Leak Test for Cryogenic Heat Exchanger

被引:0
|
作者
Baral, Dipika [1 ]
Tilva, Vidita [1 ]
Singh, Rohit [2 ]
机构
[1] Nirma Univ, I&C Engn Dept, Ahmadabad 382481, Gujarat, India
[2] Nutron Syst Pvt Ltd, Ahmadabad, Gujarat, India
关键词
DAQ; PLC; WinCC; SCADA; NI-LabVIEW;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A Cryogenic temperature control system based on temperature monitor having multiple channels has been used for recording and monitoring the various temperature in Cryogenic Heat exchanger which is further used for liquid helium test facility. The effectiveness of heat exchanger can be maintain by the temperature that will be measured at inlet and outlet of the prototype heat exchanger. The temperature range of the tested heat exchanger is 77 k to 300 k. This paper tells the crucial role of temperature in cryogenic system and describes the process. Various sensors has been placed in the system and different temperature readings has been taken in LabVIEW where it can be monitor and log the varying temperature value of a cryogenic heat exchanger with the help of data acquisition system (DAQ). Siemens PLC (Programmable logic control) S7 300 has been introduced for controlling the cryogenic heat exchanger process.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] DEVELOPMENT OF A LOW HEAT LEAK CFRP STAND FOR MIRI COOLER JT HEAT EXCHANGER STAGE
    Makowski, K. P.
    Larson, M. E.
    Loc, A. S.
    Zhang, B. X.
    Leland, R. S.
    Hayashi, B.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 1015 - +
  • [42] A new method for evaluating the heat leak of cryogenic vessels without exhaust gas
    Li, Zhengqing
    Wang, Xiaojun
    Han, Xianhu
    Cai, Yuhong
    Wang, Yi
    HELIYON, 2023, 9 (11)
  • [43] Heat leak of cryogenic pipe for superconducting dc power transmission line (SCDC)
    Yamaguchi, Sataro
    Kanda, Masae
    Ivanov, Yury
    32ND INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS2019), 2020, 1590
  • [44] LEAK DETECTION IN AN EXPERIMENTAL HEAT-EXCHANGER PROCESS - A MULTIPLE MODEL APPROACH
    LOPARO, KA
    BUCHNER, MR
    VASUDEVA, KS
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1991, 36 (02) : 167 - 177
  • [45] HEAT-EXCHANGE AND FLOW RESISTANCE OF A HAMPSON TYPE CRYOGENIC MICRO-HEAT-EXCHANGER
    BODIO, E
    ACTA PHYSICA POLONICA A, 1975, 48 (06) : 851 - 859
  • [46] Power consumption for a scraped-surface heat exchanger with a 'no-leak' reactor
    Altiokka, Mehmet R.
    Industrial and Engineering Chemistry Research, 1992, 31 (10): : 2385 - 2388
  • [47] Reliable leak detection in a heat exchanger of a sodium-cooled fast reactor
    Guepie, Blaise Kevin
    Grall-Maes, Edith
    Beauseroy, Pierre
    Nikiforov, Igor
    Michel, Frederic
    ANNALS OF NUCLEAR ENERGY, 2020, 142 (142)
  • [48] LEAK TESTING CRYOGENIC VESSELS
    ROEHRS, RJ
    MATERIALS EVALUATION, 1968, 26 (11) : 236 - &
  • [49] A numerical study on the internal heat leak mechanisms in a variable property three-stream heat exchanger
    Shafiei-alamooti, Yasser
    Ashrafizadeh, Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (08) : 1946 - 1963
  • [50] First Cryogenic Tests of Superfluid Helium Heat Exchanger for an Ultracold Neutron Source
    Lyamkin, V. A.
    Serebrov, A. P.
    Koptyukhov, A. O.
    ATOMIC ENERGY, 2023, 133 (3) : 187 - 190