Comparing different methods for estimating radiation dose to the conceptus

被引:8
|
作者
Lopez-Rendon, X. [1 ]
Walgraeve, M. S. [2 ]
Woussen, S. [2 ]
Dedulle, A. [1 ]
Zhang, G. [2 ]
Bosmans, H. [1 ,2 ]
Zanca, F. [1 ,3 ]
机构
[1] Katholieke Univ Leuven, Div Med Phys & Qual Assessment, Dept Imaging & Pathol, Herestr 49,Box 7003, B-3000 Leuven, Belgium
[2] Univ Hosp Leuven, Dept Radiol, Herestr 49, B-3000 Leuven, Belgium
[3] GE Healthcare, Buc, France
关键词
Pregnancy; Dose to the conceptus; Tube current modulation; Commercial software package; Monte Carlo simulations; MONTE-CARLO SIMULATIONS; TUBE CURRENT MODULATION; PREGNANT PATIENTS; MULTIDETECTOR CT; GESTATION; PATIENT; PHANTOM; FETUS; DEPTH;
D O I
10.1007/s00330-016-4389-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare different methods available in the literature for estimating radiation dose to the conceptus (D-conceptus) against a patient-specific Monte Carlo (MC) simulation and a commercial software package (CSP). Eight voxel models from abdominopelvic CT exams of pregnant patients were generated. D-conceptus was calculated with an MC framework including patient-specific longitudinal tube current modulation (TCM). For the same patients, dose to the uterus, D-uterus, was calculated as an alternative for D-conceptus, with a CSP that uses a standard-size, non-pregnant phantom and a generic TCM curve. The percentage error between D-uterus and D-conceptus was studied. Dose to the conceptus and percent error with respect to D-conceptus was also estimated for three methods in the literature. The percentage error ranged from -15.9% to 40.0% when comparing MC to CSP. When comparing the TCM profiles with the generic TCM profile from the CSP, differences were observed due to patient habitus and conceptus position. For the other methods, the percentage error ranged from -30.1% to 13.5% but applicability was limited. Estimating an accurate D-conceptus requires a patient-specific approach that the CSP investigated cannot provide. Available methods in the literature can provide a better estimation if applicable to patient-specific cases. aEuro cent A patient's internal anatomy affects the dose to the conceptus. aEuro cent Conceptus position has an influence on its dose estimation. aEuro cent Patient anatomy and specific TCM must be considered for accurate conceptus dosimetry. aEuro cent D (uterus) to a standard-size phantom should not be used as D (conceptus) .
引用
收藏
页码:851 / 858
页数:8
相关论文
共 50 条
  • [21] Estimating radiation dose from building materials
    Gupta, M.
    Chauhan, R. P.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2011, 9 (03): : 187 - 194
  • [22] Cardiac Radiation Dose Reconstruction in the Study of Late Effects: A Comparison of Different Methods
    Ntentas, G.
    Aznar, M. C.
    Hodgson, D.
    Darby, S. C.
    Ahmed, S.
    Ng, A.
    Cutter, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E635
  • [23] Radiation Dose to the Conceptus from Multidetector CT during Early Gestation: A Method That Allows for Variations in Maternal Body Size and Conceptus Position
    Damilakis, John
    Perisinakis, Kostas
    Tzedakis, Antonis
    Papadakis, Antonios E.
    Karantanas, Apostolos
    RADIOLOGY, 2010, 257 (02) : 483 - 489
  • [24] Cardiac Radiation Dose Reconstruction in the Study of Late Effects: A Comparison of Different Methods
    Ntentas, G.
    Aznar, M. C.
    Hodgson, D. C.
    Howell, R. M.
    Maraldo, M. V.
    Ahmed, S.
    Ng, A.
    Darby, S. C.
    Cutter, D. J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1091 - S1092
  • [25] Conceptus radiation dose assessment from fluoroscopically assisted surgical treatment of hip fractures
    Damilakis, J
    Theocharopoulos, N
    Perisinakis, K
    Papadokostakis, G
    Hadjipavlou, A
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2003, 30 (10) : 2594 - 2601
  • [26] Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study
    Sciahbasi, A.
    Rigattieri, S.
    Sarandrea, A.
    Cera, M.
    Di Russo, C.
    Fedele, S.
    Romano, S.
    Pugliese, F. R.
    Penco, M.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1030 - 1030
  • [27] Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study
    Sciahbasi, Alessandro
    Rigattieri, Stefano
    Sarandrea, Alessandro
    Cera, Maria
    Di Russo, Cristian
    Fedele, Silvio
    Romano, Silvio
    Pugliese, Francesco Rocco
    Penco, Maria
    EUROINTERVENTION, 2017, 12 (18) : E2253 - E2261
  • [28] Comparing methods for estimating seropositivity thresholds in trachoma research
    Bradley, Chris
    Massof, Robert W.
    West, Sheila K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [29] Comparing methods for estimating-premorbid intellectual functioning
    Axelrod, BN
    Vanderploeg, RD
    Schinka, JA
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 1999, 14 (04) : 341 - 346
  • [30] COMPARING RANGE ESTIMATING METHODS FOR CHANGE ORDER NEGOTIATIONS
    SPITTLER, JR
    KNOKE, JR
    PROCEEDINGS OF THE 1991 PMI ANNUAL SEMINAR / SYMPOSIUM : MANAGING FOR QUALITY, 1991, : 209 - 214