Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range

被引:4
|
作者
Gago-Arias, A. [1 ,2 ]
Gonzalez-Castano, D. M. [3 ]
Gomez, F. [2 ,3 ]
Peteiro, E. [4 ]
Lodeiro, C. [4 ]
Pardo-Montero, J. [5 ,6 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Fis, Santiago, Chile
[2] Univ Santiago de Compostela, Fac Fis, Dept Fis Particulas, Santiago De Compostela, Spain
[3] Univ Santiago de Compostela, Radiat Phys Lab, Santiago De Compostela, Spain
[4] Univ Santiago de Compostela, Rede Infraestruct Apoio Invest & Desenvolvemento, Unidade Resonancia Paramagnet Elect, Santiago De Compostela, Spain
[5] Complexo Hosp Univ Santiago de Compostela, Serv Radiofis & Protecc Radiolox, Santiago De Compostela, Spain
[6] Inst Invest Sanitaria IDIS, Grp Imaxe Mol, Santiago De Compostela, Spain
来源
关键词
Spectrometers; Dosimetry concepts and apparatus; ENERGY-DEPENDENCE; ANGULAR RESPONSE; EPR; ACCURACY; STANDARD; AUDIT;
D O I
10.1088/1748-0221/10/08/T08004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Alanine/ESR systems provide an interesting alternative to standard dosimetry systems like solid state or gas ionization chambers for dosimetry in radiotherapy. This is primarily due to the negligible energy dependence, high stability, and the possibility of using small pellets that are especially suitable for the dosimetry of small fields. In order to obtain acceptable dose uncertainties in the radiotherapy dose range, the setup, operational parameters and quantification methods need to be carefully investigated and optimized. In this work we present the development of an alanine/ESR dosimetry system, traced to the secondary standard laboratory of absorbed dose to water at the Radiation Physics Laboratory of the Universidade de Santiago de Compostela (Spain). We focus on the setup, the optimization of the operational parameters of the ESR spectrometer, the quantification of the readout signal and the construction of a calibration curve. The evaluation of the uncertainty budget is also a key component of an alanine/ESR system for radiotherapy dosimetry, and is presented in detail. After the optimization of the procedures, we have achieved a relative uncertainty of 1.7% (k = 2) for an absorbed dose of 10 Gy, decreasing to 0.9% for 50 Gy.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Calibration of EPR spectrometer and measurement of dose from radiation field around linac by alanine dosimetry
    Liang, Renyou
    Xu, Yunhua
    Li, Yuxiong
    Li, Juexin
    Gao, Juncheng
    He Jishu/Nuclear Techniques, 1993, 16 (04): : 254 - 256
  • [42] Absorbed-dose/dose-rate dependence studies for the alanine-EPR dosimetry system
    Desrosiers, M. F.
    Puhl, J. M.
    RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (7-8) : 461 - 463
  • [43] Feasibility study of entrance and exit dose measurements at the contra lateral breast with alanine/electron spin resonance dosimetry in volumetric modulated radiotherapy of breast cancer
    Wagner, Daniela M.
    Huettenrauch, Petra
    Anton, Mathias
    von Voigts-Rhetz, Philip
    Zink, Klemens
    Wolff, Hendrik A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13): : 5462 - 5472
  • [44] Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements
    Boudou, C.
    Tropres, I.
    Rousseau, J.
    Lamalle, L.
    Adam, J. F.
    Esteve, F.
    Elleaume, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4881 - 4892
  • [45] Dose verification and calibration of the Cyberknife® by EPR/alanine dosimetry
    Garcia, Tristan
    Lacornerie, Thomas
    Popoff, Romain
    Lourenco, Valerie
    Bordy, Jean-Marc
    RADIATION MEASUREMENTS, 2011, 46 (09) : 952 - 957
  • [46] Validation of the National Research Council alanine dosimetry system for linac electron beam measurements
    Surensoy, Rodi
    Muir, Bryan
    MEDICAL PHYSICS, 2021, 48 (08) : 4689 - 4689
  • [47] ESR ALANINE DOSIMETRY OF HIGH-ENERGY ELECTRONS IN RADIOTHERAPY
    CHU, S
    WIESER, A
    FEIST, H
    REGULLA, DF
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (10-12) : 993 - 996
  • [48] Use of alanine for dosimetry intercomparisons among Italian Radiotherapy Centers
    De Angelis, C
    De Coste, V
    Fattibene, P
    Onori, S
    Petetti, E
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (02) : 261 - 265
  • [49] ESR/alanine dosimetry of high-energy electrons in radiotherapy
    Chu, S.
    Wieser, A.
    Feist, H.
    Regulla, D.F.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1989, 40 (10-12): : 993 - 996
  • [50] Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece
    Wagner, Daniela
    Anton, Mathias
    Vorwerk, Hilke
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05): : 1373 - 1383