ATCA data acquisition system for gamma-ray spectrometry

被引:30
|
作者
Pereira, R. C. [1 ]
Sousa, J. [1 ]
Fernandes, A. M. [1 ]
Patricio, F. [1 ]
Carvalho, B. [1 ]
Neto, A. [1 ]
Varandas, C. A. F. [1 ]
Gorini, G. [2 ]
Tardocchi, M. [2 ]
Gin, D. [3 ]
Shevelev, A. [3 ]
机构
[1] Univ Tecn Lisboa, IST Ctr Fusao Nucl, Inst Super Tecn, EURATOM Assoc, Lisbon, Portugal
[2] EURATOM ENEA CNR Assoc, Ist Fis Plasma, Milan, Italy
[3] Russian Acad Sci, AF Ioffe Physicotech Inst, St Petersburg 194021, Russia
关键词
data acquisition; gamma-ray spectroscopy; PHA; pulse processing;
D O I
10.1016/j.fusengdes.2007.10.011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The gamma-ray spectrometer JET EP2 (Joint European Torus enhancement project 2) project aims to perform high-resolution gamma spectroscopy at very high count rate (up to few MHz). Traditional analogue electronic has count rate and pulse processing limitations (long dead-time, pile-up challenge). Digital pulse processing (DPP) systems have been shown to have better performance than analogue ones for processing neutrons or/and gamma-ray signals. DPP can synthesize almost any pulse response shape without the signal degradation associated to complex analogue paths. High-speed transient recorders (TR) with auto-trigger functionality are used to digitize and store the detailed shape of pulses. The data acquisition (DAQ) system provides sophisticated analysis/data reduction based on real time algorithms, implemented in field programmable gate arrays (FPGA), for Pulse Height Analysis (PHA) while resolving pulse pile-up of digitized pulses. This paper describes a new DAQ system for real-time pulse analysis. The system is based on the Advanced Telecommunications Computing Architecture (TM) (ATCA (TM)) and contains an ix86-based processor blade with up to 40 GFLOPS and a TR module interconnected through PCI Express (PCIe) links. TR module features: (i) 8 channels of 13 bit resolution with accuracy equal or higher than 11 bit to cope with the expected signal-to-noise ratio (SNR) of the input pulses; (ii) up to 500 MSamples/s sampling rate with the possibility to achieve 1 GSamples/s; and (iii) 2 or 4 GB of local memory. The core of the TR module is two FPGAs able to perform real-time processing algorithms such as PHA and pile-up resolution. This will allow data reduction by a factor of at least 6 and eventually spectra output in real-time. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 50 条
  • [31] AIRBORNE GAMMA-RAY SPECTROMETRY
    DARNLEY, AG
    CANADIAN MINING AND METALLURGICAL BULLETIN, 1970, 63 (694): : 145 - &
  • [32] GAMMA-RAY SCINTILLATION SPECTROMETRY
    COOK, CS
    AMERICAN SCIENTIST, 1957, 45 (03) : 245 - 262
  • [33] AIRBORNE GAMMA-RAY SPECTROMETRY
    DARNLEY, AG
    CANADIAN MINING AND METALLURGICAL BULLETIN, 1969, 62 (683): : 215 - &
  • [34] DATA-ANALYSIS TECHNIQUES FOR GAMMA-RAY SCINTILLATION SPECTROMETRY
    NORDHAGE.R
    SJOBERG, S
    PHYSICA NORVEGICA, 1967, 2 (02): : 129 - +
  • [35] Online gamma-ray spectroscopy acquisition
    Yang, Xue
    Garcia, Roel
    ANNALS OF NUCLEAR ENERGY, 2018, 115 : 105 - 115
  • [36] Performance of a High Speed and High Density Data Acquisition System for Multiple Gamma-ray Detection
    Kimura, Atsushi
    Toh, Yosuke
    Koizumi, Mitsuo
    Furutaka, Kazuyoshi
    Kin, Tadahiro
    Oshima, Masumi
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1382 - 1386
  • [37] A novel sorting algorithm and its application to a gamma-ray telescope asynchronous data acquisition system
    Colavita, A
    Mumolo, E
    Capello, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 394 (03): : 374 - 380
  • [38] Improvement of a high speed and high density data acquisition system for multiple gamma-ray detection
    Kimura, Atsushi
    Toh, Yosuke
    Koizumi, Mitsuo
    Furutaka, Kazuyoshi
    Kin, Tadahiro
    Oshima, Masumi
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 474 - 477
  • [40] High density and high cost performance data acquisition system for multiple gamma-ray detection
    Kimura, A
    Koizumi, M
    Toh, Y
    Osa, A
    Oshima, M
    Goto, J
    Arai, Y
    Sagara, M
    Iri, S
    Kobayashi, H
    Suzuki, Y
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1489 - 1493