We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si[1 1 1] crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) instability of the shape of the beam's horizontal profile. Compared with that earlier monochromator, the bent Laue-Laue device tested at 42 and 108 keV showed about a 10-fold larger beam flux, about 5 times better beam stability, 10-fold less harmonic contamination, and a smaller energy bandwidth at certain bending radii. The present work gave us better understanding of the basis for the beam-smiling effect in bent-crystal monochromators, and allowed us to refine the theoretical method of estimating the beam-harmonic contamination in bent-crystal monochromators. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:528 / 550
页数:23
相关论文
共 50 条
  • [31] Cryogenically cooled bent double-Laue monochromator for high-energy undulator X-rays (50-200 keV)
    Shastri, SD
    Fezzaa, K
    Mashayekhi, A
    Lee, WK
    Fernandez, PB
    Lee, PL
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 317 - 322
  • [32] Effects of vegetation restoration on soil aggregate microstructure quantified with synchrotron-based micro-computed tomography
    Zhou, H.
    Peng, X.
    Peth, S.
    Xiao, T. Q.
    SOIL & TILLAGE RESEARCH, 2012, 124 : 17 - 23
  • [33] A laboratory based system for Laue micro x-ray diffraction
    Lynch, P. A.
    Stevenson, A. W.
    Liang, D.
    Parry, D.
    Wilkins, S.
    Tamura, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (02):
  • [34] Synchrotron-based imaging and tomography with hard X-rays
    Rau, C.
    Crecea, V.
    Liu, W.
    Richter, C.-P.
    Peterson, K. M.
    Jemian, P. R.
    Neuhaeusler, U.
    Schneider, G.
    Yu, X.
    Braun, P. V.
    Chiang, T.-C.
    Robinson, I. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 850 - 854
  • [35] Efficient and Precise Phenotyping of Murine Fetal Hearts by Means of Synchrotron-Based PhaseContrast Micro-Computed Tomography
    Peruzzi, Niccolo
    Gawlik, Kinga I.
    Mead, Timothy
    Dreier, Till
    Lampei, Elna
    Romell, Jenny
    Apte, Suneel S.
    Bech, Martin
    Bonnin, Anne
    Tran-Lundmark, Karin
    CIRCULATION, 2023, 148
  • [36] Quantifying influence of tillage practices on soil aggregate microstructure using synchrotron-based micro-computed tomography
    Gao, Yan
    Liang, Aizhen
    Fan, Ruqin
    Guo, Yafei
    Zhang, Yan
    McLaughlin, Neil
    Chen, Xuewen
    Zheng, Haifeng
    Wu, Donghui
    SOIL USE AND MANAGEMENT, 2022, 38 (01) : 850 - 860
  • [37] Synchrotron-based micro computed tomography investigation of the implant-abutment fatigue-induced microgap changes
    Bagegni, Aimen
    Zabler, Simon
    Nelson, Katja
    Rack, Alexander
    Spies, Benedikt C.
    Vach, Kirstin
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 116
  • [38] Preparation and measurement of an x-ray Laue-type monochromator based on a WSi2/Si multilayer
    Yue, Shuaipeng
    Hou, Qingyan
    Ji, Bin
    Zhou, Liang
    Li, Ming
    Liu, Peng
    Chang, Guangcai
    APPLIED OPTICS, 2024, 63 (12) : 3260 - 3264
  • [39] Analysis of the full stress tensor in a micropillar: Ability of and difficulties arising during synchrotron based μLaue diffraction
    Davydok, Anton
    Jaya, Balila Nagamani
    Robach, Odile
    Ulrich, Olivier
    Micha, Jean-Sebastien
    Kirchlechner, Christoph
    MATERIALS & DESIGN, 2016, 108 : 68 - 75
  • [40] Clinical commissioning a synchrotron-based proton therapy system
    Azcona, J. D.
    Aguilar, B.
    Irazola, L.
    Vinals, A.
    Cabello, P.
    Zucca, D.
    Perales, A.
    Polo, R.
    Delgado, J. M.
    Burguete, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1422 - S1423