL. The presence of simulated myopic corneal ablations induces a -0.50 D shift on the overall through-focus curves and softens the multifocal properties of both tenses by decreasing the variations through focus of the MTF. For the analysis of the tenses standing atone, the highest MTF values were obtained for an object vergence of 0.00 D. For a simulated myopic corneal ablation, both IOLs showed better optical quality results at -0.50 D. CONCLUSIONS: The trifocal IOL provides better optical quality at far and near distances when analyzed atone. The EDOF IOL optical properties are more stable when a myopic ablation is introduced. Preoperative calculations of both lenses should consider that prior myopic corneal ablations induce a -0.50 D shift on their far peak quality.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [31] Clinically Relevant Optical Properties of Bifocal, Trifocal, and Extended Depth of Focus Intraocular Lenses
    Gatinel, Damien
    Loicq, Jerome
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) : 273 - +
  • [32] Visual Outcomes and Subjective Experience After Combined Implantation of Extended Depth of Focus and Trifocal IOLs
    McNeely, Richard N.
    Moutari, Salissou
    Palme, Christoph
    Moore, Jonathan E.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (05) : 326 - +
  • [33] Preoperative Treatment of Meibomian Gland Dysfunction with a Vectored Thermal Pulsation System Prior to Extended Depth of Focus IOL Implantation
    Cynthia Matossian
    Daniel H. Chang
    Jeffrey Whitman
    Thomas E. Clinch
    Jerry Hu
    Leilei Ji
    David Murakami
    Ying Wang
    Caroline A. Blackie
    Ophthalmology and Therapy, 2023, 12 : 2427 - 2439
  • [34] Preoperative Treatment of Meibomian Gland Dysfunction with a Vectored Thermal Pulsation System Prior to Extended Depth of Focus IOL Implantation
    Matossian, Cynthia
    Chang, Daniel H.
    Whitman, Jeffrey
    Clinch, Thomas E.
    Hu, Jerry
    Ji, Leilei
    Murakami, David
    Wang, Ying
    Blackie, Caroline A.
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (05) : 2427 - 2439
  • [35] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [36] Accuracy of Nine Formulas to Calculate the Powers of an Extended Depth-of-Focus IOL Using Two SS-OCT Biometers
    Jeon, Sohee
    Taroni, Leonardo
    Lupardi, Enrico
    Hoffer, Kenneth J.
    Fontana, Luigi
    Schiano-Lomoriello, Domenico
    Kwon, Hyunggoo
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (03) : 158 - +
  • [37] Clinical Outcomes after Bilateral Implantation of a Wavefront-Shaping Extended Depth of Focus (EDOF) IOL with Mini-Monovision
    Won, Yeo Kyoung
    Choi, Sung Ho
    Chung, Tae-Young
    Lim, Dong Hui
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [38] Optical and predicted visual performance of multifocal and extended depth of focus designs
    State, Mihai
    Canovas, Carmen
    Faria-Ribeiro, Miguel
    Perez, Guillermo
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [39] The Postoperative Visual and Refractive Outcomes of Trifocal and Extended Depth-of-Focus Intraocular Lenses in Patients with Different Biometric Characteristics
    Lee, Chia-Yi
    Chen, Hung-Chi
    Lian, Ie-Bin
    Huang, Jing-Yang
    Yang, Shun-Fa
    Chang, Chao-Kai
    DIAGNOSTICS, 2024, 14 (16)
  • [40] Optical performance of different refractive technologies that increase the depth of focus
    Alarcon, Aixa
    Koopman, Bram
    Faria-Ribeiro, Miguel
    Canovas, Carmen
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)