Leak Test for Cryogenic Heat Exchanger

被引:0
|
作者
Baral, Dipika [1 ]
Tilva, Vidita [1 ]
Singh, Rohit [2 ]
机构
[1] Nirma Univ, I&C Engn Dept, Ahmadabad 382481, Gujarat, India
[2] Nutron Syst Pvt Ltd, Ahmadabad, Gujarat, India
关键词
DAQ; PLC; WinCC; SCADA; NI-LabVIEW;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A Cryogenic temperature control system based on temperature monitor having multiple channels has been used for recording and monitoring the various temperature in Cryogenic Heat exchanger which is further used for liquid helium test facility. The effectiveness of heat exchanger can be maintain by the temperature that will be measured at inlet and outlet of the prototype heat exchanger. The temperature range of the tested heat exchanger is 77 k to 300 k. This paper tells the crucial role of temperature in cryogenic system and describes the process. Various sensors has been placed in the system and different temperature readings has been taken in LabVIEW where it can be monitor and log the varying temperature value of a cryogenic heat exchanger with the help of data acquisition system (DAQ). Siemens PLC (Programmable logic control) S7 300 has been introduced for controlling the cryogenic heat exchanger process.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Heat exchange when a leak occurs into the insulating space of a cryogenic tank
    Domashenko, A.M.
    2005, Mashinostroeni
  • [32] Study on effect of liquid level on the heat leak into vertical cryogenic vessels
    Li, Yang
    Wang, Rongshun
    Wang, Caili
    CRYOGENICS, 2010, 50 (6-7) : 367 - 372
  • [33] HYDRODYNAMICS AND HEAT TRANSFER OF LIQUID NITROGEN LAMINAR FALLING FILMS IN CRYOGENIC HEAT EXCHANGER
    Xie Ying-Bai
    Tang Jian-Cheng
    Zhao Cheng
    Mai Ying-Cheng
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 9, PTS A-C, 2010, : 595 - 599
  • [35] Heat transfer and pressure drop in the main heat exchanger of a cryogenic mixed refrigerant cycle
    Gomse, D.
    Grohmann, S.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [36] EFFECT OF RANDOM PLUGGING ON PERFORMANCE OF MULTIPASSAGED CRYOGENIC HEAT-EXCHANGER
    HENDRICK.RB
    LASHMET, PK
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1972, 11 (01): : 53 - &
  • [37] Development of a high-effectiveness slotted plate cryogenic heat exchanger
    Sheehan, E.
    Pfotenhauer, J.
    Miller, F.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [38] Micro-structured heat exchanger for cryogenic mixed refrigerant cycles
    Gomse, D.
    Reiner, A.
    Rabsch, G.
    Gietzelt, T.
    Brandner, J. J.
    Grohmann, S.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [39] Influence of Frost Growth and Migration in Cryogenic Heat Exchanger on Air Refrigerator
    Yang, Shanju
    Liu, Zhan
    Fu, Bao
    Chen, Yu
    APPLIED SCIENCES-BASEL, 2019, 9 (04):
  • [40] CORROSION TEST METHODS FOR HEAT EXCHANGER APPLICATIONS
    WOLFE, W
    HAGER, SF
    MECHANICAL ENGINEERING, 1967, 89 (12) : 62 - &