Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range

被引:4
|
作者
Gago-Arias, A. [1 ,2 ]
Gonzalez-Castano, D. M. [3 ]
Gomez, F. [2 ,3 ]
Peteiro, E. [4 ]
Lodeiro, C. [4 ]
Pardo-Montero, J. [5 ,6 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Fis, Santiago, Chile
[2] Univ Santiago de Compostela, Fac Fis, Dept Fis Particulas, Santiago De Compostela, Spain
[3] Univ Santiago de Compostela, Radiat Phys Lab, Santiago De Compostela, Spain
[4] Univ Santiago de Compostela, Rede Infraestruct Apoio Invest & Desenvolvemento, Unidade Resonancia Paramagnet Elect, Santiago De Compostela, Spain
[5] Complexo Hosp Univ Santiago de Compostela, Serv Radiofis & Protecc Radiolox, Santiago De Compostela, Spain
[6] Inst Invest Sanitaria IDIS, Grp Imaxe Mol, Santiago De Compostela, Spain
来源
关键词
Spectrometers; Dosimetry concepts and apparatus; ENERGY-DEPENDENCE; ANGULAR RESPONSE; EPR; ACCURACY; STANDARD; AUDIT;
D O I
10.1088/1748-0221/10/08/T08004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Alanine/ESR systems provide an interesting alternative to standard dosimetry systems like solid state or gas ionization chambers for dosimetry in radiotherapy. This is primarily due to the negligible energy dependence, high stability, and the possibility of using small pellets that are especially suitable for the dosimetry of small fields. In order to obtain acceptable dose uncertainties in the radiotherapy dose range, the setup, operational parameters and quantification methods need to be carefully investigated and optimized. In this work we present the development of an alanine/ESR dosimetry system, traced to the secondary standard laboratory of absorbed dose to water at the Radiation Physics Laboratory of the Universidade de Santiago de Compostela (Spain). We focus on the setup, the optimization of the operational parameters of the ESR spectrometer, the quantification of the readout signal and the construction of a calibration curve. The evaluation of the uncertainty budget is also a key component of an alanine/ESR system for radiotherapy dosimetry, and is presented in detail. After the optimization of the procedures, we have achieved a relative uncertainty of 1.7% (k = 2) for an absorbed dose of 10 Gy, decreasing to 0.9% for 50 Gy.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] One year of experience with alanine dosimetry in radiotherapy
    Schaeken, B
    Scalliet, P
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1177 - 1182
  • [22] DOSIMETRY SYSTEM USING THERMOLUMINESCENCE DOSIMETRY (TLD) FOR CLINICAL MEASUREMENTS DURING RADIOTHERAPY
    LINDSKOU.B
    BENGTSSO.BE
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 670 - &
  • [23] Implementation of alanine/EPR as transfer dosimetry system in a radiotherapy audit programme in Belgium
    Schaeken, B.
    Cuypers, R.
    Lelie, S.
    Schroeyers, W.
    Schreurs, S.
    Janssens, H.
    Verellen, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 (01) : 94 - 96
  • [24] DOSIMETRY FOR RADIATION PROCESSING OF WIRE INSULATIONS BY USING THE ALANINE ESR SYSTEM
    JANOVSKY, I
    KLIMAN, N
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1990, 140 (01): : 187 - 194
  • [25] Development of an alanine-based audit dosimetry system for Canada
    Mansour, Iymad
    McEwen, Malcolm
    MEDICAL PHYSICS, 2017, 44 (08) : 4390 - 4390
  • [26] In vivo dose evaluation during gynaecological radiotherapy using l-alanine/ESR dosimetry
    Rech, Amanda Burg
    Barbi, Gustavo Lazzaro
    Almeida Ventura, Luiz Henrique
    Guimaraes, Flavio Silva
    Oliveira, Harley Francisco
    Baffa, Oswaldo
    RADIATION PROTECTION DOSIMETRY, 2014, 159 (1-4) : 194 - 198
  • [27] Dosimetry measurements in radiotherapy beams using a commercial OSL system
    Cygler, J.
    Viamonte, M. A.
    Da Rosa, L. A. R.
    Buckley, L. A.
    Cherpak, A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S244 - S244
  • [28] Evaluation of a commercial OSL system for dosimetry measurements in radiotherapy beams
    Viamonte Marin, A.
    Ribeiro Da Rosa, L.
    Buckley, L.
    Cherpak, A.
    Cygler, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2448 - 2448
  • [29] ALANINE ESR DOSIMETRY - ASSESSMENT OF DOSE EVALUATION
    SCHNEIDER, CCJ
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1990, 58 (05) : 915 - 915
  • [30] Effects of dose fractionation on the response of alanine dosimetry
    Lundahl, Brad
    Logar, John
    Desrosiers, Marc
    Puhl, James
    RADIATION PHYSICS AND CHEMISTRY, 2014, 105 : 94 - 97