A Cryogenic temperature control system based on temperature monitor having multiple channels has been used for recording and monitoring the various temperature in Cryogenic Heat exchanger which is further used for liquid helium test facility. The effectiveness of heat exchanger can be maintain by the temperature that will be measured at inlet and outlet of the prototype heat exchanger. The temperature range of the tested heat exchanger is 77 k to 300 k. This paper tells the crucial role of temperature in cryogenic system and describes the process. Various sensors has been placed in the system and different temperature readings has been taken in LabVIEW where it can be monitor and log the varying temperature value of a cryogenic heat exchanger with the help of data acquisition system (DAQ). Siemens PLC (Programmable logic control) S7 300 has been introduced for controlling the cryogenic heat exchanger process.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Emergency management of heat exchanger leak on cardiopulmonary bypass with hypothermia
    Gukop, P.
    Tiezzi, A.
    Mattam, K.
    Sarsam, M.
    PERFUSION-UK, 2015, 30 (08): : 694 - 697
  • [22] EXPERIMENTAL STUDY ON THE HEAT TRANSFER CHARACTERISTICS OF CRYOGENIC MICRO CHANNEL HEAT EXCHANGER
    Yoon, Seok Ho
    Kim, Duckjong
    Choi, Jun Seok
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 6: MICROCHANNELS, NANO, NANOFLUIDS, SPRAY COOLING, POROUS MEDIA, 2010, : 21 - 24
  • [23] A review on heat exchanger thermal hydraulic models for cryogenic applications
    Pacio, Julio Cesar
    Dorao, Carlos Alberto
    CRYOGENICS, 2011, 51 (07) : 366 - 379
  • [24] A cryogenic heat exchanger with bypass and throttling and its thermodynamic analysis
    Tao, X.
    Liu, D. L.
    Wang, L. Y.
    Shen, J.
    Gan, Z. H.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [25] Effect of fluid property variations on the effectiveness of a cryogenic heat exchanger
    Etagi, Anirudh
    Katte, Parinith
    Talya, Ananya
    Mishra, Ayushi
    Krishna, V.
    HEAT TRANSFER, 2023, 52 (06) : 4461 - 4486
  • [26] Design of a Cryogenic Helium Plate-Fin Heat Exchanger
    Hu, Z. J.
    Qiu, Y. N.
    Zhang, N.
    Li, Q.
    12TH CRYOGENICS 2012 IIR INTERNATIONAL CONFERENCE, 2012, : 413 - 416
  • [27] Reduction of heat leak in cryogenic system using Peltier current leads
    Hasegawa, Y
    Sato, K
    Okumura, H
    Nakamura, K
    Yamaguchi, S
    Miyake, K
    CRYOGENICS, 2002, 42 (08) : 495 - 500
  • [28] CRYOGENIC LEAK TEST PROCEDURE FOR A LARGE SUPERCONDUCTING CYCLOTRON HELIUM VESSEL
    MALLORY, ML
    HILBERT, HP
    LAUMER, HW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01): : 14 - 16
  • [29] ESTIMATION OF STEADY-STATE HEAT LEAK INTO CYLINDRICAL CRYOGENIC CONTAINERS
    MURTHY, SS
    KRISHNAMURTHY, MV
    CRYOGENICS, 1978, 18 (10) : 611 - 613
  • [30] HEAT EXCHANGE WHEN A LEAK OCCURS INTO THE INSULATING SPACE OF A CRYOGENIC TANK
    Domashenko, A. M.
    CHEMICAL AND PETROLEUM ENGINEERING, 2005, 41 (5-6) : 312 - 318