Improved free-air ionization chamber for the measurement of x-rays

被引:8
|
作者
Chen, WL [1 ]
Su, SH [1 ]
Su, LL [1 ]
Hwang, WS [1 ]
机构
[1] Inst Nucl Energy Res, Lungtan 325, Hsiang, Taiwan
关键词
D O I
10.1088/0026-1394/36/1/4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Based on an original design by F. H. Attix, an improved free-air ionization chamber was constructed at the National Radiation Standard Laboratory of the Institute of Nuclear Energy Research (INER, Taiwan), as the primary standard for x-rays generated at energy levels between 50 keV and 300 keV. Various improvements were made to the Attix design, including modifications of the chamber structure and the measurement technique. The changes include: (i) a three-section design with fixed central cylinder; (ii) thickening of the shielding box; (iii) a circuitous mechanism for the operational handle, to avoid unwanted scattering; (iv) a ruler mechanism to provide fine position control; and (v) increased thickness of the aluminium wall of the chamber. After initial experimental verification, a comparison with the National Institute of Standards and Technology (NIST, USA) using a transfer standard chamber yielded differences in calibration factors of less than 1%. In addition, the overall uncertainty for the x-ray measurement in terms of air kerma is less than 1% at the 95% confidence level. These results indicate that the improved free-air ionization chamber can serve as a primary standard at the NRSL.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [21] Characterization of the new free-air primary standard for medium-energy X-rays at CMI
    Sochor, V
    Solc, J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [22] Characterization of the new free-air primary standard for low-energy X-rays at CMI
    Solc, Jaroslav
    Sochor, Vladimir
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 328 - 331
  • [23] Design Considerations for a Medium-Energy Free-Air Ionization Chamber
    King, E.
    Hull, J.
    Anderson, D.
    DeWerd, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E379 - E380
  • [24] Free-air ionization chambers
    Burns, D. T.
    Bueermann, L. B.
    METROLOGIA, 2009, 46 (02) : S9 - S23
  • [25] Design and preliminary test of a free-air ionization chamber for low-energy X-ray
    吴金杰
    杨元第
    王培玮
    陈靖
    柳加成
    中国物理C, 2011, 35 (06) : 576 - 579
  • [26] Design and preliminary test of a free-air ionization chamber for low-energy X-ray
    Wu Jin-Jie
    Yang Yuan-Di
    Wang Pei-Wei
    Chen Jing
    Liu Jia-Cheng
    CHINESE PHYSICS C, 2011, 35 (06) : 576 - 579
  • [27] Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber
    Yu Jili
    Wu Jinjie
    Liao Zhenyu
    Zhou Zhenjie
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (10) : 1466 - 1472
  • [28] Design of the free-air ionization chamber, FAC-IR-150, for X-ray dosimetry
    Mohammadi, Seyed Mostafa
    Tavakoli-Anbaran, Hossein
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 344 - 350
  • [29] Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
    Li, Fan
    Zhao, Yidong
    Wang, Peiwei
    Tang, Kun
    Zheng, Lei
    SENSORS, 2023, 23 (02)
  • [30] MEASUREMENT OF IONIZATION IN LIQUID ARGON DUE TO X-RAYS
    ULLMAIER, HA
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 95 - &