A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

被引:13
|
作者
Ren, B [1 ]
Dilmanian, FA
Chapman, LD
Ivanov, I
Wu, XY
Zhong, Z
Huang, X
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
[2] IIT, Ctr Synchrotron Radiat Res & Instrumentat, Chicago, IL 60616 USA
[3] Brookhaven Natl Lab, Natl Synchrotron Light Source Dept, Upton, NY 11973 USA
关键词
bent crystal monochromator; beam smiling; harmonics rejection; Laue spot; CT;
D O I
10.1016/S0168-9002(99)00056-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si[1 1 1] crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) instability of the shape of the beam's horizontal profile. Compared with that earlier monochromator, the bent Laue-Laue device tested at 42 and 108 keV showed about a 10-fold larger beam flux, about 5 times better beam stability, 10-fold less harmonic contamination, and a smaller energy bandwidth at certain bending radii. The present work gave us better understanding of the basis for the beam-smiling effect in bent-crystal monochromators, and allowed us to refine the theoretical method of estimating the beam-harmonic contamination in bent-crystal monochromators. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:528 / 550
页数:23
相关论文
共 50 条
  • [21] A bent Laue analyzer detection system for dilute fluorescence XAFS
    Karanfil, C
    Zhong, Z
    Chapman, LD
    Fischetti, R
    Bunker, GB
    Segre, CU
    Bunker, BA
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 178 - 182
  • [22] Design of a mouse restraint for synchrotron-based computed tomography imaging
    Gagnon, Kenneth B.
    Caine, Sally
    Samadi, Nazanin
    Martinson, Mercedes
    Van der Loop, Melanie
    Alcorn, Jane
    Chapman, L. Dean
    Belev, George
    Nichol, Helen
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1297 - 1300
  • [23] Double Laue-crystal monochromator for an X-ray imaging beamline with synchrotron radiation
    Hu Wen
    Xie Hong-Lan
    Du Guo-Hao
    Xiao Ti-Qiao
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (06): : 597 - 601
  • [24] A vacuum ultraviolet filtering monochromator for synchrotron-based spectroscopy
    Janik, Ireneusz
    Marin, Timothy W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 698 : 44 - 48
  • [25] Simulation of bent Laue crystals for a high-energy X-ray monochromator with heat load consideration
    Wang, Jiayi
    Gao, Lidan
    Li, Ming
    Yang, Yiming
    Li, Yanchun
    Cheng, Hu
    Fan, Longlong
    Wang, Youkang
    Guo, Huilong
    Jia, Quanjie
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2025, 58 : 154 - 167
  • [26] Development of a microarea diffraction system by polychromatic synchrotron radiation with the Laue method
    Ohsumi, Kazumasa
    Hagiya, Kenji
    Uchida, Masaya
    Suda, Noboru
    Miyamoto, Masamichi
    Kitamura, Masao
    Ohmasa, Masaaki
    Review of Scientific Instruments, 1995, 66 (2 pt 2):
  • [27] Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging
    Martinson, Mercedes
    Samadi, Nazanin
    Belev, George
    Bassey, Bassey
    Lewis, Rob
    Aulakh, Gurpreet
    Chapman, Dean
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 479 - 483
  • [28] DEVELOPMENT OF A MICROAREA DIFFRACTION SYSTEM BY POLYCHROMATIC SYNCHROTRON-RADIATION WITH THE LAUE METHOD
    OHSUMI, K
    HAGIYA, K
    UCHIDA, M
    SUDA, N
    MIYAMOTO, M
    KITAMURA, M
    OHMASA, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1448 - 1450
  • [29] Synchrotron-based dynamic computed tomography of tissue motion for regional lung function measurement
    Dubsky, Stephen
    Hooper, Stuart B.
    Siu, Karen K. W.
    Fouras, Andreas
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2012, 9 (74) : 2213 - 2224
  • [30] STRUCTURE REFINEMENT BASED ON INTENSITIES OF LAUE SPOTS OBTAINED BY POLYCHROMATIC SYNCHROTRON RAD.
    Ohsumi, K.
    Osaka, T.
    Hagiya, K.
    Ohmasa, M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 233 - 234