Improved free-air ionization chamber for the measurement of x-rays

被引:8
|
作者
Chen, WL [1 ]
Su, SH [1 ]
Su, LL [1 ]
Hwang, WS [1 ]
机构
[1] Inst Nucl Energy Res, Lungtan 325, Hsiang, Taiwan
关键词
D O I
10.1088/0026-1394/36/1/4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Based on an original design by F. H. Attix, an improved free-air ionization chamber was constructed at the National Radiation Standard Laboratory of the Institute of Nuclear Energy Research (INER, Taiwan), as the primary standard for x-rays generated at energy levels between 50 keV and 300 keV. Various improvements were made to the Attix design, including modifications of the chamber structure and the measurement technique. The changes include: (i) a three-section design with fixed central cylinder; (ii) thickening of the shielding box; (iii) a circuitous mechanism for the operational handle, to avoid unwanted scattering; (iv) a ruler mechanism to provide fine position control; and (v) increased thickness of the aluminium wall of the chamber. After initial experimental verification, a comparison with the National Institute of Standards and Technology (NIST, USA) using a transfer standard chamber yielded differences in calibration factors of less than 1%. In addition, the overall uncertainty for the x-ray measurement in terms of air kerma is less than 1% at the 95% confidence level. These results indicate that the improved free-air ionization chamber can serve as a primary standard at the NRSL.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [41] STANDARD FREE-AIR CHAMBER WITH MAGNETIC FIELD FOR X-OR GAMMA-RAYS UP TO ABOUT 50 MEV
    ZURICH, GJ
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 1963, 14 (02): : 195 - &
  • [42] Diaphragm correction factors for the FAC-IR-300 free-air ionization chamber
    Mohammadi, Seyed Mostafa
    Tavakoli-Anbaran, Hossein
    APPLIED RADIATION AND ISOTOPES, 2018, 132 : 178 - 180
  • [43] Free-air ionization chamber, FAC-IR-300, designed for medium energy X-ray dosimetry
    Mohammadi, S. M.
    Tavakoli-Anbaran, H.
    Zeinali, H. Z.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [44] ELECTRODE-EMISSION EFFECTS ON SATURATION CURRENT IN FREE-AIR IONIZATION-CHAMBER
    MAHESH, K
    MUSTAFA, SM
    NUCLEAR INSTRUMENTS & METHODS, 1978, 153 (2-3): : 473 - 476
  • [45] Ionization and heating by X-rays and cosmic rays
    Guedel, Manuel
    SUMMER SCHOOL PROTOPLANETARY DISKS: THEORY AND MODELING MEET OBSERVATIONS, 2015, 102
  • [46] Absolute measurement of photon flux using ionization chamber in (6∼20) keV synchrotron radiation X-rays
    Guo, Siming
    Wang, Peiwei
    Wang, Ji
    Li, Fan
    Wu, Jinjie
    Zhang, Jian
    X-RAY SPECTROMETRY, 2020, 49 (05) : 572 - 579
  • [47] IONIZATION CONTRIBUTION BY COSMIC X-RAYS
    MITRA, AP
    RAMANAMURTY, YV
    RADIO SCIENCE, 1972, 7 (01) : 67 - +
  • [48] Multiple ionization and the absorption of X-rays
    Richtmyer, FK
    PHILOSOPHICAL MAGAZINE, 1928, 6 (34): : 64 - 88
  • [49] MULTIPLE IONIZATION OF XE BY X-RAYS
    SHARKEY, TG
    VANBRUNT, RJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (11): : 1146 - 1146
  • [50] The ionization of noble gases by X-rays
    Wilhelmy, E.
    ZEITSCHRIFT FUR PHYSIK, 1933, 83 (5-6): : 341 - 350