HIGH RESOLUTION X-RAY MICRO-CT OF ULTRA-THIN WALL SPACE COMPONENTS

被引:0
|
作者
Roth, D. J. [1 ]
Rauser, R. W. [2 ]
Bowman, R. R. [1 ]
Bonacuse, P. J. [1 ]
Martin, R. E. [3 ]
Locci, I. E. [2 ]
Kelley, M. [4 ]
机构
[1] NASA, Glenn Res Ctr, Cleveland, OH 44135 USA
[2] Univ Toledo, Toledo, OH 43606 USA
[3] Cleveland State Univ, Cleveland, OH 44115 USA
[4] NEURAL ID, Redwood City, CA 94065 USA
关键词
Nondestructive Evaluation (NDE); Computed Tomography; Imaging; X-ray Metallic Components; Thin Wall Inspection;
D O I
10.1063/1.14789101
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A high resolution micro-CT system has been assembled and is being used to provide optimal characterization for ultra-thin wall space components. The Glenn Research Center NDE Sciences Team, using this CT system, has assumed the role of inspection vendor for the Advanced Stirling Convertor (ASC) project at NASA. This article will discuss many aspects of the development of the CT scanning for this type of component, including CT system overview; inspection requirements; process development, software utilized and developed to visualize, process, and analyze results; calibration sample development; results on actual samples; correlation with optical/SEM characterization; CT modeling; and development of automatic flaw recognition software.
引用
收藏
页码:595 / 603
页数:9
相关论文
共 50 条
  • [41] X-RAY STANDING WAVES IN LSM FOR CHARACTERIZATION OF ULTRA-THIN FILMS
    ZHELUDEVA, SI
    KOVALCHUK, MV
    NOVIKOVA, NN
    SOSPHENOV, AN
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (4A) : A206 - A209
  • [42] X-ray diffraction analysis of YBaCuO ultra-thin film growth
    Linker, G
    Huttner, D
    Meyer, O
    Ohkubo, M
    Reiner, J
    JOURNAL OF ALLOYS AND COMPOUNDS, 1997, 251 (1-2) : 65 - 69
  • [43] Grazing incidence X-ray studies of ultra-thin Lumogen films
    Keough, S. J.
    Hanley, T. L.
    Wedding, A. B.
    Quinton, J. S.
    SURFACE SCIENCE, 2007, 601 (24) : 5744 - 5749
  • [44] Application of x-ray fluorescence spectrometry in characterization of high-k ultra-thin films
    Zhao, C
    Brijs, B
    Dortu, F
    DeGendt, S
    Caymax, M
    Heyns, M
    Besling, W
    Maes, JW
    ANALYTICAL AND DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS, DEVICES, AND PROCESSES, 2003, 2003 (03): : 243 - 251
  • [45] X-ray interferometry: Ultra high resolution astronomy
    Cash, W
    Shipley, A
    McEntaffer, R
    SOFT X-RAY AND EUV IMAGING SYSTEMS II, 2001, 4506 : 127 - 135
  • [46] Non-destructive, high-resolution X-ray micro-CT of a Hairy Stalagmite: investigating the structural details of a biogenic speleothem
    du Preez, G.
    du Plessis, A.
    de Beer, D.
    Forti, P.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2018, 15 (09) : 1843 - 1850
  • [47] Non-destructive, high-resolution X-ray micro-CT of a Hairy Stalagmite: investigating the structural details of a biogenic speleothem
    G. du Preez
    A. du Plessis
    D. de Beer
    P. Forti
    International Journal of Environmental Science and Technology, 2018, 15 : 1843 - 1850
  • [48] Data-Constrained Microstructure Characterization with Multispectrum X-Ray Micro-CT
    Mayo, Sheridan C.
    Tulloh, Andrew M.
    Trinchi, Adrian
    Yang, Sam Y. S.
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (03) : 524 - 530
  • [49] A reconstruction of the lophophore of Devonian rhynchonellids (Brachiopoda) by using X-Ray micro-CT
    A. V. Pakhnevich
    Paleontological Journal, 2017, 51 : 143 - 154
  • [50] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105