HIGH RESOLUTION X-RAY MICRO-CT OF ULTRA-THIN WALL SPACE COMPONENTS

被引:0
|
作者
Roth, D. J. [1 ]
Rauser, R. W. [2 ]
Bowman, R. R. [1 ]
Bonacuse, P. J. [1 ]
Martin, R. E. [3 ]
Locci, I. E. [2 ]
Kelley, M. [4 ]
机构
[1] NASA, Glenn Res Ctr, Cleveland, OH 44135 USA
[2] Univ Toledo, Toledo, OH 43606 USA
[3] Cleveland State Univ, Cleveland, OH 44115 USA
[4] NEURAL ID, Redwood City, CA 94065 USA
关键词
Nondestructive Evaluation (NDE); Computed Tomography; Imaging; X-ray Metallic Components; Thin Wall Inspection;
D O I
10.1063/1.14789101
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A high resolution micro-CT system has been assembled and is being used to provide optimal characterization for ultra-thin wall space components. The Glenn Research Center NDE Sciences Team, using this CT system, has assumed the role of inspection vendor for the Advanced Stirling Convertor (ASC) project at NASA. This article will discuss many aspects of the development of the CT scanning for this type of component, including CT system overview; inspection requirements; process development, software utilized and developed to visualize, process, and analyze results; calibration sample development; results on actual samples; correlation with optical/SEM characterization; CT modeling; and development of automatic flaw recognition software.
引用
收藏
页码:595 / 603
页数:9
相关论文
共 50 条
  • [1] The Critical Role of High Resolution X-ray Micro-computed Tomography for Ultra-thin Wall Space Component Characterization
    Roth, D. J.
    Rouser, R. W.
    Bowman, R. R.
    Martin, R. E.
    Koshti, A. M.
    Morgan, David S.
    MATERIALS EVALUATION, 2014, 72 (03) : 389 - 397
  • [2] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340
  • [3] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Elkhoury, Jean E.
    Shankar, Raji
    Ramakrishnan, T. S.
    TRANSPORT IN POROUS MEDIA, 2019, 129 (01) : 413 - 425
  • [4] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Jean E. Elkhoury
    Raji Shankar
    T. S. Ramakrishnan
    Transport in Porous Media, 2019, 129 : 413 - 425
  • [5] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [6] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [7] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [8] Ultra-Thin Silicon Nitride X-Ray Windows
    Torma, Pekka T.
    Sipila, Heikki J.
    Mattila, Marco
    Kostamo, Pasi
    Kostamo, Jari
    Kostamo, Esa
    Lipsanen, Harri
    Nelms, Nick
    Shortt, Brian
    Bavdaz, Marcos
    Laubis, Christian
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 1311 - 1314
  • [9] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [10] X-ray microtomography (micro-CT): a reference technology for high-resolution quantification of xylem embolism in trees
    Cochard, H.
    Delzon, S.
    Badel, E.
    PLANT CELL AND ENVIRONMENT, 2015, 38 (01): : 201 - 206