Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range

被引:4
|
作者
Gago-Arias, A. [1 ,2 ]
Gonzalez-Castano, D. M. [3 ]
Gomez, F. [2 ,3 ]
Peteiro, E. [4 ]
Lodeiro, C. [4 ]
Pardo-Montero, J. [5 ,6 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Fis, Santiago, Chile
[2] Univ Santiago de Compostela, Fac Fis, Dept Fis Particulas, Santiago De Compostela, Spain
[3] Univ Santiago de Compostela, Radiat Phys Lab, Santiago De Compostela, Spain
[4] Univ Santiago de Compostela, Rede Infraestruct Apoio Invest & Desenvolvemento, Unidade Resonancia Paramagnet Elect, Santiago De Compostela, Spain
[5] Complexo Hosp Univ Santiago de Compostela, Serv Radiofis & Protecc Radiolox, Santiago De Compostela, Spain
[6] Inst Invest Sanitaria IDIS, Grp Imaxe Mol, Santiago De Compostela, Spain
来源
关键词
Spectrometers; Dosimetry concepts and apparatus; ENERGY-DEPENDENCE; ANGULAR RESPONSE; EPR; ACCURACY; STANDARD; AUDIT;
D O I
10.1088/1748-0221/10/08/T08004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Alanine/ESR systems provide an interesting alternative to standard dosimetry systems like solid state or gas ionization chambers for dosimetry in radiotherapy. This is primarily due to the negligible energy dependence, high stability, and the possibility of using small pellets that are especially suitable for the dosimetry of small fields. In order to obtain acceptable dose uncertainties in the radiotherapy dose range, the setup, operational parameters and quantification methods need to be carefully investigated and optimized. In this work we present the development of an alanine/ESR dosimetry system, traced to the secondary standard laboratory of absorbed dose to water at the Radiation Physics Laboratory of the Universidade de Santiago de Compostela (Spain). We focus on the setup, the optimization of the operational parameters of the ESR spectrometer, the quantification of the readout signal and the construction of a calibration curve. The evaluation of the uncertainty budget is also a key component of an alanine/ESR system for radiotherapy dosimetry, and is presented in detail. After the optimization of the procedures, we have achieved a relative uncertainty of 1.7% (k = 2) for an absorbed dose of 10 Gy, decreasing to 0.9% for 50 Gy.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] RADIATION DOSIMETRY OF INTRALYMPHATIC RADIOTHERAPY
    OWEN, GM
    CROSBY, DL
    JONESWIL.W
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1969, 62 (06): : 545 - &
  • [32] RADIATION DOSIMETRY OF INTRALYMPHATIC RADIOTHERAPY
    OWEN, GM
    CROSBY, DL
    JONESWIL.W
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 173 - &
  • [33] Numerical signal treatment for optimized alanine/ESR dosimetry in the therapy-level dose range
    Ruckerbauer, F
    Sprunck, M
    Regulla, DF
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1263 - 1268
  • [34] An absorbed-dose/dose-rate dependence for the alanine-EPR dosimetry system and its implications in high-dose ionizing radiation metrology
    Desrosiers, M. F.
    Publ, J. M.
    Cooper, S. L.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2008, 113 (02): : 79 - 95
  • [35] Alanine-ESR dosimetry for radiotherapy IAEA experience
    Mehta, K
    Girzikowsky, R
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1189 - 1191
  • [36] Alanine/electron spin resonance dosimetry for FLASH radiotherapy
    Gu, Runqiu
    Wang, Jianlin
    Wang, Pan
    Mao, Xin
    Lin, Binwei
    Tan, Wanchao
    Du, Xiaobo
    Gao, Feng
    Wang, Tingting
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [37] Simple dose verification system for radiotherapy radiation
    Lee, J. H.
    Yeh, C. Y.
    Hsu, S. M.
    Shi, M. Y.
    Chen, W. L.
    Wang, C. F.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 954 - 958
  • [38] Development of instrumental ORAM system for radiation dosimetry
    Cullum, BM
    Mobley, J
    Bogard, JS
    Moscovitch, M
    Vo-Dinh, T
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES II, 1999, 3853 : 376 - 384
  • [39] Application of alanine dosimetry in dose assessment for ocular melanoma patients undergoing proton radiotherapy - preliminary results
    Mierzwinska, Gabriela
    Klodowska, Magdalena
    Michalec, Barbara
    Pedracka, Anna
    Rydygier, Marzena
    Swakon, Jan
    Waligorski, Michael P. R.
    NUKLEONIKA, 2015, 60 (03) : 609 - 613
  • [40] LYOLUMINESCENCE DOSIMETRY FOR RADIOTHERAPY RANGE OF DOSES
    MALLARD, JR
    ANUNUSO, CI
    ETTINGER, KV
    SRIRATH, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 766 - 766